SAVE-4/HYDROS-2 R/V MELVILLE 7 DEC 1988 - 15 JAN 1989 20111214CCHDOSIODM SHIP/CRS WOCE CAST UTC EVENT POSITION UNC HT ABOVE WIRE MAX NO. OF EXPOCODE SECT STNNBR CASTNO TYPE DATE TIME CODE LATITUDE LONGITUDE NAV DEPTH BOTTOM OUT PRESS BOTTLES PARAMETERS COMMENTS ------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------- 318M19881207 SAVE4 171 1 ROS 120988 2133 BO 46 59.50 S 60 49.20 W GPS 204 7 -9 209 17 1-6 CTD#2 24 bottle 318M19881207 SAVE4 171 2 LVS 120988 2342 MR 46 58.80 S 60 49.10 W GPS 204 10 190 198 9 1 4 barrel 318M19881207 SAVE4 171 9 USW 120988 0 UN 46 59.5 S 60 49.2 W GPS 208 Surface Radium Pump Sample 318M19881207 SAVE4 172 1 ROS 121088 0306 BO 46 59.20 S 60 23.20 W GPS 531 12 -9 525 12 1-6 CTD#2 12 bottle 318M19881207 SAVE4 172 9 USW 121088 0 UN 46 58.8 S 60 23.22 W GPS 521 Surface Radium Pump Sample 318M19881207 SAVE4 173 1 ROS 121088 0748 BO 47 0.40 S 59 34.60 W GPS 1001 10 -9 986 12 1-6 CTD#2 12 bottle 318M19881207 SAVE4 173 2 LVS 121088 1105 MR 46 59.40 S 59 33.20 W GPS 1027 25 1000 979 15 1 7 barrel 318M19881207 SAVE4 173 9 USW 121088 0 UN 47 0 S 59 34.62 W GPS 982 Surface Radium Pump Sample 318M19881207 SAVE4 174 1 ROS 121088 1452 BO 46 58.30 S 59 8.80 W GPS 1550 18 -9 1529 18 1-6 CTD#2 18 bottle 318M19881207 SAVE4 174 9 USW 121088 0 UN 46 58.2 S 59 8.82 W GPS 1526 Surface Radium Pump Sample 318M19881207 SAVE4 175 1 ROS 121088 2015 BO 46 59.30 S 58 29.80 W GPS 2573 10 -9 2568 18 1-6 CTD#2 18 bottle 318M19881207 SAVE4 175 9 USW 121088 0 UN 46 58.8 S 58 29.82 W GPS 2542 Surface Radium Pump Sample 318M19881207 SAVE4 176 1 LVS 121188 0100 MR 46 58.40 S 58 11.70 W GPS 3067 24 3040 3046 13 1 Deep, 6 barrel 318M19881207 SAVE4 176 2 ROS 121188 0408 BO 46 58.30 S 58 12.10 W GPS 3037 10 -9 3047 18 1-6 CTD#2 18 bottle 318M19881207 SAVE4 176 3 LVS 121188 0746 MR 46 58.50 S 58 11.70 W GPS -9 -9 1500 1493 18 1 Shallow 9 barrel 318M19881207 SAVE4 176 9 USW 121188 0 UN 46 58.2 S 58 12.12 W GPS 3006 Surface Radium Pump Sample 318M19881207 SAVE4 177 1 ROS 121188 1230 BO 47 1.00 S 57 47.50 W GPS 3812 12 -9 3841 36 1-6 CTD#2 318M19881207 SAVE4 177 9 USW 121188 0 UN 47 0.6 S 57 47.52 W GPS 3787 Surface Radium Pump Sample 318M19881207 SAVE4 178 1 LVS 121188 1818 MR 47 1.40 S 57 14.30 W GPS -9 -9 133 118 12 1 Argon 6 barrel 318M19881207 SAVE4 178 4 ROS 121188 2136 BO 47 3.40 S 57 12.50 W GPS 4049 24 -9 4078 25 1-6 CTD#2 24 bottle 318M19881207 SAVE4 178 9 USW 121188 0 UN 47 3 S 57 12.48 W GPS 4027 Surface Radium Pump Sample 318M19881207 SAVE4 179 1 ROS 121288 0529 BO 46 59.00 S 56 40.00 W GPS 4372 12 -9 4422 36 1-6 CTD#2 318M19881207 SAVE4 179 9 USW 121288 0 UN 46 58.8 S 56 40.02 W GPS 4355 Surface Radium Pump Sample 318M19881207 SAVE4 180 1 LVS 121288 1321 MR 47 0.20 S 55 58.00 W GPS 5206 20 5243 5294 18 1 Deep 9 barrel 318M19881207 SAVE4 180 2 ROS 121288 1849 BO 47 1.00 S 55 56.30 W GPS 5237 12 -9 5336 36 1-6 CTD#2 318M19881207 SAVE4 180 3 LVS 121288 2345 MR 47 2.10 S 55 55.50 W GPS -9 -9 2205 2202 19 1 Shallow 9 barrel 318M19881207 SAVE4 180 4 LVS 121388 0406 MR 47 2.60 S 55 54.70 W GPS 5246 110 5175 5212 14 1 Argon 7 barrel 318M19881207 SAVE4 180 9 USW 121288 0 UN 47 0.6 S 55 56.28 W GPS 5240 Surface Radium Pump Sample 318M19881207 SAVE4 181 1 ROS 121388 1139 BO 46 59.80 S 55 8.60 W GPS 5711 12 -9 5840 36 1-6 CTD#2 318M19881207 SAVE4 181 9 USW 121388 0 UN 46 59.4 S 55 8.58 W GPS 5733 Surface Radium Pump Sample 318M19881207 SAVE4 182 1 ROS 121388 1949 BO 46 59.40 S 54 13.90 W GPS 5956 14 -9 6104 36 1-6 CTD#2 318M19881207 SAVE4 182 9 USW 121388 0 UN 46 59.4 S 54 13.92 W GPS 5987 Surface Radium Pump Sample 318M19881207 SAVE4 183 1 ROS 121488 0543 BO 47 3.40 S 52 53.70 W GPS 6064 12 -9 6226 36 1-6 CTD#2 318M19881207 SAVE4 183 9 USW 121488 0 UN 47 3 S 52 53.7 W GPS 6099 Surface Radium Pump Sample 318M19881207 SAVE4 184 1 LVS 121488 1643 MR 46 59.20 S 51 26.70 W GPS 6061 16 6130 6202 18 1 Deep 9 barrel 318M19881207 SAVE4 184 2 ROS 121488 2221 BO 46 59.30 S 51 29.50 W GPS 6061 15 -9 6225 36 1-6 CTD#2 318M19881207 SAVE4 184 3 LVS 121588 0337 MR 46 57.20 S 51 29.40 W GPS -9 -9 2512 2529 18 1 Shallow 9 barrel 318M19881207 SAVE4 184 9 USW 121488 0 UN 46 58.8 S 51 29.52 W GPS 6095 Surface Radium Pump Sample 318M19881207 SAVE4 185 1 ROS 121588 1402 BO 47 1.60 S 49 54.50 W GPS 6064 12 -9 6237 36 1-6 CTD#2 318M19881207 SAVE4 185 9 USW 121588 0 UN 47 1.2 S 49 54.48 W GPS 6100 Surface Radium Pump Sample 318M19881207 SAVE4 186 1 ROS 121688 0045 BO 46 59.60 S 48 31.00 W GPS 5903 14 -9 6061 36 1-6 CTD#1 318M19881207 SAVE4 186 9 USW 121688 0 UN 46 59.4 S 48 31.02 W GPS 5932 Surface Radium Pump Sample 318M19881207 SAVE4 187 1 LVS 121688 1258 MR 46 59.60 S 47 0.40 W GPS 5764 13 5820 5885 18 1-6 Deep 9 barrel 318M19881207 SAVE4 187 2 ROS 121688 1805 BO 47 0.10 S 47 0.30 W GPS 5771 13 -9 5927 36 1-6 CTD#1 Keeling 318M19881207 SAVE4 187 3 LVS 121688 2230 MR 47 0.90 S 47 0.50 W GPS -9 -9 1812 1805 18 1-6 Shallow 9 barrel 318M19881207 SAVE4 187 9 USW 121688 0 UN 47 0 S 47 0.3 W GPS 5802 Surface Radium Pump Sample 318M19881207 SAVE4 188 1 ROS 121788 0933 BO 47 0.90 S 45 6.30 W GPS 5493 13 -9 5607 36 1-6 CTD#1 318M19881207 SAVE4 188 9 USW 121788 0 UN 47 0.6 S 45 6.3 W GPS 5503 Surface Radium Pump Sample 318M19881207 SAVE4 189 1 ROS 121788 2024 BO 47 0.20 S 43 11.30 W GPS 5627 13 -9 5769 36 1-6 CTD#1 318M19881207 SAVE4 189 2 LVS 121888 0042 MR 47 1.50 S 43 8.40 W GPS -9 -9 3722 3730 14 1 Argon 7 barrel 318M19881207 SAVE4 189 9 USW 121788 0 UN 47 0 S 43 11.28 W GPS 5649 Surface Radium Pump Sample 318M19881207 SAVE4 190 1 LVS 121888 1243 MR 47 2.00 S 41 15.60 W GPS 5857 12 5920 5986 18 1-6 Deep 9 barrel 318M19881207 SAVE4 190 2 ROS 121888 1857 BO 47 3.50 S 41 13.50 W GPS 5859 18 -9 5996 36 1-6 CTD#1 Keeling 318M19881207 SAVE4 190 3 LVS 121888 2320 MR 47 3.30 S 41 9.90 W GPS -9 -9 2390 2388 18 1-6 Shallow 9 barrel 318M19881207 SAVE4 190 4 LVS 121988 0424 MR 47 4.30 S 41 6.30 W GPS -9 -9 4508 -9 0 Argon 6 barrel-no samples 318M19881207 SAVE4 190 9 USW 121888 0 UN 47 3 S 41 13.5 W GPS 5881 Surface Radium Pump Sample 318M19881207 SAVE4 191 1 LVS 121988 1722 MR 47 1.20 S 39 24.20 W GPS -9 -9 4532 4566 14 1 Argon 7 barrel 318M19881207 SAVE4 191 2 ROS 121988 2233 BO 47 1.30 S 39 26.50 W GPS 5570 13 -9 5656 36 1-6 CTD#1 318M19881207 SAVE4 191 3 LVS 122088 0241 MR 47 2.30 S 39 27.40 W GPS -9 -9 382 365 14 1 Argon 7 barrel 318M19881207 SAVE4 191 9 USW 121988 0 UN 47 1.2 S 39 26.52 W GPS 5582 Surface Radium Pump Sample 318M19881207 SAVE4 192 1 ROS 122088 1228 BO 46 58.20 S 37 44.20 W GPS 5824 12 -9 5967 36 2-6 CTD#1 318M19881207 SAVE4 192 2 LVS 122088 1617 MR 46 55.80 S 37 44.40 W GPS -9 -9 1490 1478 14 1 Argon 7 barrel 318M19881207 SAVE4 193 1 LVS 122288 0435 MR 46 55.90 S 32 30.70 W GPS 5299 766 4560 4586 18 1 Deep 9 barrel 318M19881207 SAVE4 193 2 ROS 122288 0920 BO 46 53.70 S 32 30.90 W GPS 5299 10 -9 5402 36 1-6 CTD#1 318M19881207 SAVE4 193 3 LVS 122288 1435 MR 46 52.20 S 32 31.10 W GPS 5279 182 5136 4862 18 1 Dp+sh Pretrip 9 bls 2 318M19881207 SAVE4 193 9 USW 122288 0 UN 46 53.4 S 32 30.9 W GPS 5304 Surface Radium Pump Sample 318M19881207 SAVE4 194 1 ROS 122388 0251 BO 47 2.50 S 30 41.70 W GPS 5058 10 -9 5151 36 2-6 CTD#1 318M19881207 SAVE4 195 1 ROS 122388 1425 BO 46 57.70 S 28 56.70 W GPS 4677 11 -9 4810 36 2-6 CTD#1 318M19881207 SAVE4 196 1 ROS 122488 0310 BO 46 59.50 S 27 3.60 W GPS 4634 13 -9 4715 36 2-6 CTD#1 318M19881207 SAVE4 196 9 USW 122488 0 UN 46 59.4 S 27 3.6 W GPS 4628 Surface Radium Pump Sample 318M19881207 SAVE4 197 1 ROS 122488 1329 BO 47 0.60 S 25 16.90 W GPS 4363 12 -9 4420 36 2-6 CTD#1 318M19881207 SAVE4 197 9 USW 122488 0 UN 47 0.6 S 25 16.92 W GPS 4346 Surface Radium Pump Sample 318M19881207 SAVE4 198 1 LVS 122588 0128 MR 46 59.80 S 23 28.50 W GPS 4333 18 4350 4361 19 1 Deep 9 barrel 318M19881207 SAVE4 198 2 ROS 122588 0600 BO 46 59.20 S 23 28.30 W GPS 4334 15 -9 4386 36 2-6 CTD#1 318M19881207 SAVE4 198 4 LVS 122588 1202 MR 46 58.40 S 23 25.80 W GPS -9 -9 1700 1561 18 1 Shallow 9 bls Pretrip 318M19881207 SAVE4 198 9 USW 122588 0 UN 46 58.8 S 23 28.32 W GPS 4316 Surface Radium Pump Sample 318M19881207 SAVE4 199 1 ROS 122688 2109 BO 46 57.70 S 19 33.10 W GPS 3970 15 -9 3998 36 2-6 CTD#1 318M19881207 SAVE4 199 2 LVS 122788 0020 MR 46 55.80 S 19 31.40 W GPS 3898 -9 382 368 18 1 Argon 9 barrel 318M19881207 SAVE4 199 9 USW 122688 0 UN 46 57.6 S 19 33.12 W GPS 3946 Surface Radium Pump Sample 318M19881207 SAVE4 200 1 ROS 122788 1021 BO 45 56.70 S 18 20.50 W GPS 3796 14 -9 3829 36 1-6 CTD#1 318M19881207 SAVE4 200 9 USW 122788 0 UN 45 56.4 S 18 20.52 W GPS 3777 Surface Radium Pump Sample 318M19881207 SAVE4 201 1 ROS 122788 2059 BO 44 51.20 S 17 16.70 W GPS 3269 11 -9 3325 37 1-6 CTD#1 318M19881207 SAVE4 201 9 USW 122788 0 UN 44 51 S 17 16.68 W GPS 3274 Surface Radium Pump Sample 318M19881207 SAVE4 202 1 ROS 122888 0814 BO 43 44.60 S 16 5.30 W GPS 3916 11 -9 4067 37 1-6 CTD#1 318M19881207 SAVE4 202 9 USW 122888 0 UN 43 44.4 S 16 5.28 W GPS 3999 Surface Radium Pump Sample 318M19881207 SAVE4 203 1 LVS 122888 1934 MR 42 43.90 S 14 59.10 W GPS 3719 28 3700 3703 19 1 Deep 9 barrel 318M19881207 SAVE4 203 2 ROS 122888 2302 BO 42 45.20 S 14 58.00 W GPS 3051 14 -9 3103 36 1-6 CTD#1 318M19881207 SAVE4 203 3 LVS 122988 0202 MR 42 46.00 S 14 55.80 W GPS -9 -9 1315 1186 16 1 Shallow 9 barrel Pretrip 318M19881207 SAVE4 203 9 USW 122888 0 UN 42 45 S 14 58.02 W GPS 3644 Surface Radium Pump Sample 318M19881207 SAVE4 204 1 ROS 122988 1035 BO 41 54.90 S 14 18.20 W GPS 3206 11 -9 3231 29 1-6 CTD#1 28 bottle 318M19881207 SAVE4 204 9 USW 122988 0 UN 41 54.6 S 14 18.18 W GPS 3189 Surface Radium Pump Sample 318M19881207 SAVE4 205 1 ROS 122988 1935 BO 41 7.30 S 13 29.90 W GPS 3023 15 -9 3039 25 1-6 CTD#1 24 bottle 318M19881207 SAVE4 205 9 USW 122988 0 UN 41 7.2 S 13 29.88 W GPS 3005 Surface Radium Pump Sample 318M19881207 SAVE4 206 1 ROS 123088 0813 BO 40 3.20 S 12 29.20 W GPS 3247 13 -9 3264 36 1-6 CTD#1 318M19881207 SAVE4 206 2 LVS 123088 1147 MR 40 4.20 S 12 26.90 W GPS 3231 -9 1551 1425 19 1 Shallow 9 barrel Pretrip 318M19881207 SAVE4 206 9 USW 123088 0 UN 40 3 S 12 29.22 W GPS 3230 Surface Radium Pump Sample 318M19881207 SAVE4 207 1 ROS 123188 0103 BO 38 49.30 S 11 25.40 W GPS 2972 15 -9 3145 25 1-6 CTD#1 24 bottle 318M19881207 SAVE4 207 9 USW 123188 0 UN 38 49.2 S 11 25.38 W GPS 3100 Surface Radium Pump Sample 318M19881207 SAVE4 208 1 ROS 123188 1447 BO 37 30.00 S 10 8.80 W GPS 3293 14 -9 3308 26 1-6 CTD#1 25 bottle 318M19881207 SAVE4 208 9 USW 123188 0 UN 37 30 S 10 8.82 W GPS 3277 Surface Radium Pump Sample 318M19881207 SAVE4 209 1 LVS 010189 0303 MR 36 15.80 S 9 7.00 W GPS 3720 16 3740 3762 19 1 Deep 9 barrel 318M19881207 SAVE4 209 2 ROS 010189 0647 BO 36 14.70 S 9 8.30 W GPS 3705 12 -9 3763 36 1-6 CTD#1 318M19881207 SAVE4 209 3 LVS 010189 0955 MR 36 13.50 S 9 8.70 W GPS 3735 -9 1545 1501 18 1 Shallow 9 barrel 318M19881207 SAVE4 209 9 USW 010189 0 UN 36 14.4 S 09 8.28 W GPS 3706 Surface Radium Pump Sample 318M19881207 SAVE4 210 1 ROS 010189 2132 BO 35 10.40 S 8 8.90 W GPS 3862 14 -9 3865 36 1-6 CTD#2 318M19881207 SAVE4 210 2 LVS 010289 0043 MR 35 10.00 S 8 7.20 W GPS 3821 -9 874 822 19 1 Argon 9 barrel 318M19881207 SAVE4 210 9 USW 010189 0 UN 35 10.2 S 08 8.88 W GPS 3862 Surface Radium Pump Sample 318M19881207 SAVE4 211 1 LVS 010289 1114 MR 34 4.50 S 7 11.30 W GPS 3991 -9 3068 3028 13 1 Argon 7 barrel 1 No trip 318M19881207 SAVE4 211 2 ROS 010289 1449 BO 34 3.00 S 7 10.00 W GPS 4042 14 -9 4105 36 1-6 CTD#1 318M19881207 SAVE4 211 9 USW 010289 0 UN 34 3 S 07 10.02 W GPS 4045 Surface Radium Pump Sample 318M19881207 SAVE4 212 1 LVS 010389 0321 MR 33 1.50 S 6 21.60 W GPS 4186 15 4215 4243 19 1 Deep 9 barrel 318M19881207 SAVE4 212 2 ROS 010389 0720 BO 33 3.30 S 6 20.60 W GPS 4179 9 -9 4252 36 1-6 CTD#1 318M19881207 SAVE4 212 3 LVS 010389 1053 MR 33 3.80 S 6 19.90 W GPS 4112 -9 1746 1701 18 1 Shallow 9 barrel 318M19881207 SAVE4 212 9 USW 010389 0 UN 33 3 S 06 20.58 W GPS 4185 Surface Radium Pump Sample 318M19881207 SAVE4 213 1 ROS 010389 2116 BO 31 59.80 S 5 31.00 W GPS 4455 14 -9 4531 37 1-6 CTD#1 318M19881207 SAVE4 213 9 USW 010389 0 UN 31 59.4 S 05 31.02 W GPS 4467 Surface Radium Pump Sample 318M19881207 SAVE4 214 1 ROS 010489 0840 BO 31 0.30 S 4 38.20 W GPS 4472 3 -9 4560 37 1-6 CTD#1 318M19881207 SAVE4 214 9 USW 010489 0 UN 31 0 S 04 38.22 W GPS 4484 Surface Radium Pump Sample 318M19881207 SAVE4 215 1 LVS 010489 1932 MR 29 59.50 S 3 48.30 W GPS 4838 24 4875 4918 15 1 Argon 7 barrel 318M19881207 SAVE4 215 2 ROS 010489 2350 BO 29 58.30 S 3 47.60 W GPS 4097 20 -9 4153 36 1-6 CTD#1 318M19881207 SAVE4 215 9 USW 010489 0 UN 29 58.2 S 03 47.58 W GPS 4833 Surface Radium Pump Sample 318M19881207 SAVE4 216 1 ROS 010589 0939 BO 30 1.10 S 2 30.00 W GPS 4426 11 -9 4543 37 1-6 CTD#1 318M19881207 SAVE4 216 9 USW 010589 0 UN 30 0.6 S 02 30 W GPS 4468 Surface Radium Pump Sample 318M19881207 SAVE4 217 1 LVS 010589 1956 MR 30 0.00 S 1 14.50 W GPS 4746 28 4770 4823 19 1 Deep 9 barrel 318M19881207 SAVE4 217 2 ROS 010689 0022 BO 30 0.10 S 1 14.70 W GPS 4744 10 -9 4839 36 1-6 CTD#1 318M19881207 SAVE4 217 3 LVS 010689 0414 MR 29 59.70 S 1 15.90 W GPS 4739 -9 2301 2299 18 1 Shallow 9 barrel 318M19881207 SAVE4 217 9 USW 010689 0 UN 30 0 S 01 14.7 W GPS 4763 Surface Radium Pump Sample 318M19881207 SAVE4 218 1 ROS 010689 1329 BO 30 0.40 S 0 3.60 W GPS 4232 7 -9 4468 37 1-6 CTD#2 prt-1 318M19881207 SAVE4 218 9 USW 010689 0 UN 30 0 S 00 3.6 W GPS 4395 Surface Radium Pump Sample 318M19881207 SAVE4 219 1 ROS 010689 2145 BO 29 59.90 S 1 0.50 E GPS 3110 12 -9 3135 25 1-6 CTD#1 24 bottle 318M19881207 SAVE4 219 9 USW 010689 0 UN 29 59.4 S 01 0.48 E GPS 3101 Surface Radium Pump Sample 318M19881207 SAVE4 220 1 ROS 010789 0538 BO 29 59.30 S 2 0.60 E GPS 3866 8 -9 3928 37 1-6 CTD#1 318M19881207 SAVE4 220 9 USW 010789 0 UN 29 58.8 S 02 0.6 E GPS 3869 Surface Radium Pump Sample 318M19881207 SAVE4 221 1 ROS 010789 1714 BO 30 0.80 S 3 42.00 E GPS 4732 17 -9 4815 37 1-6 CTD#1 318M19881207 SAVE4 221 9 USW 010789 0 UN 30 0.6 S 03 42 E GPS 4746 Surface Radium Pump Sample 318M19881207 SAVE4 222 1 LVS 010889 0149 MR 29 59.70 S 4 28.70 E GPS 4799 19 4840 4879 19 1 Deep 9 barrel 318M19881207 SAVE4 222 2 ROS 010889 0600 BO 29 58.70 S 4 26.50 E GPS 4921 9 -9 5029 36 1-6 CTD#1 318M19881207 SAVE4 222 3 LVS 010889 0919 MR 29 59.60 S 4 26.30 E GPS 4903 -9 1885 1878 18 1 Shallow 9 barrel 318M19881207 SAVE4 222 9 USW 010889 0 UN 29 58.2 S 04 26.52 E GPS 4941 Surface Radium Pump Sample 318M19881207 SAVE4 223 1 ROS 010889 2045 BO 30 0.40 S 6 1.10 E GPS 5151 12 -9 5269 37 1-6 CTD#1 318M19881207 SAVE4 223 9 USW 010889 0 UN 30 0 S 06 1.08 E GPS 5176 Surface Radium Pump Sample 318M19881207 SAVE4 224 1 ROS 010989 0519 BO 29 58.30 S 6 56.90 E GPS 5096 7 -9 5220 37 1-6 CTD#1 318M19881207 SAVE4 224 2 LVS 010989 1005 MR 29 57.90 S 6 59.00 E GPS 5089 20 5145 5200 18 1 Argon 9 barrel 318M19881207 SAVE4 224 9 USW 010989 0 UN 29 58.2 S 06 56.88 E GPS 5126 Surface Radium Pump Sample 318M19881207 SAVE4 225 1 LVS 010989 2312 MR 30 0.30 S 8 29.60 E GPS 4931 22 4975 5020 19 1 Deep 9 barrel 318M19881207 SAVE4 225 2 ROS 011089 0338 BO 30 1.70 S 8 28.00 E GPS 4940 10 -9 5047 36 1-6 CTD#1 318M19881207 SAVE4 225 3 LVS 011089 0705 MR 30 2.60 S 8 29.00 E GPS -9 -9 1728 1681 18 1 Shallow 9 barrel 318M19881207 SAVE4 225 9 USW 111089 0 UN 30 1.2 S 08 28.02 E GPS 4959 Surface Radium Pump Sample 318M19881207 SAVE4 226 1 LVS 011089 1424 MR 30 1.30 S 9 30.30 E GPS 4851 -9 726 713 19 1 Argon 9 barrel 318M19881207 SAVE4 226 2 ROS 011089 1709 BO 30 1.30 S 9 29.80 E GPS 4902 12 -9 5001 36 1-6 CTD#1 318M19881207 SAVE4 226 9 USW 111089 0 UN 30 1.2 S 09 29.82 E GPS 4920 Surface Radium Pump Sample 318M19881207 SAVE4 227 1 ROS 011189 0240 BO 29 59.70 S 10 33.30 E GPS 4561 11 -9 4640 37 1-6 CTD#1 318M19881207 SAVE4 227 9 USW 111189 0 UN 29 59.4 S 10 33.3 E GPS 4569 Surface Radium Pump Sample 318M19881207 SAVE4 228 1 ROS 011189 0946 BO 30 1.50 S 11 15.70 E GPS 4194 12 -9 4252 37 1-6 CTD#1 318M19881207 SAVE4 228 9 USW 111189 0 UN 30 1.2 S 11 15.72 E GPS 4194 Surface Radium Pump Sample 318M19881207 SAVE4 229 1 ROS 011189 1611 BO 29 58.50 S 11 58.60 E GPS 3948 9 -9 4006 37 1-6 CTD#1 318M19881207 SAVE4 229 9 USW 111189 0 UN 29 58.2 S 11 58.62 E GPS 3945 Surface Radium Pump Sample 318M19881207 SAVE4 230 1 LVS 011189 2230 MR 30 0.70 S 12 23.50 E GPS 3702 20 3720 3744 19 1 Deep 9 barrel 318M19881207 SAVE4 230 2 ROS 011289 0150 BO 30 0.70 S 12 22.50 E GPS 3720 10 -9 3764 36 1-6 CTD#1 318M19881207 SAVE4 230 3 LVS 011289 0450 MR 29 59.60 S 12 20.90 E GPS 3731 -9 1591 1588 18 1 Shallow 9 barrel 318M19881207 SAVE4 230 9 USW 111289 0 UN 30 0.6 S 12 22.5 E GPS 3713 Surface Radium Pump Sample 318M19881207 SAVE4 231 1 LVS 011289 1153 MR 30 1.90 S 13 5.40 E GPS 3014 27 3003 3012 15 1 Argon 7 barrel 318M19881207 SAVE4 231 2 ROS 011289 1448 BO 30 2.20 S 13 4.80 E GPS 3026 13 -9 3045 24 1-6 CTD#1 24 bottle 318M19881207 SAVE4 231 9 USW 111289 0 UN 30 1.8 S 13 4.8 E GPS 3012 Surface Radium Pump Sample 318M19881207 SAVE4 232 1 ROS 011289 2139 BO 29 59.50 S 13 48.70 E GPS 2579 10 -9 2582 25 1-6 CTD#1 24 bottle 318M19881207 SAVE4 232 9 USW 111289 0 UN 29 59.4 S 13 48.72 E GPS 2563 Surface Radium Pump Sample 318M19881207 SAVE4 233 1 ROS 011389 0159 BO 29 58.50 S 14 6.20 E GPS 1775 8 -9 1775 24 1-6 CTD#1 24 bottle 318M19881207 SAVE4 233 2 LVS 011389 0416 MR 29 58.90 S 14 4.40 E GPS 1862 378 1494 1483 19 1 Shallow 9 barrel 318M19881207 SAVE4 233 9 USW 111389 0 UN 29 58.2 S 14 6.18 E GPS 1760 Surface Radium Pump Sample 318M19881207 SAVE4 234 1 ROS 011389 0903 BO 29 59.90 S 14 38.80 E GPS 507 5 -9 510 18 1-6 CTD#1 19 bottle 318M19881207 SAVE4 234 9 USW 111389 0 UN 29 59.4 S 14 38.82 E GPS 507 Surface Radium Pump Sample 318M19881207 SAVE4 235 1 ROS 011389 1336 BO 29 59.80 S 15 20.80 E GPS 222 10 -9 219 9 1-6 CTD#1 8 bottle 318M19881207 SAVE4 235 2 LVS 011389 1442 MR 30 0.00 S 15 21.70 E GPS 222 20 220 210 8 1 Shallow 4 barrel 318M19881207 SAVE4 235 9 USW 111389 0 UN 29 59.4 S 15 20.82 E GPS 224 Surface Radium Pump Sample