Hydrographic Cruise: 316N19871123

Date Start/End:
1987-11-23/1987-12-13
Chief Scientist:
Ship:
KNORR
Country:
US
Collections

Dataset

Files in the Dataset are the data for this cruise. They are updated when new data are submitted or as needed.

Download Entire Dataset Submit Data For This Cruise

Data History

  • Exchange, WOCE LV files online Dave Muus

    Date: 2011-12-23
    Data Type: Large Volume
    Action: Website Updated
    Note:
    Notes on SAVE Leg 1 large volume(GERARD & surface pump) sample data.    Dec 23, 2011     EXPOCODE 316N19871123
    
    1. Java OceanAtlas version 5.0.2 required to read Large Volume Exchange files using REVPRS and REVTMP in place of CTDPRS and CTDTMP.
       Unable to read Large Volume NetCDF files at this time.
    
    2. Pressure, temperature and salinities for Gerard barrels and attached Niskin bottle taken from ODF data (whprpasave1 dated Aug 25, 2005). 
    
    3. Data from Niskin bottle attached to Gerard barrels (Samples 40-54) merged from file SAVEsv.csv received from R. Key  Dec 9, 2010.
       Gerard Barrel data (Samples 81-92) merged from SAVElv.csv received from R. Key  Dec 9, 2010.
       Surface soak (Samples 99, Casts 9) data including temperatures and salinities merged from SAVElv.csv received from R. Key  Dec 9, 2010.
    
    4. No times available for surface soak samples. Used "0".
    
    5. Following samples have no pressures or temperatures. 
       The data contain only CFC-11 and CFC-12 data and were not used in the large volume data files.
       ODF Sample logs not located at this time.
    
                                    bottle
         STNNBR     CASTNO  BTLNBR  depth   REVPRS  REVTMP  SALNTY  SALNTYF OXYGEN  OXYGENF NITRAT  NITRATF NITRIT  NITRITF SILCAT  SILCATF PHSPHT  PHSPHTF CFC-11  CFC-11F CFC-12  CFC-12F
                                    meters  DBAR    ITS-68  PSS-78          UMOL/KG         UMOL/KG         UMOL/KG         UMOL/KG         UMOL/KG         PMOL/KG         PMOL/KG
            18	1	66  	-999    -999    -999    -999    9       -999	9	-999	2	-999	2	-999	9	-999	9	0.005	2	0.009	2
            18	1	70      -7      -999    -999    -999    9     	-999	9	-999	2	-999	2	-999	9	-999	9	0.009	2	0.012	2
            19	2	66	-999    -999	-999    -999    9       -999	9	-999	2	-999	2	-999	9	-999	9	0.016	2	-999	9
            42      2       56      -999    -999    -999    -999    9       -999    9       -999    2       -999    2       -999    9       -999    9       1.416   2       0.71    2
    
    6. Changed quality flags for Gerard cast Niskins bottle NITRAT and NITRIT from 2 to 9 for missing values.                                              
    
    7. Changed quality flags for following samples with missing values:                                              
       Station Cast Sample Parameter  from to
         11     3    90     RA-228     2    9
                     90     RA-8/6     1    9
         11     3    91     RA-228     2    9
                     91     RA-8/6     1    9
         15     1    83  Oxy&Nutrients 2    9
         15     1    84  Oxy&Nutrients 2    9
         15     1    85  Oxy&Nutrients 2    9
         15     1    86  Oxy&Nutrients 2    9
         21     3    87     RA-228     2    9
                     87     RA-8/6     1    9
         21     3    90     RA-228     2    9
                     90     RA-8/6     1    9
         24     3    89     RA-228     3    9
                     89     RA-8/6     1    9
         24     3    91     RA-228     2    9
                     91     RA-8/6     1    9
         24     1    83     RA-228     2    9
                     83     RA-8/6     1    9
         27     3    91     RA-228     3    9
                     91     RA-8/6     1    9
         27     1    83     RA-228     2    9
                     83     RA-8/6     1    9
         43     2    82     RA-228     3    9
                     82     RA-8/6     1    9
         43     2    84     RA-228     3    9
                     84     RA-8/6     1    9
    
    8. No THETA in SAVElv.csv for Surface Pump Samples, Cast 9s, Samples 99s. Pressure = 1dbar.
    					
  • Corrected files online Dave Muus

    Date: 2011-04-28
    Data Type: CTD
    Action: Website Update
    Note:
    Notes on corrections to SAVE Leg1 CTD files EXPOCODE 316N19871123   110426/dm
    
    Found following errors in WOCE format CTD files posted April 25, 2011:
    
    Station  11 Cast 2  Deepest pressure (3826.0db) values omitted. 
    Station  12 Cast 1  Deepest pressure (3762.0db) values omitted.
    Station  13 Cast 1  Deepest pressure (3070.0db) values omitted.
    Station  14 Cast 2  Deepest pressure (2284.0db) values omitted.
    Station  26 Cast 1  Deep pressure (5480.0 - 5518.0db) values omitted.
        Corrected WOCE, Exchange and NetCDF files.
    					
  • WOCE, Exchange, NetCDF files online Dave Muus

    Date: 2011-04-25
    Data Type: CTD
    Action: Website Update
    Note:
    Notes on Save Leg 1 CTD data.  EXPOCODE 316N19871123    110422/dm
    
    1. Made CTD data files in WOCE, Exchange and NetCDF formats.
       Data taken from ODF archives: file whprpasave1ctd, dated Aug 26, 2005
    					
  • New PDF and Text versions online Jerry Kappa

    Date: 2011-04-20
    Data Type: CrsRpt
    Action: Website Updated
  • Exchange, NetCDF, WOCE files online Dave Muus

    Date: 2011-04-08
    Data Type: BOT/SUM
    Action: Website Update
    Note:
    Notes on Save Leg 1 rosette sample data.    EXPOCODE 316N19871123   110406/dm
    
    1. Temperature, salinities, oxygen and nutrients taken from ODF data, whprpasave1, dated Aug 25, 2005.
    
    2. CFCs and CO2 data merged from file SAVEsv.csv received from R. Key  Dec 10, 2010.
       PCO2 values in file but no flags. Added flag 2 for all PCO2s.
     
    3. Station 16, Cast 1, Sample 16 684db: ODF deleted water samples "Lanyard hangup?"        
       Salinity & oxygen high, nutrients low.
       SAVEsv.csv TCARBN 127 low, PCO2 785 low. Deleted.
    
    4. Deleted Station 24 Cast 3 Bottle 9 from SAVEsv.csv file. Cast 3 is Gerard cast, Bottle 9 is rosette bottle. Only sample values are CFCs.
    
    5. CTDTMP units ITS-68 not ITS-90.
    
    6. Station 41, Cast 1, Sample 32 Reversing Pressure 550db low. Other values including Reversing temperature look okay. Changed flag from 2 to 4.