Cruise Report for the 2021 Reoccupation of A22 ********************************************** GO-SHIP A22 2021 Hydrographic Program ===================================== Cruise Scientific Objectives ---------------------------- Viviane Menezes The A22 2021 cruise aboard the UNOLS vessel R/V Thomas G. Thompson was undertaken as part of the US GO-SHIP (Global Ocean Ship-based Hydrographic Investigations Program), a major contributor to international GO-SHIP. The program’s overall objective is to collect quasi-decadal, highly accurate, surface-to-bottom, coast-to-coast, physical, and chemical oceanic observations. These measurements are essential to monitoring long-term changes in heat, freshwater, carbon, oxygen, and other tracers in the global ocean– the main reservoir in the Earth System. The A22 meridional transect spans the western North Atlantic from the tropics to the subtropics and is the only GO-SHIP transect in the Caribbean Sea. This year, the A22 worked from South America’s continental shelf break, near Aruba, to Puerto Rico and thence northwards to Bermuda along the 66o W meridian. From Bermuda, the transect stretched to the continental shelf south of Woods Hole, following the Line W path (scienceweb.whoi.edu/linew/index.php). This is the first reoccupation of Line W after the end of that program in 2014, whose objective was monitoring the deep limb of the Atlantic Meridional Overturning Circulation (AMOC). Along the way, the A22 transect crossed major western boundary currents systems: the Caribbean Current, the Gulf Stream, and the North Atlantic Deep Western Boundary Current (DWBC) at different latitudes. The latter two are primary conduits of the AMOC. Although the A22 transect has been slightly modified over the years, this was the fourth reoccupation of this line in the last three decades. The A22 was first occupied in 1997 (79 stations; R/V Knorr) during WOCE (World Ocean Circulation Experiment), then in 2003 (82 stations; R/V Knorr) and 2012 (81 stations; R/V Atlantis) as part of the CLIVAR (Climate Variability and Predictability). In 2021, 90 CTD/LADCP/rosette stations were performed over the course of 27-days during boreal spring (20 April - 16 May 2021). Stations were nominally spaced by about 30 nm (50 km) in the open-ocean but closer (<= 15 nm) at boundary currents and major topographic features. At each station, a suite of surface to bottom vertical profiles was collected using electronic sensors (CTDO, LADCPS, chi-pods, transmissometer, UVP (Underwater Vision Profile)), and 36 Niskin bottles for sampling water at discrete vertical levels. Data collected during the A22 2021 were (some samplings will be processed in labs onshore): * Pressure, temperature, salinity, dissolved oxygen * Fluorescence, shear and micro-scale temperature * Current velocities from lowered and shipboard ADCPs * Major nutrients (silicate, phosphate, nitrate, nitrite) * Transient tracers (Chlorofluorocarbons (CFC-11 and 12), Sulphur Hexafluoride (SF_6) and Nitrous Oxide (N_2O)) * Carbon components: total dissolved inorganic carbon (DIC), total alkalinity, pH, and partial pressure of CO_2, dissolved organic carbon (DOC), total dissolved nitrogen (TDN) * Nitrate isotopes and radiocarbons * HPLC pigments and particulate organic carbon (POC) * Sargassum seaweed * Bathymetry and shipboard meteorological observations * UVP high-resolution digital images to study large (>100 µm) particles and zooplankton * Size-fractioned microbial respiration * \delta^18O (ratio of stable isotopes oxygen-18 and oxygen-16) and \deltaD (Deuterium) for studying the hydrological cycle In addition to the above measurements, during the A22 8 Argo (Core), 4 Go-BGC and 2 RAFOS floats, and 19 solar-powered spotter buoys (measuring wave, wind, and sea surface temperature) were deployed. Programs and Principal Investigators ------------------------------------ +---------------------------+---------------------------+---------------------------+---------------------------+ | Program | Affiliation | Principal Investigator | Email | |===========================|===========================|===========================|===========================| | *CTDO* Data, Salinity, | *UCSD*, *SIO* | Susan Becker, Jim Swift | sbecker@ucsd.edu, | | Nutrients, Dissolved O_2 | | | jswift@ucsd.edu | +---------------------------+---------------------------+---------------------------+---------------------------+ | Total CO_2 (DIC) | *AOML*, *PMEL*, *NOAA* | Richard Feely, Rik | richard.a.feely@noaa.gov, | | | | Wanninkhof | Rik.Wanninkhof@noaa.gov | +---------------------------+---------------------------+---------------------------+---------------------------+ | Underway Temperature, | *PMEL*, *NOAA* | Simone Alin | simone.r.alin@noaa.gov | | Salinity, and pCO_2 | | | | +---------------------------+---------------------------+---------------------------+---------------------------+ | Total Alkalinity, pH | *SIO*, *RSMAS* | Andrew Dickson, Frank | adickson@ucsd.edu, | | | | Millero | fmillero@rsmas.miami.edu | +---------------------------+---------------------------+---------------------------+---------------------------+ | Discrete pCO_2 | *PMEL*, *NOAA* | Rik Wanninkhof | Rik.Wanninkhof@noaa.gov | +---------------------------+---------------------------+---------------------------+---------------------------+ | SADCP | *UH* | Eric Firing | efiring@soest.hawaii.edu | +---------------------------+---------------------------+---------------------------+---------------------------+ | *LADCP* | *LDEO* | Andreas Thurnherr | ant@ldeo.columbia.edu | +---------------------------+---------------------------+---------------------------+---------------------------+ | *CFCs*, *SF6*, *N2O* | *UW* | Mark Warner | warner@u.washington.edu | +---------------------------+---------------------------+---------------------------+---------------------------+ | *DOC*, *TDN* | *UCSB* | Craig Carlson | craig_carlson@ucsb.edu | +---------------------------+---------------------------+---------------------------+---------------------------+ | C13 & C14 | *UW*, *WHOI* | Rolf Sonnerup, Roberta | rolf@uw.edu, | | | | Hansman | rhansman@whoi.edu | +---------------------------+---------------------------+---------------------------+---------------------------+ | Transmissometry | *TAMU* | Wilf Gardner | wgardner@ocean.tamu.edu | +---------------------------+---------------------------+---------------------------+---------------------------+ | Chipod | *OSU* | Jonathan Nash | nash@coas.oregonstate.edu | +---------------------------+---------------------------+---------------------------+---------------------------+ | Argo Floats | *WHOI* | Susan Wijffels, Steven | swijffels@whoi.edu, | | | | Jayne, Pelle Robbins | sjayne@whoi.edu, | | | | | probbins@whoi.edu. | +---------------------------+---------------------------+---------------------------+---------------------------+ | BGC Floats | *MBARI*, *UW*, | Kenneth Johnson, Steven | johnson@mbari.org, | | | *Princeton*, *SIO*, | Riser, Jorge Sarmiento, | riser@uw.edu, | | | *WHOI* | Lynne Talley, Susan | jls@princeton.edu, | | | | Wijffels | ltalley@ucsd.edu, | | | | | swijffels@whoi.edu | +---------------------------+---------------------------+---------------------------+---------------------------+ | RAFOS Floats | *WHOI* | Viviane Menezes | vmenezes@whoi.edu | +---------------------------+---------------------------+---------------------------+---------------------------+ | Canadian Arvor Floats | *DFO-MPO* | Clark Richards | Clark.Richards@dfo- | | | | | mpo.gc.ca | +---------------------------+---------------------------+---------------------------+---------------------------+ | Nitrate isotopes | *Princeton* | Daniel Sigman | sigman@princeton.edu | +---------------------------+---------------------------+---------------------------+---------------------------+ | Oxygen isotopes | *UArizona* | Kaustubh Thirumalai | kaustubh@email.arizona.e | | | | | du | +---------------------------+---------------------------+---------------------------+---------------------------+ | *UVP* | *UAF* | Andrew McDonnell | amcdonnell@alaska.edu | +---------------------------+---------------------------+---------------------------+---------------------------+ | Spotter drifters | Sofar Ocean | Cameron Dunning | cameron@sofarocean.com | +---------------------------+---------------------------+---------------------------+---------------------------+ | Sargassum | *WHOI* | Dennis McGillicuddy | dmcgillicuddy@whoi.edu | +---------------------------+---------------------------+---------------------------+---------------------------+ Science Team and Responsibilities --------------------------------- +---------------------------+---------------------------+---------------------------+---------------------------+ | Duty | Name | Affiliation | Email Address | |===========================|===========================|===========================|===========================| | Chief Scientist | Viviane Menezes | *WHOI* | vmenezes@whoi.edu | +---------------------------+---------------------------+---------------------------+---------------------------+ | Co-Chief Scientist | Jesse Anderson | *WHOI* | jessea785@gmail.com | +---------------------------+---------------------------+---------------------------+---------------------------+ | CTD Watchstander | Holly Olivarez | *CU Boulder* | holly.olivarez@colorado. | | | | | edu | +---------------------------+---------------------------+---------------------------+---------------------------+ | CTD Watchstander | Maya Prabhakar | *UArizona* | mayaprabhakar@email.ariz | | | | | ona.edu | +---------------------------+---------------------------+---------------------------+---------------------------+ | CTD Watchstander | Victoria Schoenwald | *U Miami* | vks16@rsmas.miami.edu | +---------------------------+---------------------------+---------------------------+---------------------------+ | LADCP, CTD Watchstander | Ali Siddiqui | *JHU* | asiddi24@jhu.edu | +---------------------------+---------------------------+---------------------------+---------------------------+ | Nutrients, *ODF* | Susan Becker | *UCSD* *ODF* | sbecker@ucsd.edu | | supervisor, *SOCCOM* | | | | | floats | | | | +---------------------------+---------------------------+---------------------------+---------------------------+ | Nutrients | Alexandra Fine | *NOAA* | alexandra.fine@noaa.gov | +---------------------------+---------------------------+---------------------------+---------------------------+ | CTDO Processing | Michael Kovatch | *UCSD* *ODF* | mkovatch@ucsd.edu | +---------------------------+---------------------------+---------------------------+---------------------------+ | Salts, ET, CTD/Rosette | John Calderwood | *UCSD* *SEG* | jcalderwood@ucsd.edu | | Maintenance | | | | +---------------------------+---------------------------+---------------------------+---------------------------+ | Salts, CTD/Rosette | Caitlyn Webster | *UCSD* *STS* | cwebster@ucsd.edu | | Maintenance | | | | +---------------------------+---------------------------+---------------------------+---------------------------+ | Dissolved O_2, Database | Andrew Barna | *UCSD* *ODF* | abarna@ucsd.edu | | Management | | | | +---------------------------+---------------------------+---------------------------+---------------------------+ | Dissolved O_2 | Robert Freiberger | *UCSD* | rfreiberger@ucsd.edu | +---------------------------+---------------------------+---------------------------+---------------------------+ | *UVP* | Stephane O’Daly | *UAF* | shodaly2@alaska.edu | +---------------------------+---------------------------+---------------------------+---------------------------+ | *DIC*, underway pCO2 | Andrew Collins | *UW* | andrew.collins@noaa.gov | +---------------------------+---------------------------+---------------------------+---------------------------+ | pCO2 | Patrick Mears | *U Miami* | patrick.mears@noaa.gov | +---------------------------+---------------------------+---------------------------+---------------------------+ | *DIC* | Charles Featherstone | *NOAA* | charles.featherstone@noa | | | | | a.gov | +---------------------------+---------------------------+---------------------------+---------------------------+ | *CFCs*, SF6 | Mark Warner | *UW* | warner@u.washington.edu | +---------------------------+---------------------------+---------------------------+---------------------------+ | *CFCs*, SF6 | Bonnie Chang | *UW* | bxc@uw.edu | +---------------------------+---------------------------+---------------------------+---------------------------+ | *CFCs*, SF6 student | Lillian Henderson | *U Miami* | lch39@miami.edu | +---------------------------+---------------------------+---------------------------+---------------------------+ | pH, Total Alkalinity | Sidney Wayne | *HPU* | sidneyelisawayne@gmail.c | | | | | om | +---------------------------+---------------------------+---------------------------+---------------------------+ | pH, Total Alkalinity | Daniela Nestory | *UCSD* | dnestory@ucsd.edu | +---------------------------+---------------------------+---------------------------+---------------------------+ | pH, Total Alkalinity | Carmen Rodriguez | *U Miami* | crodriguez@rsmas.miami.e | | | | | du | +---------------------------+---------------------------+---------------------------+---------------------------+ | pH, Total Alkalinity | Albert Ortiz | *U Miami* | albert.ortiz@rsmas.miami | | | | | .edu | +---------------------------+---------------------------+---------------------------+---------------------------+ | *DOC*, *TDN* | Chance English | *UCSB* | cje@ucsb.edu | +---------------------------+---------------------------+---------------------------+---------------------------+ | Marine Technician | Stephen Jalickee | *UW* | jalickee@uw.edu | +---------------------------+---------------------------+---------------------------+---------------------------+ | Marine Technician | Elizabeth Ricci | *UW* | ericci@uw.edu | +---------------------------+---------------------------+---------------------------+---------------------------+ Cruise Narrative ================ [image]GO-SHIP A22 2021 occupation. Black dots are used for CTD/LADCP/rosette stations in the Caribbean Sea, red in the Anegada Passage, blue along 66W and pink following the Line-W. PR stands for Puerto Rico. The A22 2021 occupation (Figure 1) followed the 2012 transect, except that nine stations were added in the region between the south of Puerto Rico and Bermuda. These additional stations made the nominal spacing for the 2021 occupation about 30 nm (50 km) in the open ocean. Like 2012, stations were more spaced (more than 40- nm) in two areas: around Puerto Rico and Bermuda because the sea is very shallow there (< 50 m). The initial cruise length (28-days) was planned so that there were two weather days if a weather system put CTD operations on hold. Previous occupations of this transect were impacted by weather systems. In 2012, a similar period (April-May) as 2021, a weather system delayed operation at the beginning of the cruise. As explained below, the weather was not a problem in 2021; all 90 planned stations were successfully occupied, with the full suite of core GO-SHIP chemical and physical parameters measured from the sea surface to 10 m above the seafloor (as described in the following sections). The A22 2021 cruise had a total duration of 27 days. In contrast to 2012, the A22 started at its most equatorial position (12.6N-70W) and ran northward. We departed from St. Thomas (18.3N-64.9W), US Virgin Island, on April 20 and arrived in Woods Hole (41.5N-70.7W), Massachusetts, on May 16, a day earlier than initially predicted due to excellent weather and a faster transit speed than anticipated (sustained 13 knots). The A22 was occupied immediately after the A20 (~52W), which started in Woods Hole, Massachusetts, and worked towards St. Thomas. Because of the COVID-19 pandemics, we had fewer participants during the A20/A22 journey, each leg with a science party of twenty-five members. The smaller science party decreased our ability to take level-3 measurements in these legs compared with previous (pre-COVID) GO-SHIP cruises. More than half (14 members) participated on both cruises totalizing more than 2-months at sea. As part of the COVID-19 protocol, all members had to self-isolate in a facility for two weeks, take several COVID tests, measure body temperature twice a day (recording them online), and wear face masks. Twelve people observed isolation in St. Thomas, including the chief and co-chief scientists for the A22. One of the members broke the COVID protocol by walking outside the isolation property without a mask and could not come on board. In total, each member isolating at St. Thomas took 4 to 5 tests: before traveling to St. Thomas (1-2), at St. Thomas (2), and before board the ship (1). All 11 members were negative for COVID-19 and allowed to board R/V Thompson. During the first two weeks of the cruise, all participants wore masks outside their staterooms, kept social distance (only two people per table were allowed during meal times), and continued to monitor their body temperature through the cruise. With this strict protocol being followed by all, no COVID case was registered in both A20 and A22. The R/V Thompson departed from St. Thomas, US Virgin Island on April 20, 08:00 AST. The transit to the first station near South America was short (about 1.75 days). While in transit, early on April 21, the first Core Argo float (~15.27N-69.06W) was deployed. A test station was done in international waters (4700 m deep) to train the CTD watch- standers and incoming lab technicians. For the test station, noon time was chosen so both watches could participate it. The first cast had to be aborted as a cap was not removed. This was the only time during the A22 that a cast was aborted. The package was redeployed after bringing it back to the deck to remove the cap. Later, it was determined that the UVP did not restart on the redeployment, but the decision was made to continue with the cast. No further incident with UVP happened for the entire cruise. During the test station, the CTD watch-standers learned from the ODF technicians how to prepare the rosette, fill in the logs, make a bottom approach, and fire the bottles. It was a slow cast as everybody was learning, and mistakes were being corrected. All 36 bottles were fired, giving the CTD watch-standers as much experience as possible before beginning the first part of the A22 line where stations were close together (< 10 nm in the Caribbean Current). We arrived at the first station in the early hours of April 22. Throughout the next 24-hours, 7 stations were occupied in the Caribbean Current. The next day, we slowed the pace between stations (even waiting on), from 2h to 2.5h, to give more time for equipment charging (LADCP and UVP) and lab analysis. This procedure was adopted throughout the cruise. In every segment with stations closer than 20 nm, the time between casts was set to 2.5 or 3h depending on whether it was a half/full carbon station. This allowed the labs to take and analyze samples as much as possible, resulting in more complete datasets. Full carbon stations mean that carbon parameters samples are taken from all Niskin bottles. On partial stations (depending on how backed-up analysis is), samples are collected from about half bottles. Bottles on partial stations were selected to capture good vertical resolution. Most skipped bottles were in deep waters where DIC change is much smaller than in upper layers. At the 2021 A22 occupation, even stations were full carbon, and odds partial. Time for lab analysis is an important parameter that should be considered in future GO-SHIP cruise planning. One thing that worked well was always keeping the labs informed about the time of arrival at stations for the next two/three days ahead. This helped the techs to plan the sampling better, as many of them have expressed. For estimating the time of arrival at stations, we used the Matlab routines from Alison Macdonald (WHOI), who kindly shared with us. We adapted the routines to the A22 specificities– everything worked well and avoid sample analysis falling behind schedule. The weather was good, and the sea was flat most of the time during the 2021 occupation, except by a single day (May 10, 2021). Typically, winds were around 10 to 15 m/s along the A22 (Figure 2). The only time the winds peaked above 35 m/s was on May 10, when CTD operation was put on hold for almost a day during station #73. This was the single weather day for all cruise. Thanks to the weather forecast, we knew well in advance that the ship would face strong winds and high waves. [image]Real-time winds during the GO-SHIP A22 2021 occupation. Left is a typical day with wind strength varying from 10-20 m/s. Right is the winds for May 10 when the CTD operations were put on hold. The good weather and flat sea made CTD deployments straightforward during the 2021 occupation (Figure 3). Only minor issues happened as documented later in this report: few unfired bottles, a broken O-ring, a missed target depth, wrong numbers in the sample log, and LADCP cable connections. These issues were sporadic and immediately fixed. Besides these minor issues, two mild injuries happened during rosette preparation, which led us to double our attention as a precaution. The injuries were a slight concern through the cruise, although everybody was well. [image]Flat sea and fair winds during GO-SHIP A22 2021 occupation. Left on May 3 and Right on May 15. All 16 floats and 19 spotter buoys were deployed after stations with a ship speed of a few knots. All of them were successfully deployed by the CTD watchstanders and R/V Thompson marine technicians, as later described. For the Go-BGC floats, the deployments were chosen to match full carbon stations. This decision was taken to avoid disrupting the vertical sampling scheme of carbon parameters and at the same time to have enough depths between the surface and 2000 m to compare with these floats. Sargassum samples, a piggy-back project during the A22 2021, were also collected when stations were in the US EEZ (exclusive economic zone) or international waters. This work was conducted by the ABs coordinated by the chief-mate. Principal Finding and Features ------------------------------ The A22 transect occupied the western North Atlantic, extending from South America to the continental shelf of the Cape Cod. Along the way, it crossed main water masses of the North Atlantic (Figure 4): a strong signal of Antarctic Intermediate Water (AAIW) at the Caribbean Sea, a vestige of Antarctic Bottom Water (AABW) north of Puerto Rico (\gamma = 28.162 kg/m^3), the salty Subtropical Underwater (STUW) from the Caribbean Sea to 23-25ºN, several types of North Atlantic Deep Water (NADW) north of 30ºN and mixed waters of the Slope Sea, north of the Gulf Stream. [image]Temperature-Salinity diagram for the A22 2021 occupation. Color shows the latitude and contours potential density anomaly (kg/m^3). Map displays the A22 transect in the western North Atlantic. Water mass classification based on neutral density (\gamma) as defined by Joyce et al. (2001) In the Caribbean Sea, the water mass distribution was similar to the previous occupations. No significant change in properties in the deep ocean was observed compared to 2012 (Figure 5). But, there was slight warming and salinification over the entire basin at those depths. Between 100-300 m, the saline STUW (with salinity > 37) was easily spotted in all stations in the Caribbean (Figure 6). The STUW continued to be spotted north of Puerto Rico until 25ºN (Figure 6, upper panel). The fingerprint of AAIW (low salinity and low oxygen in the North Atlantic) was also present between 600-1000 m in the Caribbean (Figure 6). The AAIW enters the Caribbean basin through the Anegada Passage. Two stations were realized there during 2021, instead of one as in 2012. In both stations, there was a clear AAIW signal. As in 2012, the AAIW signature was intensified near South America, and its signature faded outside the Caribbean. Like 2012, the water column was well mixed and weakly stratified in the Caribbean Sea below 2000 m (Figure 6). No strong density front or mesoscale eddies could be identified in the density field at the upper layer. Between 1500-2500, slightly slanted isopycnals were noticeable near Puerto Rico (Figure 6, lower left panel), probably associated with the Caribbean deep cyclonic gyre described by [Joyce2001] based on the 1997 A22 occupation. The thermohaline front associated with the Gulf Stream was apparent at the end of the section (Figure 6). The Gulf Stream was particularly strong, with speeds measured by the shipboard ADCP of about 2.2 m/s in its core. Concurrent altimetry measurements (Figure 7) slightly underestimated it, with a maximum speed of 1.7 m/s. Compared with 2012, cooling in the deep ocean was observed north of Puerto Rico, where the DWBC passes (Figure 5). This was accompanied by a slight freshening. Below 4500, where a vestige of AABW was detected, the cooling seems to be intensified. As a result, there was an uplift of \gamma = 28.15 by about 200 m in the water column. CFCs measurements (not shown) also suggest changes north of Puerto Rico. In 2012, it was found an eddy with unusual water properties, near 21.5°N, just north of the Puerto Rico Trench. The property anomalies - high oxygen and CFCs, low salinity, and nutrients – were particularly strong between 1000-1500 meters depth. It was suggested that this eddy originated to the east of Newfoundland. In 2021, the eddy was not present. [image]Difference in potential temperature (left) and salinity (right) between 2021 and 2012 A22 occupations. Contours are neutral density in 2021 (black) and 2012 (blue). [image]Potential temperature (upper left) and salinity (upper right) distributions at A22 2021 (stations 1-90) from CTD data. Same for neutral density (lower left) and dissolved oxygen (lower right). Contours are \gamma = 26, 27, 27.6, 27.9, 28.1, and 28.15 kg/m^3. [image]Geostrophic velocities for May 11 from satellite altimeters and A22 stations (dots). [Joyce2001] Joyce, T. M., Hernandez‐Guerra, A., and Smethie, W. M. (2001), Zonal circulation in the NW Atlantic and Caribbean from a meridional World Ocean Circulation Experiment hydrographic section at 66°W, J. Geophys. Res., 106( C10), 22095– 22113, doi:10.1029/2000JC000268. CTD and Rosette Setup ===================== For A22-2021 the new STS 36 place yellow rosette and bottles, built in 2017, were used. The rosette and bottles were built before P06 2017, making this the seventh time this package has been deployed. The bottles were made with new PVC, with new non-baked o-rings and electro-polished steel springs. This represents a change from the past, where on GO-SHIP cruises using ODF equipment before P06 2017 o-rings were baked for 3 days at 100°C at 1-3 Torr in a sweeper gas of hydrogen. Springs used to be painted and Tygon tubing added to the ends to prevent paint wearing away from bottle firing. As on P06 2017 no sample contamination has been noticed by the change in o-rings and springs. The package used on A22-2021 weighs roughly 1500 lbs in air without water, and 2350 lbs in air with water. The package used on A22-2021 weighs roughly 950 lbs in water. In addition to the standard CTDO package on GO-SHIP cruises three chipods, two LADCPs, and one experimental CTD were mounted on the rosette. During the cruise we encountered a handful of problems, most notably noisy altimeter data and bottle firing issues. We describe all of the above in more detail in the sections below. Underwater Sampling Package --------------------------- CTDO/rosette/LADCP/UVP/chipod casts were performed with a package consisting of a 36 bottle rosette frame, a 36-place carousel and 36 Bullister style Niskin bottles with an absolute volume of 10.6L. Underwater electronic components primarily consisted of a SeaBird Electronics housing unit with Paroscientific pressure sensor with dual plumbed lines where each line has a pump, temperature sensor, conductivity sensor, and exhaust line. A SeaBird Electronics membrane oxygen sensor was mounted on the “primary” line. A reference thermometer, Rinko oxygen optode, transmissometer, chlorophyll-a fluorometer, and altimeter were also mounted on the rosette. Chipod, LADCP, and UVP instruments were deployed with the CTD/rosette package and their use is outlined in sections of this document specific to their titled analysis. CTD and cage were horizontally mounted at the bottom of the rosette frame, located below the carousel for all stations. The temperature, conductivity, dissolved oxygen, respective pumps and exhaust tubing was mounted to the CTD and cage housing as recommended by SBE. The reference temperature sensor was mounted between the primary and secondary temperature sensors at the same level as the intake tubes for the exhaust lines. The transmissometer was mounted horizontally on the lower LADCP brace with hose clamps around both of its ends, avoiding shiny metal or black tape inside that would introduce noise in the signal. The oxygen optode, fluorometer, and altimeter were mounted vertically inside the bottom ring of the rosette frames, with nothing obstructing their line of sight. One 300 KHz bi-directional Broadband LADCP (RDI) unit was mounted vertically on the bottom side of the frame. Another 300 KHz bi-directional Broadband LADCP (RDI) unit was mounted vertically on the top side of the frame. The LADCP battery pack was also mounted on the bottom of the frame. The LADCP and LADCP battery pack were mounted next to each other at the beginning of the cruise. If we imagine the LADCP battery being north on the rosette, the LADCP was mounted east, the CTD mounted south, and the UVP mounted west. +------------------+------------------+------------------+------------------+------------------+------------------+ | Equipment | Model | S/N | Cal Date | Stations | Group | |==================|==================|==================|==================|==================|==================| | Rosette | 36-place | Yellow | – | 901-90 | *STS*/*ODF* | +------------------+------------------+------------------+------------------+------------------+------------------+ | CTD | SBE9+ | 0914 | – | 901-90 | *STS*/*ODF* | +------------------+------------------+------------------+------------------+------------------+------------------+ | Pressure Sensor | Digiquartz | 110547 | Feb 5, 2021 | 901-90 | *STS*/*ODF* | +------------------+------------------+------------------+------------------+------------------+------------------+ | Primary | SBE3+ | 32309 | Feb 2, 2021 | 901-90 | *STS*/*ODF* | | Temperature | | | | | | +------------------+------------------+------------------+------------------+------------------+------------------+ | Primary | SBE4C | 43399 | Nov 25, 2020 | 901-90 | *STS*/*ODF* | | Conductivity | | | | | | +------------------+------------------+------------------+------------------+------------------+------------------+ | Primary Pump | SBE5 | 51871 | – | 901-90 | *UCSD* | +------------------+------------------+------------------+------------------+------------------+------------------+ | Secondary | SBE3+ | 32380 | Feb 2, 2021 | 901-90 | *STS*/*ODF* | | Temperature | | | | | | +------------------+------------------+------------------+------------------+------------------+------------------+ | Secondary | SBE4C | 41880 | Dec 4, 2020 | 901-90 | *STS*/*ODF* | | Conductivity | | | | | | +------------------+------------------+------------------+------------------+------------------+------------------+ | Secondary Pump | SBE5 | 58690 | – | 901-90 | *UCSD* | +------------------+------------------+------------------+------------------+------------------+------------------+ | Transmissometer | Cstar | 1803DR | Aug 9, 2019 | 901-90 | *TAMU* | +------------------+------------------+------------------+------------------+------------------+------------------+ | Fluorometer | WetLabs ECO-FL- | 1156 | – | 901-90 | *STS*/*ODF* | | Chlorophyll | RTD | | | | | +------------------+------------------+------------------+------------------+------------------+------------------+ | Dissolved Oxygen | SBE43 | 430255 | Nov 13, 2020 | 901-90 | *ODF* | +------------------+------------------+------------------+------------------+------------------+------------------+ | Oxygen Optode | JFE Advantech | 0296 | Apr 7, 2017 | 901-90 | *ODF* | | | Rinko-III | | | | | +------------------+------------------+------------------+------------------+------------------+------------------+ | Reference | SBE35 | 0105 | Feb 9, 2021 | 901-90 | *STS*/*ODF* | | Temperature | | | | | | +------------------+------------------+------------------+------------------+------------------+------------------+ | Carousel | SBE32 | 0187 | – | 901-43 | *STS*/*ODF* | +------------------+------------------+------------------+------------------+------------------+------------------+ | Carousel | SBE32 | 1178 | – | 44-90 | *STS*/*ODF* | +------------------+------------------+------------------+------------------+------------------+------------------+ | Altimeter | Valeport 500 | 53821 | – | 901-59, 61-90 | *UCSD* | +------------------+------------------+------------------+------------------+------------------+------------------+ | Altimeter | Valeport 500 | 48049 | – | 60 | *UCSD* | +------------------+------------------+------------------+------------------+------------------+------------------+ | DL *LADCP* | Teledyne RDI | 24497 | – | 901-90 | *LDEO* | | | WH300 | | | | | +------------------+------------------+------------------+------------------+------------------+------------------+ | UL *LADCP* | Teledyne RDI | 12734 | – | 901-90 | *LDEO* | | | WH300 | | | | | +------------------+------------------+------------------+------------------+------------------+------------------+ | UVP | – | 207 | – | 901-90 | *UAF* | +------------------+------------------+------------------+------------------+------------------+------------------+ | D2 CTD | D2 CTD | 01-1563 | – | 901-45 | *WHOI* | +------------------+------------------+------------------+------------------+------------------+------------------+ | D2 CTD | D2 CTD | 01-1565 | – | 46-90 | *WHOI* | +------------------+------------------+------------------+------------------+------------------+------------------+ | Chipods | Chipod | 2008 Ti44-5 | – | 901-90 | *OSU* | +------------------+------------------+------------------+------------------+------------------+------------------+ | Chipods | Chipod | 2027 TI44-3 | – | 901-90 | *OSU* | +------------------+------------------+------------------+------------------+------------------+------------------+ | Chipods | Chipod | 2030 Ti44-11 | – | 901-90 | *OSU* | +------------------+------------------+------------------+------------------+------------------+------------------+ [image]Package sensor setup from south. [image]Package sensor setup from east. [image]Package sensor setup from north. [image]From left to right: oxygen optode, fluorometer, LADCP battery pack, altimeter. [image]Package setup from southwest, with CTD in foreground and downlooking chipod to the right. [image]Packaget setup from west. [image]Package setup from west, top view. Winch and Deployment -------------------- The aft DESH-5 winch deployment system was used for all stations. The rosette system was suspended from a UNOLS-standard three-conductor 0.322” electro-mechanical sea cable. The sea cable was already terminated from the previous leg (A20) and no electrical or mechanical issues occurred on A22. The deck watch prepared the rosette 10-30 minutes prior to each cast. The bottles were cocked and all valves, vents, and lanyards were checked for proper orientation. Any biofouling noted was cleaned off the outside of the rosette before the next cast, and the inside of the bottles were checked for biofouling and sprayed down. LADCP technician would check for LADCP battery charge, prepare instrument for data acquisition, and disconnect cables. Once stopped on station, the Marine Technician would check the sea state prior to cast and decide if conditions were acceptable for deployment. The rosette was moved from the sampling bay out to the deck using the Thompson’s new winch- driven cart. Once on deck, the ratchet straps connecting the rosette to the cart were removed and sea cable slack was pulled up by the winch operator. CTD watch standers would then turn on the deckbox and begin data acquistion, and the cast would begin. Recovering the package at the end of the deployment was the reverse of launching. Once rolled back into the sampling bay, the ship crew secured the cart to the deck using additional ratchet straps. The carousel was rinsed and sensors were cleaned (as described below) after every cast, and then samplers were allowed to begin collecting water. Maintenance and Calibrations ---------------------------- During A22-2021 routine maintenance was done to the rosette to ensure quality of the science done. Actions taken included rinsing all electrical instruments on the rosette down with fresh water after each cast and adjusting hose clamps and guide rings as needed such that lanyards had appropriate tension. Care was taken not to rinse the spigots and other parts of the bottle that might be touched by samplers in order to not contaminate the samples. After each cast, syringes of fresh water were connected to the plumbed lines to rinse the sensors and allow them to soak between casts. While in freezing conditions, water was drained after rinse to avoid freezing in the plumbing. Overhead heaters recently installed on the Thompson were run while in freezing or near-freezing conditions. The rosette was routinely examined for valve and o-ring leaks, which were maintained as needed. SBE35RT temperature data was routinely downloaded each day. Every 20 stations, the transmissometer windows were cleaned and on deck blocked and un-blocked voltage readings were recorded prior to the cast. The transmissometer was also calibrated before the start and after the end of science operations. Logs ---- In port: Preparation of the CTD and rosette was minimal as it had nearly the same setup as A20 2021, which had just been completed. UVP arrived in St. Thomas and was mounted opposite the ADCP. Downlooking chipod mounting pole was swapped out to allow the sensor to be closer to the leading edge of the rosette. Additional integrity checks on the rosette, such as checking lanyard angles, o-ring and lanyard replacement, and spigot movement waited until being underway to be checked as lower priority tasks. We are using a new mounting system for the downward looking LADCP which has the LADCP clamped facing inward instead of outward, which will cause problems if we need to change that LADCP in rough weather. April 21, 2021 90001 – First test cast aborted around 350 m. Tube connecting the primary and secondary pumps (attached in port to prevent fouling of the plumbing lines) was not removed prior to start of cast, identified initially in data by large differences in primary/secondary T/C lines. 90002 – Test cast to 4500 m. UVP did not turn on during ascent from initial 20 m soak. Tried soaking again (at 20 m), still did not activate. Upon recovery, data from cast 90001 was present but nothing was recoreded from 90002. The assumption is that the rosette was not on deck long enough to fully power cycle the UVP. April 22, 2021 00101 – UVP turned on as expected; no issues noted. Adjusted guide ring on bottle 30. 00201 – Bottles 4, 5, 6, and 9 were leaking, 11 and 12 had loose vents. 00301 – Fired surface bottle (#23) on the fly due to large swell. Rosette sat at 35 m for longer than standard while deck crew prepared for recovery. 00401 – Adjusted guide ring on bottles 29, 30, 32 before cast. 00501 – No issues noted. 00601 – No issues noted. April 23, 2021 00701 – Bottle 25 did not close, top cap was stuck against rosette frame crossbar. Entire bottle was moved downward to prevent that from happening again. 00801 – No issues noted. 00901 – No issues noted. 01001 – ADCP data reported in multiple files, suspected power issues. Swapped out cable and battery. April 24, 2021 01101 – No issues noted. 01201 – Bottle 3 did not fire. 01301 – No issues noted. 01401 – Surface bottle (#36) was too cold, closer to temperature of 400-500 m bottles. Inspecting after cast, the bottom end cap was loose enough to close itself, likely early closure. Adjusted guide ring to prevent early closures. April 25, 2021 01501 – No issues noted. 01601 – Adjusted guide ring for bottle 32 before cast. Miscommunication with winch during bottom approach: stopped early (~20 m from bottom), fired bottle as normal, after which winch continued downward briefly. On way up, bottle 2 was misfired shortly after leaving the bottom. 01701 – No issues noted. 01801 – No issues noted. April 26, 2021 No issues noted for stations 01901-02101. April 27, 2021 02201 – No issues noted. 02301 – No issues noted. 02401 – ~160 m salnity spike (just primary line?) 02501 – No issues noted. 02601 – No issues noted. 02701 – Taking less than half a rosette worth of bottles, fired odd bottles to make recovery easier (uniformly distributed weight instead of all to one side). Was confusing for analysts in other groups, will not do again. 02801 – 115 m depth bottle mistakenly skipped, shifted remaining bottles appropriately. April 28, 2021 02901 – No issues noted. 03001 – Adjusted guide rings on 2, 10, 12, 14, 19, 32-36 before cast. 03201 – Raised bottle 26 up before cast, may have been firing late because of poor placement. 03301 – Bottle 3 did not close. April 29, 2021 03401 – Bottle 22 did not close. Adjusted bottle 23 height since it was getting stuck on crossbar. 03501 – Bottle 3 did not close. Replaced carouse latch for bottle 33 and raised bottle 22 to improve lanyard angle. 03601 – Adjusted guide ring son bottle 2, 8, 9, 17, 19, 21, 24. 03701 – Air vent on bottle 35 was not fully shut. April 30, 2021 03801 – Salinity signal was a little spiky during soak but quickly remedied itself (may just be bottom of mixed layer or something pulled through lines?). 03901 – Bottle 26 guide ring adjusted upward. 04001 – No issues noted. May 1, 2021 04101 – Bottle 3 did not fire, bottle 16 was leaking due to loose air vent. Bottle 26 accidentally misfired on fly. 04201 – Bottle 3 did not fire. 04301 – Adjusted guide rings on bottles 17-21, 23, 32. Skipped firing bottle 3, will repair “spare” (i.e. primary) carousel during cast and replcae during transit to next. May 2, 2021 04401 – Adjusted guide ring on bottle 15. Replaced carousel with primary, after swapping solenoid #12. 04501 – No issues noted. 04601 – D2 1563 replaced with 1565 at PI’s request. Adjusted guide rings on bottles 11, 15, 19, 21, 23, 29, 30, 33, and 35. UVP did not show much change in surface during soak but was fine during cast; suspected the upper water column did not have much to photograph. 04701 – Downlooking chipod was remounted with thicker rubber between unistruct and frame, hoping to stop the shifting which is occurring during deployment, cast, or recovery. May 3, 2021 04801 – Spigot on bottle 35 was not fully closed. 04901 – Altimeter spiking during bottom approach. 05001 – Replaced spigot o-rings for bottle 16 before cast, was sticky and hard to fully close. Altimeter continuing to be spiky during bottom approach. May 4, 2021 05101 – Bottle 35 was leaking, broken air vent o-ring – replaced before next cast. Also replaced for bottles 5, 7, and 9. 05201 – Altimeter continuing to be spiky during bottom approach. 05301 – Adjusted guide rings on 18, 29-34 before cast. Altimeter did not kick in until ~50 m from bottom, then was noisy during the entire bottom approach; stopped ~20 m from bottom to be conservative. Bucket testing afterward did not reveal any obvious problems and comparison with a new (presumably function) altimeter had the same results. 05401 – Adjusted guide rings on 8, 10, 36. Same altimeter behavior. May 5, 2021 05501 – Same altimeter behavior. Will leave as is since the behavior is now predictable, rather than introduce new unknowns. Bottle 25 fired quickly after stop, rather than waiting 30 seconds. Spigot pull tab on bottle 6 broken on recovery. 05601 – Same altimeter behavior. 05701 – Replaced o-rings and broken pull tab on bottle 6 before cast. May 6, 2021 05801 – Spiky transmissometer data, tape on hose clamp came loose. After cast, wrapped electrical tape in a spiral around hose clamp to prevent it from peeling up. 05901 – Altimeter seems to be getting worse, swapping in TGT’s 48049 before cast 60. 06001 – Adjusted guide rings on 10, 18, 20, 24, 29-33, 35, 36. Altimeter not much different. Swapping back to original (S/N 53821) and also swapping to TGT’s cable to see if that is the issue. 06101 – Altimeter behavior largely the same. Ultimately decided noise is due to rosette angle and bathymetry scattering the pings, the effect of which is reduced closer to the bottom. May 7, 2021 06201 – Transmissometer spike ~1130 m. 06301 – Adjusted guide rings on the usual bottles. After cinching down with drill, tightened every hose clamp further with a screwdriver. Was able to get at least 1/4 turn out of each, drill not as powerful as it used to be? 06401 – No issues noted. May 8, 2021 06501 – Raining heavily during deployment. 06601 – No issues noted. 06701 – No issues noted. May 9, 2021 06801 – No issues noted. 06901 – Rubber between top bottle standoff sliding out, removed after cast. Hose clamp was not tightened down so bottle was a little loose. 07001 – At 5 m bottle stop, there was a miscommuncation and the ship rotated to face into the swell. Rotated before bottle fired so sample is highly contaminated. 07101 – Tighted all guide ring hose clamps with screwdriver once again. May 10, 2021 07201 – No issues noted. Weather delay for the rest of the day. May 11, 2021 07301 – Changed top end cap, lanyards contected to it, and o-ring. Miscommunication between shifts led to the interior lanyard (cap to spring) to be changed again. 07401 – No issues noted. 07501 - Bottle 29 vent was not fully closed. May 12, 2021 07601 – Bottle 2 did not seal all the way, o-ring not well seated – o-ring replaced by night shift (miscommuncation again, o-ring was just recently changed). Inter-lanyards (cap to cap) replaced on bottles 28 and 29. 07701 – Bottle 2 o-ring not well seated again, may have questionable data. Tried to remove any twist in o-ring and re-seat. Gulf Stream currents very strong, large wire angle. 07801 – Inter-lanyard (cap to cap) for bottle 29 was very tight upon recovery, removed shortly after getting on deck. Old one was ~1.5” too short – replaced with a new one of appropriate length before cast 79. Bottle 2 o-ring unseated again, replaced end cap with original one that was working properly. May 13, 2021 07901 – ADCP having trouble turning on, cast slightly delayed. Rosette drifted upward during bottom bottle stop. 08001 – No issues noted. 08101 – Adjusted guide ring 23, tightened all others with screwdriver. Spigot on bottle #16 is very sticky, replaced before cast 82. 08201 – No issues noted. May 14, 2021 08301 – No issues noted. 08401 – No issues noted. 08501 – Mixed layer shallow, no good spot to switch to auto-cast. 08601 – Trying bottle stop experiment, fired triplicates at 30, 60, and 90 seconds after stop, at two depths. 08701 – No issues noted. Trying bottle stop experiment, fired triplicates at 30, 60, and 90 seconds after stop, at two depths. May 15, 2021 08801 – Trying bottle stop experiment, fired triplicates at 30, 60, and 90 seconds after stop, at two depths. 08901 – No issues noted. 09001 – No issues noted. Sensor Problems --------------- *SBE 32 Carousel*: Another solenoid failure, this time in secondary carousel. Primary was fixed and swapped in on before cast 44. Pictures of swollen solenoid shown below. [image]Bad solenoid (center), cloudy and raised edge from corrosion. [image]Bad solenoid (left), cloudy and raised edge from corrosion. *Altimeter spiking*: Ended up just being bathymetry/bad returns. Swapping altimeter and cables made no difference. *Bottle guide rings*: Guide rings continually slipped during the whole cruise. In the end, the issue was they were not being sufficiently tightened by the normal drill we used – fixed by hand tightening further with screwdriver. CTDO and Hydrographic Analysis ============================== PIs * Susan Becker (SIO) * James Swift (SIO) Technicians * Michael Kovatch (SIO) CTDO and Bottle Data Acquisition -------------------------------- The CTD data acquisition system consisted of an SBE-11+ (V2) deck unit and a networked generic PC workstation running Windows 10. SBE SeaSave7 v.7.26.7.107 software was used for data acquisition and to close bottles on the rosette. CTD deployments were initiated by the console watch operators (CWO) after the ship had stopped on station. The watch maintained a CTD cast log for each attempted cast containing a description of each deployment event and any problems encountered. Once the deck watch had deployed the rosette, the winch operator would lower it to 10 meters. The CTD sensor pumps were configured to start 10 seconds after the primary conductivity cell reports salt water in the cell. The CWO checked the CTD data for proper sensor operation, waited for sensors to stabilize, and instructed the winch operator to bring the package to the surface in good weather or no more than 5 meters in high seas. The winch was then instructed to lower the package to the initial target wire-out at no more than 30 m/min for the first 100 m and no more than 6 0m/min after 100 m depending on sea-cable tension and the sea state. The CWO monitored the progress of the deployment and quality of the CTD data through interactive graphics and operational displays. The altimeter channel, CTD pressure, wire-out and center multi-beam depth were all monitored to determine the distance of the package from the bottom. The winch was directed to slow decent rate to 30 m/min 100 m from the bottom. The bottom of the CTD cast was usually to within 10-20 meters of the bottom determined by altimeter data. For each upcast, the winch operator was directed to stop the winch at up to 36 predetermined sampling pressures. These standard depths were staggered every station using 3 sampling schemes. The CTD CWO waited 30 seconds prior to tripping sample bottles, to ensure package had shed its wake. An additional 15 seconds elapsed before moving to the next consecutive trip depth, which allowed for the SBE35RT to record bottle trip temperature averaged from 13 samples. After the last bottle was closed, the CWO directed winch to recover the rosette. Once the rosette was out of the water and on deck, the CWO terminated the data acquisition, turned off the deck unit and assisted with rosette sampling. Additionally, the watch created a sample log for the deployment which recorded the depths bottles were tripped and correspondence between rosette bottles and analytical samples drawn. Normally the CTD sensors were rinsed after each station using syringes of fresh water connected to Tygon tubing. The tubing was left on the CTD between casts, with the temperature and conductivity sensors immersed in fresh. Each bottle on the rosette had a unique serial number, independent of the bottle position on the rosette. Sampling for specific programs were outlined on sample log sheets prior to cast recovery or at the time of collection. The bottles and rosette were examined before samples were drawn. Any abnormalities were noted on the sample log, stored in the cruise database and reported in the APPENDIX. CTDO Data Processing -------------------- Shipboard CTD data processing was performed after deployment using SIO/ODF CTD processing software “ctdcal” v. 0.1. CTD acquisition data were copied onto a OS X system, and then processed. CTD data at bottle trips were extracted, and a 2-decibar downcast pressure series created. The pressure series data set was submitted for CTD data distribution after corrections outlined in the following sections were applied. A total of 90 CTD stations were occupied including one test station. A total of 91 CTDO/rosette/LADCP/UVP/chipod casts were completed. CTD data were examined at the completion of each deployment for clean corrected sensor response and any calibration shifts. As bottle salinity and oxygen results became available, they were used to refine conductivity and oxygen sensor calibrations. Temperature, salinity and, dissolved O_2 comparisons were made between down and upcasts as well as between groups of adjacent deployments. Vertical sections of measured and derived properties from sensor data were checked for consistency. A number of issues were encountered during A22-2021 that directly impacted CTD analysis. Issues that directly impacted bottle closures, such as slipping guide rings, were detailed in the Underwater Sampling Package section of this report. Temperature, conductivity, and oxygen analytical sensor issues are detailed in the following respective sections. Pressure Analysis ----------------- Laboratory calibrations of CTD pressure sensors were performed prior to the cruise. Dates of laboratory calibration are recorded on the underway sampling package table and calibration documents are provided in the APPENDIX. The lab calibration coefficients provided on the calibration report were used to convert frequencies to pressure. Initial SIO pressure lab calibration slope and offsets coefficients were applied to cast data. A shipboard calibration offset was applied to the converted pressures during each cast. These offsets were determined by the pre and post- cast on-deck pressure offsets. The pressure offsets were applied per cast. CTD #0914: +-----------------------------------+-----------------------------------+-----------------------------------+ | | Start P (dbar) | End P (dbar) | |===================================|===================================|===================================| | Min | -0.20 | -0.28 | +-----------------------------------+-----------------------------------+-----------------------------------+ | Max | 0.05 | -0.08 | +-----------------------------------+-----------------------------------+-----------------------------------+ | Average | 0.09 | -0.19 | +-----------------------------------+-----------------------------------+-----------------------------------+ On-deck pressure reading varied from -0.20 to 0.05 dbar before the casts, and -0.28 to -0.08 dbar after the casts. The pressure offset varied from -0.24 to 0.09, with a mean value of -0.1 dbar. Temperature Analysis -------------------- Laboratory calibrations of temperature sensors were performed prior to the cruise at the SIO Calibration Facility. Dates of laboratory calibration are recorded on the underway sampling package table and calibration documents are provided in the APPENDIX. The pre-cruise laboratory calibration coefficients were used to convert SBE3plus frequencies to ITS-90 temperature. Additional shipboard calibrations were performed to correct systematic sensor bias. Two independent metrics of calibration accuracy were used to determine sensor bias. At each bottle closure, the primary and secondary temperature were compared with each other and with a SBE35RT reference temperature sensor. The SBE35RT Digital Reversing Thermometer is an internally-recording temperature sensor that operates independently of the CTD. The SBE35RT was located equidistant between the two SBE3plus temperature sensors. The SBE35RT is triggered by the SBE32 carousel in response to a bottle closure. According to the manufacturer’s specifications, the typical stability is 0.001°C/year. The SBE35RT was set to internally average over 13 samples, approximately a 15 second period. A functioning SBE3plus sensor typically exhibit a consistent predictable well-modeled response. The response model is second-order with respect to pressure and second-order with respect to temperature: T_{cor} = T + cp_2 P^2 + cp_1 P + ct_2 T^2 + ct_1 T + c_0 Fit coefficients are shown in the following tables. Primary temperature (T1) coefficients. ^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^ +------------------+------------------+------------------+------------------+------------------+------------------+ | Station | cp_2 | cp_1 | ct_2 | ct_1 | c_0 | |==================|==================|==================|==================|==================|==================| | 901-29 | 9.127e-11 | -7.1661e-7 | 0.0 | 0.0 | 4.7065e-4 | +------------------+------------------+------------------+------------------+------------------+------------------+ | 30-72 | 8.4036e-11 | -8.6330e-7 | 0.0 | 0.0 | 1.1989e-3 | +------------------+------------------+------------------+------------------+------------------+------------------+ | 73-90 | -4.6532e-11 | 1.2251e-7 | 0.0 | 0.0 | -8.1808e-4 | +------------------+------------------+------------------+------------------+------------------+------------------+ Secondary temperature (T2) coefficients. ^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^ +------------------+------------------+------------------+------------------+------------------+------------------+ | Station | cp_2 | cp_1 | ct_2 | ct_1 | c_0 | |==================|==================|==================|==================|==================|==================| | 901-29 | 0.0 | -2.1424e-7 | 0.0 | 0.0 | -1.4331e-4 | +------------------+------------------+------------------+------------------+------------------+------------------+ | 30-72 | 0.0 | -8.1227e-8 | 0.0 | 0.0 | -6.3841e-4 | +------------------+------------------+------------------+------------------+------------------+------------------+ | 73-90 | 0.0 | -1.3354e-7 | 0.0 | 0.0 | -7.2422e-4 | +------------------+------------------+------------------+------------------+------------------+------------------+ Corrected temperature differences are shown in the following figures. [image]SBE35RT-T1 versus station. [image]Deep SBE35RT-T1 by station (Pressure \geq 2000dbar). [image]SBE35RT-T2 versus station. [image]Deep SBE35RT-T2 by station (Pressure \geq 2000dbar). [image]T1-T2 versus station. [image]Deep T1-T2 versus station (Pressure \geq 2000dbar). [image]SBE35RT-T1 versus pressure. [image]SBE35RT-T2 versus pressure. [image]T1-T2 versus pressure. The 95% confidence limits for the mean low-gradient (values -0.002°C \leq T1-T2 \leq 0.002°C) differences are ±0.00391°C for SBE35RT-T1, ±0.00387°C for SBE35RT-T2 and ±0.00157°C for T1-T2. The 95% confidence limits for the deep temperature residuals (where pressure \geq 2000dbar) are ±0.00087°C for SBE35RT-T1, ±0.00099°C for SBE35RT-T2 and ±0.00087°C for T1-T2. Minor complications impacted the temperature sensor data used for the A22-2021 cruise. * Near-surface temperature gradients in the southern end of the survey were extremely sharp, occasionally causing SBE35RT readings to be questionable. The resulting affected sections of data have been coded and documented in the quality code APPENDIX. Conductivity Analysis --------------------- Laboratory calibrations of conductivity sensors were performed prior to the cruise at the Sea-Bird Calibration Facility. Dates of laboratory calibration are recorded on the underway sampling package table and calibration documents are provided in the APPENDIX. The pre-cruise laboratory calibration coefficients were used to convert SBE4C frequencies to mS/cm conductivity values. Additional shipboard calibrations were performed to correct sensor bias. Corrections for both pressure and temperature sensors were finalized before analyzing conductivity differences. Two independent metrics of calibration accuracy were examined. At each bottle closure, the primary and secondary conductivity were compared with each other. Each sensor was also compared to conductivity calculated from check sample salinities using CTD pressure and temperature. The differences between primary and secondary temperature sensors were used as filtering criteria to reduce the contamination of conductivity comparisons by package wake. The coherence of this relationship is shown in the following figure. [image]Coherence of conductivity differences as a function of temperature differences. [image]Corrected C_Bottle - C1 versus station. [image]Deep Corrected C_Bottle - C1 versus station (Pressure >= 2000dbar). [image]Corrected C_Bottle - C2 versus station. [image]Deep Corrected C_Bottle - C2 versus station (Pressure >= 2000dbar). [image]Corrected C1-C2 versus station. [image]Deep Corrected C1-C2 versus station (Pressure >= 2000dbar). [image]Corrected C_Bottle - C1 versus pressure. [image]Corrected C_Bottle - C2 versus pressure. [image]Corrected C1-C2 versus pressure. A functioning SBE4C sensor typically exhibit a predictable modeled response. Offsets for each C sensor were determined using C_Bottle - C_CTD differences in a deeper pressure range (500 or more dbars). After conductivity offsets were applied to all casts, response to pressure, temperature and conductivity were examined for each conductivity sensor. The response model is second-order with respect to pressure, second-order with respect to temperature, and second- order with respect to conductivity: C_{cor} = C + cp_2 P^2 + cp_1 P + ct_2 T^2 + ct_1 T + cc_2 C^2 + cc_1 C + \text{Offset} Fit coefficients are shown in the following tables. Primary conductivity (C1) coefficients. ^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^ +--------------+--------------+--------------+--------------+--------------+--------------+--------------+--------------+ | Station | cp_2 | cp_1 | ct_2 | ct_1 | cc_2 | cc_1 | c_0 | |==============|==============|==============|==============|==============|==============|==============|==============| | 901-29 | 2.2312e-10 | -1.7838e-6 | 0.0 | -3.7387e-4 | 0.0 | 0.0 | 1.4153e-3 | +--------------+--------------+--------------+--------------+--------------+--------------+--------------+--------------+ | 30-73 | 2.9375e-10 | -2.7234e-6 | 0.0 | -5.1639e-4 | 0.0 | 0.0 | 3.1780e-3 | +--------------+--------------+--------------+--------------+--------------+--------------+--------------+--------------+ | 74-90 | 3.0952e-11 | -7.2679e-7 | 0.0 | -2.3689e-4 | 0.0 | 0.0 | -1.1248e-3 | +--------------+--------------+--------------+--------------+--------------+--------------+--------------+--------------+ Secondary conductivity (C2) coefficients. ^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^ +--------------+--------------+--------------+--------------+--------------+--------------+--------------+--------------+ | Station | cp_2 | cp_1 | ct_2 | ct_1 | cc_2 | cc_1 | c_0 | |==============|==============|==============|==============|==============|==============|==============|==============| | 901-29 | 1.6912e-10 | -1.3829e-6 | 0.0 | 0.0 | 0.0 | -3.2935e-4 | 1.3273e-2 | +--------------+--------------+--------------+--------------+--------------+--------------+--------------+--------------+ | 30-73 | 1.7407e-10 | -1.6959e-6 | 0.0 | 0.0 | 0.0 | -5.1483e-4 | 2.0042e-2 | +--------------+--------------+--------------+--------------+--------------+--------------+--------------+--------------+ | 74-90 | 5.4163e-11 | -9.0604e-7 | 0.0 | 0.0 | 0.0 | -2.0301e-4 | 8.8063e-3 | +--------------+--------------+--------------+--------------+--------------+--------------+--------------+--------------+ Salinity residuals after applying shipboard P/T/C corrections are summarized in the following figures. Only CTD and bottle salinity data with “acceptable” quality codes are included in the differences. Quality codes and comments are published in the APPENDIX of this report. [image]Salinity residuals versus station. [image]Deep Salinity residuals versus station (Pressure >= 2000dbar). [image]Salinity residuals versus pressure. The 95% confidence limits for the mean low-gradient (values -0.002 ºC \leq T1-T2 \leq 0.002 ºC) differences are ±0.00512 mPSU for salinity- C1SAL. The 95% confidence limits for the deep salinity residuals (where pressure \geq 2000dbar) are ±0.00158 mPSU for salinity-C1SAL. Minimal issues affected conductivity and calculated CTD salinities during this cruise. * Bottle stops in halocline may have had insufficient stop time during some casts, leading to low-biased measurements. The resulting affected sections of data have been coded and documented in the quality code APPENDIX. CTD Dissolved Oxygen (SBE43) ---------------------------- Laboratory calibrations of the dissolved oxygen sensors were performed prior to the cruise at the SBE calibration facility. Dates of laboratory calibration are recorded on the underway sampling package table and calibration documents are provided in the APPENDIX. The pre-cruise laboratory calibration coefficients were used to convert SBE43 frequencies to µmol/kg oxygen values for acquisition only. Additional shipboard fitting were performed to correct for the sensors non-linear response. Corrections for pressure, temperature, and conductivity sensors were finalized before analyzing dissolved oxygen data. Corrections for hysteresis are applied following Sea-Bird Application Note 64-3. The SBE43 sensor data were compared to dissolved O_2 check samples taken at bottle stops by matching the downcast CTD data to the upcast trip locations along isopycnal surfaces. CTD dissolved O_2 was then calculated using Clark Cell MPOD O_2 sensor response model for Beckman/SensorMedics and SBE43 dissolved O_2 sensors. The residual differences of bottle check value versus CTD dissolved O_2 values are minimized by optimizing the PMEL DO sensor response model coefficients using the BFGS non-linear least-squares fitting procedure. The general form of the PMEL DO sensor response model equation for Clark cells follows Brown and Morrison [Mill82] and Owens [Owen85]. Dissolved O_2 concentration is then calculated: O_2 = S_{oc} \cdot (V + V_{\textrm{off}} + \tau_{20} \cdot e^{(D_1 \cdot p + D_2 \cdot (T - 20))} \cdot dV/dt) \cdot O_{sat} \cdot e^{T_{cor} \cdot T} \cdot e^{[(E \cdot p) / (273.15 + T)]} Where: * V is oxygen voltage (V) * D_1 and D_2 are (fixed) SBE calibration coefficients * T is corrected CTD temperature (°C) * p is corrected CTD pressure (dbar) * dV/dt is the time-derivative of voltage (V/s) * O_sat is oxygen saturation * S_oc, V_off, \tau_20, T_cor, and E are fit coefficients All stations were fit together to get an initial coefficient estimate. Stations were then fit individually to refine the coefficients as the membrane does not deform the same way with each cast. If the fit of the individual cast had worse resdiuals than the group, they were reverted to the original group fit coefficients. SBE43 group fit coefficients. Coefficients were further refined station-by-station. ^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^ +---------+--------------+---------------+-------------------------+---------------+--------------+ | Station | S_oc | V_off | \tau_20 | T_cor | E | |=========|==============|===============|=========================|===============|==============| | 901-90 | 4.7574e-1 | -5.0079e-1 | 1.56 | -3.1680e-4 | 3.754e-2 | +---------+--------------+---------------+-------------------------+---------------+--------------+ CTD dissolved O_2 residuals are shown in the following figures O2 residuals versus station. through Deep O2 residuals versus station (Pressure >= 2000dbar).. [image]O_2 residuals versus station. [image]Deep O_2 residuals versus station (Pressure >= 2000dbar). [image]O_2 residuals versus pressure. The 95% confidence limits of 1.71 (µmol/kg) for all acceptable (flag 2) dissolved oxygen bottle data values and 1.52 (µmol/kg) for deep dissolved oxygen values are only presented as general indicators of the goodness of fit. CLIVAR GO-SHIP standards for CTD dissolved oxygen data are < 1% accuracy against on board Winkler titrated dissolved O_2 lab measurements. Minimal issues arose with the acquisition and processing of CTD dissolved oxygen data. * Fitting routines were not behaving well for certain stations. SBE43 data are not reported but will be further investigated on land. CTD Dissolved Oxygen (RINKO) ---------------------------- A two-point calibration was performed prior and after deployment on the rosette. These calibrations produced sets of calibration coefficients (G and H) to adjust factory calibration of dissolved oxygen raw voltage. The calibrations also provided an assessment of foil degradation over the course of the 90 stations. As per manufacturer (JFE Advantech Co., Ltd.) recommendation, 100% saturation points were obtained via bubbling ambient air in a stirred beaker of tap water about 30 minutes, removing air stone, then submersing the powered Rinko. Zero point calibrations also followed general manufacturer recommendations, using a sodium sulfite solution (25g in 500mL deionized water). Dissolved oxygen raw voltage (DOout), atmospheric pressure, and solution temperature were recorded for calculation of new oxygen sensor coefficients (G and H). Rinko temperature (factory coefficients) was used for pre-cruise calibration. Generally, the Rinko III sensor appears to have performed as expected with no major problems or sharp drift throughout the deployment. An SBE 43 dissolved oxygen sensor was deployed simultaneously. Both oxygen sensor data sets were analyzed and quality controlled with Winkler bottle oxygen data. RinkoIII data used as primary oxygen for all stations (1-90). RINKO data was acquired, converted from volts to oxygen saturation, and then multipled by the oxygen solubility to find values in µmol/kg. The resulting data were then fitted using the equations developed by [Uchida08]: [O_2] = (V_0 / V_c - 1) / K_{sv} K_{sv} = c_0 + c_1 T + c_2 T^2, \hspace{6pt} V_0 = 1 + d_0 T, \hspace{6pt} V_c = d_1 + d_2 V_r where: * T is temperature (ºC) * V_r is raw voltage (V) * V_0 is voltage at zero O_2 (V) * c_0, c_1, c_2, d_0, d_1, d_2 are calibration coefficients Oxygen is further corrected for pressure effects: [O_2]_c = [O_2] (1 + c_p P / 1000) ^ {1/3} where: * P is pressure (dbar) * c_p is pressure compensation coefficient Lastly, salinity corrections are applied [GarciaGordon1992]: [O_2]_{sc} = [O_2]_c \exp[{S (B_0 + B_1 T_S + B_2 T_S^2 + B_3 T_S^3) + C_0 S^2}] where: * T_S is scaled temperature (T_S = ln[(298.15 – T)/(273.15 + T)]) * B_0, B_1, B_2, B_3, C_0 are solubility coefficients All stations were fit together to get an initial coefficient estimate. Stations were then fit in groups of similar profiles to get a further refined estimate. Individual casts were then fit to remove the noticeable time drift in coefficients If the fit of the individual cast had worse resdiuals than the group, they were reverted to the original group fit coefficients. Rinko group fit coefficients. Coefficients were further refined station-by-station. ^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^ +--------------+--------------+--------------+--------------+--------------+--------------+--------------+--------------+ | Station | c_0 | c_1 | c_2 | d_0 | d_1 | d_2 | c_p | |==============|==============|==============|==============|==============|==============|==============|==============| | 901-29 | 1.8834 | 2.7106e-2 | 7.5022e-4 | 5.1571e-4 | -1.9373e-1 | 3.0792e-1 | 8.7822e-2 | +--------------+--------------+--------------+--------------+--------------+--------------+--------------+--------------+ | 30-72 | 1.8612 | 2.9074e-2 | 9.2059e-4 | 2.4233e-3 | -1.9987e-1 | 3.1466e-1 | 9.7739e-2 | +--------------+--------------+--------------+--------------+--------------+--------------+--------------+--------------+ | 73-90 | 1.8783 | 4.8992e-2 | 2.2758e-4 | 2.9361e-3 | -1.8483e-1 | 2.9822e-1 | 6.7778e-2 | +--------------+--------------+--------------+--------------+--------------+--------------+--------------+--------------+ CTD dissolved O_2 residuals are shown in the following figures. [image]O_2 residuals versus station. [image]Deep O_2 residuals versus station (Pressure >= 2000dbar). [image]O_2 residuals versus pressure. The 95% confidence limits of 1.27 (µmol/kg) for all acceptable (flag 2) dissolved oxygen bottle data values and 0.58 (µmol/kg) for deep dissolved oxygen values are only presented as general indicators of the goodness of fit. CLIVAR GO-SHIP standards for CTD dissolved oxygen data are < 1% accuracy against on board Winkler titrated dissolved O_2 lab measurements. No issues arose with the acquisition and processing of CTD dissolved oxygen data. [Mill82] Millard, R. C., Jr., “CTD calibration and data processing techniques at WHOI using the practical salinity scale,” Proc. Int. STD Conference and Workshop, p. 19, Mar. Tech. Soc., La Jolla, Ca. (1982). [Owen85] Owens, W. B. and Millard, R. C., Jr., “A new algorithm for CTD oxygen calibration,” Journ. of Am. Meteorological Soc., 15, p. 621 (1985). [Uchida08] Uchida, H., Kawano, T., Kaneko, I., Fukasawa, M. “In Situ Calibration of Optode-Based Oxygen Sensors,” J. Atmos. Oceanic Technol., 2271-2281, (2008) [GarciaGordon1992] García, H. E., and L. I. Gordon, 1992: Oxygen solubility in sea- water: Better fitting equations. Limnol. Oceanogr., 37, 1307– 1312. Salinity ======== PIs * Susan Becker (SIO) * James Swift (SIO) Technicians * John Calderwood (SIO) * Caitlyn Webster (SIO) Equipment and Techniques ------------------------ Two Guildline Autosals were on board and operational, SIO-owned 8400B S/N 69-180, and UW-owned 8400B S/N 94-894. S/N 69-180 was used for all salinity measurements during this cruise. The salinity analysis was run in the ship’s Climate Controlled Chamber, a refrigerator port and amidships between the Computer Lab and Bioanalytical Lab. The chamber temperature varied between about 21 and 25 degrees Celcius around 3 times each hour, with an average (based on measuring temperatures of items in the chamber) of about 23C. Both instruments were serviced prior to the cruise by their respective institutions and shipped to WHOI with other equipment in March. IAPSO Standard Seawater Batch P-166 was used for all calibrations: K15 =0.99985, salinity 34.994, expiration 2023-03-23. A LabView program developed by Carl Mattson was used for monitoring temperatures, logging data and prompting the operator. Salinity analyses were performed after samples had equilibrated to laboratory temperature of 23°C, usually 8 hours or more after collection. The salinometer was standardized for each group of samples analyzed (normally 1 or 2 casts, up to 72 samples) using two bottles of standard seawater: one at the beginning and one at the end of each set of measurements. Between runs the water from the last standard was left in the cell. For each calibration standard and sample reading, the salinometer cell was initially flushed at least 2 times before a set of conductivity ratio readings was recorded. Sampling and Data Processing ---------------------------- The salinity samples were collected in 200 ml Kimax high-alumina borosilicate bottles that had been rinsed at least three times with sample water prior to filling. The bottles were sealed with plastic insert thimbles and Nalgene screw caps. This assembly provides very low container dissolution and sample evaporation. Prior to sample collection, inserts were inspected for proper fit and loose inserts replaced to insure an airtight seal. Laboratory temperature was also monitored electronically throughout the cruise. PSS-78 salinity [UNESCO1981] was calculated for each sample from the measured conductivity ratios. The offset between the initial standard seawater value and its reference value was applied to each sample. Then the difference (if any) between the initial and final vials of standard seawater was applied to each sample as a function of elapsed run time. The corrected salinity data was then incorporated into the cruise database. Narrative --------- No major problems were encountered during this cruise. 2975 total salinity samples were taken from a test cast (5 samples) and 90 CTD casts (2970). Three sample bottles were broken during sampling. [UNESCO1981] UNESCO 1981. Background papers and supporting data on the Practical Salinity Scale, 1978. UNESCO Technical Papers in Marine Science, No. 37 144. Nutrients ========= Technicians * Susan Becker (SIO) * Alexandra Fine (AOML/CIMAS) Summary of Analysis ------------------- * 2977 samples from 90 CTD stations * The cruise started with new pump tubes and they were changed once, before station 033. * 2 sets of Primary/Secondary standards were made up over the course of the cruise. * The cadmium column efficiency was checked periodically and ranged between 85%-100%. Equipment and Techniques ------------------------ Nutrient analyses (phosphate, silicate, nitrate+nitrite, and nitrite) were performed on a Seal Analytical continuous-flow AutoAnalyzer 3 (AA3). The methods used are described by Gordon et al [Gordon1992] Hager et al. [Hager1972], and Atlas et al. [Atlas1971]. Details of modification of analytical methods used in this cruise are also compatible with the methods described in the nutrient section of the updated GO-SHIP repeat hydrography manual (Becker et al., 2019, [Becker 2019]_. Nitrate/Nitrite Analysis ------------------------ A modification of the Armstrong et al. (1967) [Armstrong1967] procedure was used for the analysis of nitrate and nitrite. For nitrate analysis, a seawater sample was passed through a cadmium column where the nitrate was reduced to nitrite. This nitrite was then diazotized with sulfanilamide and coupled with N-(1-naphthyl)-ethylenediamine to form a red dye. The sample was then passed through a 10mm flowcell and absorbance measured at 520nm. The procedure was the same for the nitrite analysis but without the cadmium column. **REAGENTS** Sulfanilamide Dissolve 10g sulfamilamide in 1.2N HCl and bring to 1 liter volume. Add 2 drops of 40% surfynol 465/485 surfactant. Store at room temperature in a dark poly bottle. Note: 40% Surfynol 465/485 is 20% 465 plus 20% 485 in DIW. N-(1-Naphthyl)-ethylenediamine dihydrochloride (N-1-N) Dissolve 1g N-1-N in DIW, bring to 1 liter volume. Add 2 drops 40% surfynol 465/485 surfactant. Store at room temperature in a dark poly bottle. Discard if the solution turns dark reddish brown. Imidazole Buffer Dissolve 13.6g imidazole in ~3.8 liters DIW. Stir for at least 30 minutes to completely dissolve. Add 60 ml of CuSO4 + NH4Cl mix (see below). Add 4 drops 40% Surfynol 465/485 surfactant. Let sit overnight before proceeding. Using a calibrated pH meter, adjust to pH of 7.83-7.85 with 10% (1.2N) HCl (about 10 ml of acid, depending on exact strength). Bring final solution to 4L with DIW. Store at room temperature. NH4Cl + CuSO4 mix Dissolve 2g cupric sulfate in DIW, bring to 100 m1 volume (2%). Dissolve 250g ammonium chloride in DIW, bring to 1l liter volume. Add 5ml of 2% CuSO4 solution to this NH4Cl stock. This should last many months. Phosphate Analysis ------------------ Ortho-Phosphate was analyzed using a modification of the Bernhardt and Wilhelms (1967) [Bernhardt1967] method. Acidified ammonium molybdate was added to a seawater sample to produce phosphomolybdic acid, which was then reduced to phosphomolybdous acid (a blue compound) following the addition of dihydrazine sulfate. The sample was passed through a 10mm flowcell and absorbance measured at 820nm. **REAGENTS** Ammonium Molybdate H2SO4 sol’n Pour 420 ml of DIW into a 2 liter Ehrlenmeyer flask or beaker, place this flask or beaker into an ice bath. SLOWLY add 330 ml of conc H2SO4. This solution gets VERY HOT!! Cool in the ice bath. Make up as much as necessary in the above proportions. Dissolve 27g ammonium molybdate in 250ml of DIW. Bring to 1 liter volume with the cooled sulfuric acid sol’n. Add 3 drops of 15% DDS surfactant. Store in a dark poly bottle. Dihydrazine Sulfate Dissolve 6.4g dihydazine sulfate in DIW, bring to 1 liter volume and refrigerate. Silicate Analysis ----------------- Silicate was analyzed using the basic method of Armstrong et al. (1967). Acidified ammonium molybdate was added to a seawater sample to produce silicomolybdic acid which was then reduced to silicomolybdous acid (a blue compound) following the addition of stannous chloride. The sample was passed through a 10mm flowcell and measured at 660nm. **REAGENTS** Tartaric Acid Dissolve 200g tartaric acid in DW and bring to 1 liter volume. Store at room temperature in a poly bottle. Ammonium Molybdate Dissolve 10.8g Ammonium Molybdate Tetrahydrate in 1000ml dilute H2SO4. (Dilute H2SO4 = 2.8ml conc H2SO4 or 6.4ml of H2SO4 diluted for PO4 moly per liter DW) (dissolve powder, then add H2SO4) Add 3-5 drops 15% SDS surfactant per liter of solution. Stannous Chloride stock: (as needed) Dissolve 40g of stannous chloride in 100 ml 5N HCl. Refrigerate in a poly bottle. NOTE: Minimize oxygen introduction by swirling rather than shaking the solution. Discard if a white solution (oxychloride) forms. working: (every 24 hours) Bring 5 ml of stannous chloride stock to 200 ml final volume with 1.2N HCl. Make up daily - refrigerate when not in use in a dark poly bottle. Sampling -------- Nutrient samples were drawn into 30 ml polypropylene screw-capped centrifuge tubes. The tubes and caps were cleaned with 10% HCl and rinsed 2-3 times with sample before filling. Samples were analyzed within 4 hours after sample collection, allowing sufficient time for all samples to reach room temperature. The centrifuge tubes fit directly onto the sampler. Data Collection and Processing ------------------------------ Data collection and processing was done with the software provided with the instrument from Seal Analytical (AACE). After each run, the charts were reviewed for any problems during the run, any blank was subtracted, and final concentrations (micro moles/liter) were calculated, based on a linear curve fit. Once the run was reviewed and concentrations calculated a text file was created. That text file was reviewed for possible problems and then converted to another text file with only sample identifiers and nutrient concentrations that was merged with other bottle data. Standards and Glassware Calibration ----------------------------------- Primary standards for silicate (Na2SiF6), nitrate (KNO3), nitrite (NaNO2), and phosphate (KH2PO4) were obtained from Johnson Matthey Chemical Co. and/or Fisher Scientific. The supplier reports purities of >98%, 99.999%, 97%, and 99.999 respectively. All glass volumetric flasks and pipettes were gravimetrically calibrated prior to the cruise. The primary standards were dried and weighed out to 0.1mg prior to the cruise. The exact weight was noted for future reference. When primary standards were made, the flask volume at 20C, the weight of the powder, and the temperature of the solution were used to buoyancy-correct the weight, calculate the exact concentration of the solution, and determine how much of the primary was needed for the desired concentrations of secondary standard. The new standards were compared to the old before use. All the reagent solutions, primary and secondary standards were made with fresh distilled deionized water (DIW). Standardizations were performed at the beginning of each group of analyses with working standards prepared every 12-16 hours from a secondary. Working standards were made up in low nutrient seawater (LNSW). Two batches of LNSW were used on the cruise. The first batch of LNSW was treated in the lab. The water was re-circulated for ~8 hours through a 0.2 micron filter, passed a UV lamp and through a second 0.2 micron filter. The actual concentration of nutrients in this water was empirically determined during the standardization calculations. The concentrations in micro-moles per liter of the working standards used were: +-----+-------+-------+-------+-------+ | - | N+N | PO_4 | SIL | NO_2 | | | (uM) | (uM) | (uM) | (uM) | |=====|=======|=======|=======|=======| | 0 | 0.0 | 0.0 | 0.0 | 0.0 | +-----+-------+-------+-------+-------+ | 3 | 15.50 | 1.2 | 60 | 0.50 | +-----+-------+-------+-------+-------+ | 5 | 31.00 | 2.4 | 120 | 1.00 | +-----+-------+-------+-------+-------+ | 7 | 46.50 | 3.6 | 180 | 1.50 | +-----+-------+-------+-------+-------+ Quality Control --------------- All final data was reported in micro-moles/kg. NO_3, PO_4, and NO_2 were reported to two decimals places and SIL to one. Accuracy is based on the quality of the standards the levels are: +-------+-----------------------------+ | NO_3 | 0.05 µM (micro moles/Liter) | +-------+-----------------------------+ | PO_4 | 0.004 µM | +-------+-----------------------------+ | SIL | 2-4 µM | +-------+-----------------------------+ | NO_2 | 0.05 µM | +-------+-----------------------------+ The deep check sample that is normally run was discontinued due to issues with cadmium column efficiency on A20. It is thought the mercuric chloride may have been contributing to the loss of column efficiency. Reference materials for nutrients in seawater (RMNS) were used as a check sample run with every station. The RMNS preparation, verification, and suggested protocol for use of the material are described by [Aoyama2006] [Aoyama2007], [Aoyama2008], Sato [Sato2010] and Becker et al. [Becker 2019]. RMNS batch C0 was used on this cruise, with each bottle being used for all runs in one day before being discarded and a new one opened. Data are tabulated below. +-----------+---------------+---------+---------------+ | Parameter | Concentration | stddev | assigned conc | |===========|===============|=========|===============| | - | (µmol/kg) | - | (µmol/kg) | +-----------+---------------+---------+---------------+ | NO_3 | 15.86 | 0.02 | 15.86 | +-----------+---------------+---------+---------------+ | PO_4 | 1.17 | 0.005 | 1.177 | +-----------+---------------+---------+---------------+ | Sil | 34.7 | 0.12 | 34.72 | +-----------+---------------+---------+---------------+ | NO_2 | 0.04 | 0.005 | 0.04 | +-----------+---------------+---------+---------------+ Analytical Problems ------------------- There were issues with the cadmium column efficiency on A20. The exact issue was never clearly identified but it appears to have been a combination of buffer that was not stable which affected the efficiency and life span of the cadmium reduction columns. The values of the reference material and the were used to in addition to the periodic column efficiency checks to monitor data quality. Adjustments based on the values obtained for the references material were made as necessary. The adjusted data for affected stations was compared to adjacent stations and historical data during the final QC checks. [Armstrong1967] Armstrong, F.A.J., Stearns, C.A., and Strickland, J.D.H., “The measurement of upwelling and subsequent biological processes by means of the Technicon Autoanalyzer and associated equipment,” Deep-Sea Research, 14, pp.381-389 (1967). [Atlas1971] Atlas, E.L., Hager, S.W., Gordon, L.I., and Park, P.K., “A Practical Manual for Use of the Technicon AutoAnalyzer in Seawater Nutrient Analyses Revised,” Technical Report 215, Reference 71-22, p.49, Oregon State University, Department of Oceanography (1971). [Aoyama2006] Aoyama, M., 2006: 2003 Intercomparison Exercise for Reference Material for Nutrients in Seawater in a Seawater Matrix, Technical Reports of the Meteorological Research Institute No.50, 91pp, Tsukuba, Japan. [Aoyama2007] Aoyama, M., Susan B., Minhan, D., Hideshi, D., Louis, I. G., Kasai, H., Roger, K., Nurit, K., Doug, M., Murata, A., Nagai, N., Ogawa, H., Ota, H., Saito, H., Saito, K., Shimizu, T., Takano, H., Tsuda, A., Yokouchi, K., and Agnes, Y. 2007. Recent Comparability of Oceanographic Nutrients Data: Results of a 2003 Intercomparison Exercise Using Reference Materials. Analytical Sciences, 23: 1151-1154. [Aoyama2008] Aoyama M., J. Barwell-Clarke, S. Becker, M. Blum, Braga E. S., S. C. Coverly,E. Czobik, I. Dahllof, M. H. Dai, G. O. Donnell, C. Engelke, G. C. Gong, Gi-Hoon Hong, D. J. Hydes, M. M. Jin, H. Kasai, R. Kerouel, Y. Kiyomono, M. Knockaert, N. Kress, K. A. Krogslund, M. Kumagai, S. Leterme, Yarong Li, S. Masuda, T. Miyao, T. Moutin, A. Murata, N. Nagai, G.Nausch, M. K. Ngirchechol, A. Nybakk, H. Ogawa, J. van Ooijen, H. Ota, J. M. Pan, C. Payne, O. Pierre-Duplessix, M. Pujo-Pay, T. Raabe, K. Saito, K. Sato, C. Schmidt, M. Schuett, T. M. Shammon, J. Sun, T. Tanhua, L. White, E.M.S. Woodward, P. Worsfold, P. Yeats, T. Yoshimura, A.Youenou, J. Z. Zhang, 2008: 2006 Intercomparison Exercise for Reference Material for Nutrients in Seawater in a Seawater Matrix, Technical Reports of the Meteorological Research Institute No. 58, 104pp. [Bernhardt1967] Bernhardt, H., and Wilhelms, A., “The continuous determination of low level iron, soluble phosphate and total phosphate with the AutoAnalyzer,” Technicon Symposia, I,pp.385-389 (1967). [Gordon1992] Gordon, L.I., Jennings, J.C., Ross, A.A., Krest, J.M., “A suggested Protocol for Continuous Flow Automated Analysis of Seawater Nutrients in the WOCE Hydrographic Program and the Joint Global Ocean Fluxes Study,” Grp. Tech Rpt 92-1, OSU College of Oceanography Descr. Chem Oc. (1992). [Hager1972] Hager, S.W., Atlas, E.L., Gordon L.I., Mantyla, A.W., and Park, P.K., ” A comparison at sea of manual and autoanalyzer analyses of phosphate, nitrate, and silicate ,” Limnology and Oceanography, 17,pp.931-937 (1972). [Kerouel1997] Kerouel, R., Aminot, A., “Fluorometric determination of ammonia in sea and estuarine waters by direct segmented flow analysis.” Marine Chemistry, vol 57, no. 3-4, pp. 265-275, July 1997. [Sato2010] Sato, K., Aoyama, M., Becker, S., 2010. RMNS as Calibration Standard Solution to Keep Comparability for Several Cruises in the World Ocean in 2000s. In: Aoyama, M., Dickson, A.G., Hydes, D.J., Murata, A., Oh, J.R., Roose, P., Woodward, E.M.S., (Eds.), Comparability of nutrients in the world’s ocean. Tsukuba, JAPAN: MOTHER TANK, pp 43-56. Oxygen Analysis =============== PIs * Susan Becker (SIO) * James Swift (SIO) Technicians * Andrew Barna (SIO) * Robert “Ben” Freiberger (SIO) Equipment and Techniques ------------------------ Dissolved oxygen analyses were performed with an SIO/ODF-designed automated oxygen titrator using photometric end-point detection based on the absorption of 365nm wavelength ultra-violet light. The titration of the samples and the data logging were controlled by PC LabView software. Thiosulfate was dispensed by a Dosimat 665 buret driver fitted with a 1.0 ml burette. ODF used a whole-bottle modified-Winkler titration following the technique of Carpenter [Carpenter1965] with modifications by [Culberson1991] but with higher concentrations of potassium iodate standard (~0.012 N), and thiosulfate solution (~55 g/L). Pre-made liquid potassium iodate standards and reagent/distilled water blanks were run every day (approximately every 3-4 stations), with samples analysed within 24 hours of the last standard. Sampling and Data Processing ---------------------------- A total of 2969 oxygen measurements were made, all of which were niskin samples. There are no underway samples. Niskin samples were collected soon after the rosette was secured on deck, either from fresh niskins or immediately following CFC sampling. Nominal 125 mL volume-calibrated biological oxygen demand (BOD) flasks were rinsed 3 times with minimal agitation using a silicone draw tube, then filled and allowed to overflow for at least 3 flask volumes, ensuring no bubbles remained. Pickling reagents MnCl2 and NaI/NaOH (1 mL of each) were added via bottle-top dispensers to fix samples before stoppering. Flasks were shaken twice (10-12 inversions) to assure thorough dispersion of the precipitate - once immediately after drawing and then again after 30-60 minutes. Sample draw temperatures, measured with an electronic resistance temperature detector (RTD) embedded in the draw tube, were used to calculate umol/kg concentrations, and as a diagnostic check of bottle integrity. Niskin samples were analysed within 2-12 hours of collection, and the data incorporated into the cruise database. Underway samples were analysed within 96 hours of collection. Thiosulfate normalities were calculated for each standardisation and corrected to 20°C. The 20°C thiosulfate normalities and blanks were plotted versus time and were reviewed for possible problems, and were subsequently determined to be stable enough that no smoothing was required. Volumetric Calibration ---------------------- Oxygen flask volumes were determined gravimetrically with degassed deionised water to determine flask volumes at ODF’s chemistry laboratory. This is done once before using flasks for the first time and periodically thereafter when a suspect volume is detected. The 10 mL Dosimat buret used to dispense standard iodate solution was calibrated using the same method. Standards --------- Liquid potassium iodate standards were prepared in 6 L batches and bottled in sterile glass bottles at ODF’s chemistry laboratory prior to the expedition. The normality of the liquid standard was determined by calculation from weight. The standard was supplied by Alfa Aesar and has a reported purity of 99.4-100.4%. All other reagents were “reagent grade” and were tested for levels of oxidising and reducing impurities prior to use. Narrative --------- The analytical rig remained set up from the just completed 2021 occupation of A20. This included all the reagents, though more NaI/OH and MnCl2 were made while in port. The thiosulfate stability was considered in 4 batches and showed remarkable stability throughout the entire cruise. No trends were observed or corrected for. There was a freezing concern regarding the liquid reagents shipped to WHOI prior to the start of A20. To verify that our standards were good, some OSIL KIO3 standard was shipped to the US Virgin Islands to load during the port call. These standards were all run during the transit around Puerto Rico (between stations 29 and 30). All the ODF standards agreed with each other, the OSIL standards were inconclusive. Though perhaps the lesson learned was that the lead analyst lacked sufficient skill with hand pipettes to use them. No data updates are expected. [image]Bottle oxygen data gridded on isopycnals. [Carpenter1965] Carpenter, J. H., “The Chesapeake Bay Institute technique for the Winkler dissolved oxygen method,” Limnology and Oceanography, 10, pp. 141-143 (1965). [Culberson1991] Culberson, C. H., Knapp, G., Stalcup, M., Williams, R. T., and Zemlyak, F., “A comparison of methods for the deter mination of dissolved oxygen in seawater,” Repor t WHPO 91-2, WOCE Hydrographic Programme Office (Aug 1991). Total Alkalinity ================ PIs * Andrew G. Dickson (SIO) * Frank J. Millero (RSMAS) Technicians * Carmen Rodriguez (RSMAS) * Daniela Nestory (SIO) Total Alkalinity ---------------- The total alkalinity of sea water is defined as the number of moles of hydrogen ion equivalent to the excess of proton acceptors (bases formed from weak acids with a dissociation constant K < 10E-4.5 at 25°C and zero ionic strength) over proton donors (acids with K > 10E-4.5) in 1 kilogram of sample. Total Alkalinity Measurement System ----------------------------------- *Sample Delivery System:* Samples are dispensed using a Sample Delivery System (SDS) which has been calibrated for volume in the lab prior to the cruise. Its volume is confirmed immediately before use at sea to ensure a consistent volume will be delivered for each sample. The SDS consists of a volumetric pipette, various relay valves, an air pump, and is controlled by a program in LabVIEW 2012. Before attaching a sample bottle to the SDS, the volumetric pipette is cleared of any residual solution. The pipette is then rinsed and filled with the sample. The sample overflows and time is allowed for the sample temperature to equilibrate. The sample bottle temperature is measured using a DirecTemp thermistor probe inserted into the sample bottle and the volumetric pipette temperature is measured using a DirecTemp surface probe placed directly on the pipette. These temperature measurements, along with the bottle salinity, are used to convert the sample volume to mass for analysis. Samples are delivered into a 250-mL water-jacketed open cell for titration analysis. While one sample is undergoing titration, a second sample is prepared with the SDS and equilibrated to 20°C for analysis. *Open-Cell Titration:* The total alkalinity is measured through an open-cell titration with a dilute hydrochloric acid titrant of known concentration. A Metrohm 876 Dosimat Plus is used for all standardized hydrochloric acid additions. An initial aliquot of approximately 2.3-2.4 mL of standardized hydrochloric acid (~0.1M HCl in ~0.6M NaCl solution) is first delivered and the sample is stirred for 5 minutes while air is bubbled into at a rate of 200 scc/m to remove any liberated carbon dioxide gas. After equilibration, ~19 aliquots of 0.035 ml are added. Between the pH range of 3.5 to 3.0, the progress of the titration is monitored using a pH glass electrode/reference electrode cell, and the total alkalinity is computed from the titrant volume and e.m.f. measurements using a non-linear least-squares approach (Dickson, 2007). A Thermo Scientific Isotemp water bath is connected to the water- jacketed open cell to maintain a cell temperature of approximately 20oC. An Agilent 34970A Data Acquisition/Switch Unit with a 34901A multiplexer is used to read the voltage measurements from the electrode and monitor the temperatures from the sample, acid, and room. The calculations for this procedure are performed automatically using LabVIEW 2012. Sample Collection ----------------- Alkalinity samples are drawn using silicone tubing connected to the Niskin bottles and collected into 250 mL Pyrex bottles. The sample bottles and Teflon-sleeved glass stoppers were rinsed at least twice before the final filling. A headspace of approximately 3 mL was removed and 0.05 mL of saturated mercuric chloride solution was added to each sample for preservation. The samples were equilibrated prior to analysis at approximately 20°C using a Thermo Scientific Isotemp water bath. Samples for total alkalinity were taken at all stations during A22 (1-90). Except for a few instances, alkalinity samples were collected from each niskin where DIC and pH were collected, to over-characterize the CO2 system. The typical sample scheme of full collection on even- numbered stations (36 niskin bottles) and partial collection (~8-20 bottles) on odd-numbered stations was followed. In order to evaluate the reproducibility of the alkalinity system, duplicate samples (two separate alkalinity bottles) were collected at a minimum of 10% of total samples. For instance, when all 36 niskins were sampled, 3 duplicate samples were collected for alkalinity. When alkalinity sampled a partial cast, one or two duplicate samples were collected. Problems and Troubleshooting ---------------------------- There were a few issues encountered at the start of the cruise which delayed sample processing but did not impede sample intake. It was determined that the SDS_A system, which had been used on Leg 1 (A20), was leaking and further use would be problematic for this leg. The spare system (SDS_B) was swapped in and extra time was needed to confirm the accuracy and stability of the replacement SDS. Surplus alkalinity bottles were available to stockpile samples so productivity was not impeded. Also at the start of the cruise, an error in the Labview program’s file creation resulted in configuration equations being omitted which had to be reinput by hand initially. A typo in the input equations was soon discovered and corrected. The SDS system occasionally freezes at different points in the procedure. However the technicians were alert to this issue and were able to save most samples when this occurred. Although the temperature in the lab was very stable for the majority of the cruise, just before entering the Gulf Stream (starting at station 71), the room temperature dropped by approximately 2oC. The acid temperature dropped as well, causing errors in the calculations. The engineers of the R/V TG Thompson worked to increase and stabilize the room temperature. The cool climate continued for a couple of days, so time was spent to combat temperature instability. Samples were not run when the appropriate range in temperature could not be achieved. Quality Control --------------- Certified Reference Material (CRMs) and duplicate samples (two bottles collected from one niskin) were used to quality check the functioning of the total alkalinity system throughout the cruise. Dickson laboratory Certified Reference Material (CRM) Batches 178 and 192 were used to determine the accuracy of the total alkalinity analyses. The total alkalinity certified value for these batches are: * Batch 178: 2216.53 ± 0.61 µmol/kg (132; 75) * Batch 192 2213.70 ± 0.53 µmol/kg (132; 67) The cited uncertainties represent the standard deviation. Figures in parentheses are the number of analyses made (total number of analyses; number of separate bottles analyzed). A CRM sample was analyzed at a minimum frequency of once per every 20 runs, but more often once per every 15 runs. Because total alkalinity is not affected by gas-exchange, brand new CRM bottles were reserved for pH and DIC analysis. These pre-opened bottles were subsequently used for alkalinity analysis. 264 reference material samples were analyzed on A22. The average measured total alkalinity value for each batch is: * Batch 178: 2217.97 ± 1.99 µmol kg-1 (n = 132) * Batch 192: 2214.40 ± 1.80 µmol kg-1 (n = 132) Duplicate samples were also used to check the reproducibility of the system. The absolute value of the mean offset between duplicate samples and the standard deviation are given below. Mean duplicate sample offset: 1.35 ± 1.03 µmol kg-1 (n = 161) 1884 total alkalinity values were submitted for A22. Further dilution corrections need to be applied to this data back onshore, therefore, this data is to be considered preliminary. Dissolved Inorganic Carbon (DIC) ================================ PI’s * Rik Wanninkhof (NOAA/AOML) * Richard A. Feely (NOAA/PMEL) Technicians * Charles Featherstone (NOAA/AOML) * Andrew Collins (NOAA/PMEL) Sample Collection ----------------- Samples for DIC measurements were drawn (according to procedures outlined in the PICES Publication, *Guide to Best Practices for Ocean CO2 Measurements* [Dickson2007]) from Niskin bottles into 294 ml borosilicate glass bottles using silicone tubing. The flasks were rinsed once and filled from the bottom with care not to entrain any bubbles, overflowing by at least one-half volume. The sample tube was pinched off and withdrawn, creating a 6 ml headspace, followed by 0.12 ml of saturated HgCl_2 solution which was added as a preservative. The sample bottles were then sealed with glass stoppers lightly covered with Apiezon-L grease and were stored at room temperature for a maximum of 12 hours. Equipment --------- The analysis was done by coulometry with two analytical systems (AOML 3 and AOML 4) used simultaneously on the cruise. Each system consisted of a coulometer (CM5017 UIC Inc) coupled with a Dissolved Inorganic Carbon Extractor (DICE). The DICE system was developed by Esa Peltola and Denis Pierrot of NOAA/AOML and Dana Greeley of NOAA/PMEL to modernize a carbon extractor called SOMMA ([Johnson1985], [Johnson1987], [Johnson1993], [Johnson1992], [Johnson1999]). The two DICE systems (AOML 3 and AOML 4) were set up in a seagoing container modified for use as a shipboard laboratory on the aft main working deck of the R/V Thomas G Thompson. DIC Analysis ------------ In coulometric analysis of DIC, all carbonate species are converted to CO_2 (gas) by addition of excess hydrogen ion (acid) to the seawater sample, and the evolved CO_2 gas is swept into the titration cell of the coulometer with pure air or compressed nitrogen, where it reacts quantitatively with a proprietary reagent based on ethanolamine to generate hydrogen ions. In this process, the solution changes from blue to colorless, triggering a current through the cell and causing coulometrical generation of OH^- ions at the anode. The OH^- ions react with the H^+ and the solution turns blue again. A beam of light is shone through the solution, and a photometric detector at the opposite side of the cell senses the change in transmission. Once the percent transmission reaches its original value, the coulometric titration is stopped, and the amount of CO_2 that enters the cell is determined by integrating the total change during the titration. DIC Calculation --------------- Calculation of the amount of CO2 injected was according to the CO2 handbook [DOE1994]. The concentration of CO2 ([CO2]) in the samples was determined according to: [\text{CO}_2] = \text{Cal. Factor} * \frac{(\text{Counts} - \text{Blank} * \text{Run Time}) * K \mu\text{mol}/\text{count}}{\text{pipette volume} * \text{density of sample}} where Cal. Factor is the calibration factor, Counts is the instrument reading at the end of the analysis, Blank is the counts/minute determined from blank runs performed at least once for each cell solution, Run Time is the length of coulometric titration (in minutes), and K is the conversion factor from counts to micromoles. The instrument has a salinity sensor, but all DIC values were recalculated to a molar weight (µmol/kg) using density obtained from the CTD’s salinity. The DIC values were corrected for dilution due to the addition of 0.12 ml of saturated HgCl_2 used for sample preservation. The total water volume of the sample bottles was 294 ml (calibrated by Esa Peltola, AOML). The correction factor used for dilution was 1.00041. A correction was also applied for the offset from the CRM. This additive correction was applied for each cell using the CRM value obtained at the beginning of the cell. The average correction was 1.51 µmol/kg for AOML 3 and 1.06 µmol/kg for AOML 4. The coulometer cell solution was replaced after 24-28 mg of carbon was titrated, typically after 9-12 hours of continuous use. The blanks ranged from 12-55. Calibration, Accuracy, and Precision ------------------------------------ The stability of each coulometer cell solution was confirmed three different ways. 1. Gas loops were run at the beginning of each cell 2. CRM’s supplied by Dr. A. Dickson of SIO, were analyzed at the beginning of the cell before sample analysis. 3. Duplicate samples from the same niskin, were measured near the beginning; middle and end of each cell. Each coulometer was calibrated by injecting aliquots of pure CO_2 (99.999%) by means of an 8-port valve [Wilke1993] outfitted with two calibrated sample loops of different sizes (~1ml and ~2ml). The instruments were each separately calibrated at the beginning of each cell with a minimum of two sets of these gas loop injections. The accuracy of the DICE measurement is determined with the use of standards (Certified Reference Materials (CRMs), consisting of filtered and UV irradiated seawater) supplied by Dr. A. Dickson of Scripps Institution of Oceanography (SIO). The CRM accuracy is determined manometrically on land in San Diego and the DIC data reported to the data base have been corrected to this batch 178 CRM value. The CRM certified value for this batch is 1952.65 µmol/kg. The precision of the two DICE systems can be demonstrated via the replicate samples. Approximately 10% of the niskins sampled were duplicates taken as a check of our precision. These replicate samples were interspersed throughout the station analysis for quality assurance and integrity of the coulometer cell solutions. The average absolute difference of these replicates was 1.34 (AOML 3) and 1.49 (AOML 4) µmol/kg - No major systematic differences between the replicates were observed. The pipette volume was determined by taking aliquots of distilled water from volumes at known temperatures. The weights with the appropriate densities were used to determine the volume of the pipettes. Calibration data during this cruise: +---------+---------------------+------------+-----------------+-----------+----------------------+ | UNIT | Ave Gas Cal Factor | Pipette | Ave CRM | Std Dev | Ave Difference Dupes | |=========|=====================|============|=================|===========|======================| | AOML3 | 1.00390 | 27.990 ml | 1953.24, N = 43 | 1.14 | 1.34 | +---------+---------------------+------------+-----------------+-----------+----------------------+ | AOML4 | 1.00313 | 29.387 ml | 1952.20, N = 41 | 1.25 | 1.49 | +---------+---------------------+------------+-----------------+-----------+----------------------+ Instrument Repairs ------------------ AOML 3 had a relay switch failure before Station 41. The relay switch and micro acid pump were replaced and the instrument functioned well for the rest of the cruise. The pipette was not filling properly before Station 54. Valve 13 was found to be defective and replaced which corrected the filling of the pipette. AOML 3 functioned well for the remainder of the cruise. Summary ------- The overall performance of the analytical equipment was good during the cruise. Including the duplicates, a total of 2208 samples were analyzed from 90 CTD casts for dissolved inorganic carbon (DIC), which equates to a DIC value for 68% of the niskins tripped. The DIC data reported to the database directly from the ship are to be considered preliminary until a more thorough quality assurance can be completed shore side. [DOE1994] DOE (U.S. Department of Energy). (1994). *Handbook of Methods for the Analysis of the Various Parameters of the Carbon Dioxide System in Seawater*. Version 2.0. ORNL/CDIAC-74. Ed. A. G. Dickson and C. Goyet. Carbon Dioxide Information Analysis Center, Oak Ridge National Laboratory, Oak Ridge, Tenn. [Dickson2007] Dickson, A.G., Sabine, C.L. and Christian, J.R. (Eds.), (2007): *Guide to Best Practices for Ocean CO2 Measurements*. PICES Special Publication 3, 191 pp. [Feely1998] Feely, R.A., R. Wanninkhof, H.B. Milburn, C.E. Cosca, M. Stapp, and P.P. Murphy (1998): *“A new automated underway system for making high precision pCO2 measurements aboard research ships.”* Anal. Chim. Acta, 377, 185-191. [Johnson1985] Johnson, K.M., A.E. King, and J. McN. Sieburth (1985): *“Coulometric DIC analyses for marine studies: An introduction.”* Mar. Chem., 16, 61-82. [Johnson1987] Johnson, K.M., P.J. Williams, L. Brandstrom, and J. McN. Sieburth (1987): *“Coulometric total carbon analysis for marine studies: Automation and calibration.”* Mar. Chem., 21, 117-133. [Johnson1992] Johnson, K.M. (1992): Operator’s manual: *“Single operator multiparameter metabolic analyzer (SOMMA) for total carbon dioxide (CT) with coulometric detection.”* Brookhaven National Laboratory, Brookhaven, N.Y., 70 pp. [Johnson1993] Johnson, K.M., K.D. Wills, D.B. Butler, W.K. Johnson, and C.S. Wong (1993): *“Coulometric total carbon dioxide analysis for marine studies: Maximizing the performance of an automated continuous gas extraction system and coulometric detector.”* Mar. Chem., 44, 167-189. [Johnson1999] Johnson, K.M., Körtzinger, A.; Mintrop, L.; Duinker, J.C.; and Wallace, D.W.R. (1999). *Coulometric total carbon dioxide analysis for marine studies: Measurement and interna consistency of underway surface TCO2 concentrations.* Marine Chemistry 67:123–44. [Lewis1998] Lewis, E. and D. W. R. Wallace (1998) Program developed for CO2 system calculations. Oak Ridge, Oak Ridge National Laboratory. http://cdiac.ornl.gov/oceans/co2rprt.html [Wilke1993] Wilke, R.J., D.W.R. Wallace, and K.M. Johnson (1993): “Water-based gravimetric method for the determination of gas loop volume.” Anal. Chem. 65, 2403-2406 Discrete pH Analyses (Total Scale) ================================== PI * Dr. Andrew Dickson (SIO) * Dr. Frank Millero (RSMAS) Technicians * Sidney Wayne (HPU) * Albert Ortiz (RSMAS) Sampling -------- Samples were collected in 250 mL Pyrex glass bottles and sealed using grey butyl rubber stoppers held in place by aluminum-crimped caps. Each bottle was rinsed two times and allowed to overflow by one half additional bottle volume. Prior to sealing, each sample was given a 1% headspace and poisoned with 0.02% of the sample volume of saturated mercuric chloride (HgCl_2). Samples were collected only from Niskin bottles that were also being sampled for both total alkalinity and dissolved inorganic carbon in order to completely characterize the carbon system. Additionally, duplicate samples were collected from all stations for quality control purposes. Analysis -------- pH was measured spectrophotometrically on the total hydrogen scale using an Agilent 8453 spectrophotometer and in accordance with the methods outlined by Carter et al, 2013. [Carter2013]. A Kloehn V6 syringe pump was used to autonomously fill, mix, and dispense sample through the custom 10cm flow-through jacketed cell. A Thermo Fisher Isotemp recirculating water bath was used to maintain the cell temperature at 25.0°C during analyses, and a YSI 4600 precision thermometer and probe were used to monitor and record the temperature of each sample during the spectrophotometric measurements. Purified meta-cresol purple (mCP) was the indicator used to measure the absorbance of light measured at two different wavelengths (434 nm, 578 nm) corresponding to the maximum absorbance peaks for the acidic and basic forms of the indicator dye. A baseline absorbance was also measured and subtracted from these wavelengths. The baseline absorbance was determined by averaging the absorbances from 725-735nm. The ratio of the absorbances was then used to calculate pH on the total scale using the equations outlined in Liu et al., 2011 [Liu2011]. The salinity data used was obtained from the salinity analysis conducted on board. Reagents -------- The mCP indicator dye was made up to a concentration of approximately 2.0mM and a total ionic strength of 0.7 M. A total of two batches were used during A22. The pHs of these batches were adjusted with 0.1 mol kg^-1 solutions of HCl and NaOH (in 0.6 mol kg^-1 NaCl background) to approximately 7.80, measured with a pH meter calibrated with NBS buffers. The indicator was obtained from Dr. Robert Byrne at the University of Southern Florida and was purified using the flash chromatography technique described by Patsavas et al., 2013. [Patsavas2013]. Data Processing --------------- An indicator dye is itself an acid-base system that can change the pH of the seawater to which it is added. Therefore it is important to estimate and correct for this perturbation to the seawater’s pH for each batch of dye used during the cruise. To determine this correction, multiple bottles from each station were measured twice, once with a single addition of indicator dye and once with a double addition of indicator dye. The measured absorbance ratio (R) and an isosbestic absorbance (A_{\text{iso}}) were determined for each measurement, where: R = \frac{A_{578} - A_{\text{base}}}{A_{434} - A_{\text{base}}} and A_{\text{iso}} = A_{488} - A_{\text{base}} The change in R for a given change in A_{\text{iso}}, \Delta R/\Delta A_{\text{iso}}, was then plotted against the measured R-value for the normal amount of dye and fitted with a linear regression. From this fit the slope and y-intercept (b and a respectively) are determined by: \Delta R/\Delta A_{\text{iso}} = bR + a From this the corrected ratio (R') corresponding to the measured absorbance ratio if no indicator dye were present can be determined by: R' = R - A_{\text{iso}} (bR + a) Problems and Troubleshooting ---------------------------- During the beginning of the cruise, the sample cell was broken due to stress on the sample inlet glass tubes, but the lead tech was able to rig the cell to remain operable. Standardization/Results ----------------------- The precision of the data was assessed from measurements of duplicate analyses, replicate analyses (two successive measurements on one bottle), and certified reference material (CRM) Batch 192 (provided by Dr. Andrew Dickson, UCSD). two or three duplicates and one or two replicate measurements were performed on every station when at least twenty-four Niskins were sampled. If less than twenty-four Niskins were sampled, only one or two duplicates and one replicate measurement were performed. CRMs were measured at the beginning and ending of each day. The precision statistics for A22 are: +----------------------------+--------------------------+ | Duplicate precision | ± 0.0009 (n=190) | +----------------------------+--------------------------+ | Replicate precision | ± 0.0010 (n=104) | +----------------------------+--------------------------+ | B192 | 7.7493 ± 0.0016 (n=47) | +----------------------------+--------------------------+ | B192 within-bottle SD | ± 0.0010 (n=47) | +----------------------------+--------------------------+ 2001 pH values were submitted for A22. Additional corrections will need to be performed and these data should be considered preliminary until a more thorough analysis of the data can take place on shore. [Carter2013] Carter, B.R., Radich, J.A., Doyle, H.L., and Dickson, A.G., “An Automated Spectrometric System for Discrete and Underway Seawater pH Measurements,” Limnology and Oceanography: Methods, 2013. [Liu2011] Liu, X., Patsavas, M.C., Byrne R.H., “Purification and Characterization of meta Cresol Purple for Spectrophotometric Seawater pH Measurements,” Environmental Science and Technology, 2011. [Patsavas2013] Patsavas, M.C., Byrne, R.H., and Liu X. “Purification of meta-cresol purple and cresol red by flash chromatography: Procedures for ensuring accurate spectrophotometric seawater pH measurements,” Marine Chemistry, 2013. CFC, SF_6, and N_2O =================== PIs * Mark J. Warner (UW) Analysts * Mark J. Warner (UW) * Bonnie X. Chang (UW) * Lillian Henderson (RSMAS) Warning: Note that N_2O measurements are a Level 3 measurement. The concentrations were measured on the same water samples collected for the Level 1 CFC/SF_6 measurements. The N_2O analysis is still under development. Please contact the PI for any use of these data. Samples for the analysis of dissolved CFC-11, CFC-12, SF_6, and N_2O were collected from approximately 1417 of the Niskin water samples during the expedition. When taken, water samples for tracer analysis were the first samples drawn from the 10-liter bottles. Care was taken to co-ordinate the sampling of the tracers with other samples to minimize the time between the initial opening of each bottle and the completion of sample drawing. In most cases, dissolved oxygen, partial pressure of CO2, dissolved inorganic carbon, and pH samples were collected within several minutes of the initial opening of each bottle. To minimize contact with air, the tracer samples were collected from the Niskin bottle petcock into 250-cc ground glass syringes through plastic 3-way stopcocks. The syringes were stored in the dark in a large ice chest in the laboratory at 3.5º - 6º C until 30-45 minutes before analysis to reduce the degassing and bubble formation in the sample. At that time, they were transferred to a water bath at approximately 35º C to warm the samples prior to analysis in order to increase the stripping efficiency. Concentrations of CFC-11, CFC-12, SF_6, and N_2O in air samples, seawater and gas standards were measured by shipboard electron capture gas chromatography (EC-GC). This system from the University of Washington was located in a portable laboratory on the fantail. Samples were introduced into the EC-GC via a purge and trap system. Approximately 200-ml water samples were purged with nitrogen and the compounds of interest were trapped on a Porapak Q/Carboxen 1000/Molecular Sieve 5A trap cooled by an immersion bath to >-55ºC. During the purging of the sample (6 minutes at 170 ml min-1 flow), the gas stream was stripped of any water vapor via a Nafion trap in line with an ascarite/magnesium perchlorate dessicant tube prior to transfer to the trap. The trap was then isolated and heated by direct resistance to 175ºC. The desorbed contents of the trap were back- flushed and transferred onto the analytical pre-columns. The first precolumn was a 40-cm length of 1/8-in tubing packed with 80/100 mesh Porasil B. This precolumn was used to separate the CFC-11 from the other gases. The second pre-column was 13 cm of 1/8-in tubing packed with 80/100 mesh molecular sieve 5A. This pre-column separated the N_2O from CFC-12 and SF_6. Three analytical columns in three gas chromatographs with electron capture detectors were used in the analysis. CFC-11 was separated from other compounds (e.g. CFC-113 and CCl4) by a column consisting of 36 cm of Porasil B and 150 cm of Carbograph 1AC maintained at 80ºC. CFC-12 and SF_6 were analyzed using a column consisting of 2.33 m of molecular sieve 5A and 1.5 m of Carbograph 1AC maintained at 80ºC. The analytical column for N_2O was 30 cm of molecular sieve 5A in a 120ºC oven. The carrier gas for this column was instrumental grade P-5 gas (95% Ar / 5% CH4) that was directed onto the second precolumn and into the third column for the N_2O analyses. The detectors for the CFC-11, and for CFC-12 and SF_6 analyses were operated at 300ºC. The detector for N_2O was maintained at 320 ºC. The analytical system was calibrated frequently using a standard gas of known gas composition. Gas sample loops of known volume were thoroughly flushed with standard gas and injected into the system. The temperature and pressure were recorded so that the amount of gas injected could be calculated. CFC concentrations in air and seawater samples were determined by fitting their chromatographic peak areas to multi-point calibration curves, generated by injecting multiple sample loops of gas from a working standard (UW WRS 32399) into the analytical instrument. A full range of calibration points were run at the beginning and end of the cruise, as well as during long transits/weather delays when possible. The procedures used to transfer the standard gas to the trap, precolumns, main chromatographic columns and EC detectors were similar to those used for analyzing water samples. Single injections of a fixed volume of standard gas at one atmosphere were run much more frequently (at intervals of 2 hours) to monitor short-term changes in detector sensitivity. Air samples and system blanks (injections of loops of CFC-free gas) were injected and analyzed in a similar manner. The typical analysis time for samples was 740 sec. For atmospheric sampling, an ~100 meter length of 3/8-in OD Dekaron tubing was run from the portable laboratory to the bow of the ship. A flow of air was drawn through this line to the main laboratory using an Air Cadet pump. The air was compressed in the pump, with the downstream pressure held at ~1.5 atm. using a back-pressure regulator. A tee allowed a flow (100 ml min-1) of the compressed air to be directed to the gas sample valves of the CFC/SF_6/N_2O analytical system, while the bulk flow of the air (>7 l min-1) was vented through the back-pressure regulator. Air samples were generally analyzed when the relative wind direction was within 50 degrees of the bow of the ship to reduce the possibility of shipboard contamination. The pump was run for approximately 30 minutes prior to analysis to insure that the air inlet lines and pump were thoroughly flushed. The average atmospheric concentrations determined during the cruise (from sets of 3 or 4 measurements analyzed when possible) were 221.9 +/- 1.8 parts per trillion (ppt) for CFC-11 (n=27), 496.6+/- 1.8 ppt for CFC-12 (N=40), 10.8 +/- 0.2 ppt for SF_6 (N=15), and 332.9 +/- 2.0 parts per billion for N_2O (N=19). Concentrations of the CFCs in air, seawater samples and gas standards are reported relative to the SIO98 calibration scale [Prinn00]. Concentrations in air and standard gas are reported in units of mole fraction in dry gas, and are typically in the parts per trillion (ppt) range for CFCs and SF_6 and parts per billion (ppb) for N_2O. Dissolved CFC concentrations are given in units of picomoles per kilogram seawater (pmol/kg), SF_6 in femtomoles per kilogram seawater (fmol/kg), and N_2O in nanomoles per kilogram seawater (nmol/kg). Estimated limit of detection is 1 fmol/kg for CFC-11, 1 fmol/kg for CFC-12 and 0.01 fmol/kg for SF_6. The efficiency of the purging process was evaluated by re-stripping water samples and comparing the residual concentrations to initial values. These re-strip values were less than 1% for CFC-11 and essentially zero for CFC-12 and SF_6. Based on the re-strips of numerous samples where the stripper blank was low and relatively constant, the mean values for N_2O were approximately 5-10% during the cruise. On this expedition, based on the analysis of 40 duplicate samples (i.e. two syringe samples collected from the same Niskin), we estimate precisions (1 standard deviation) of 0.65% or 0.0012 pmol/kg (whichever is greater) for dissolved CFC-11, 0.36% or 0.00058 pmol/kg for CFC-12 measurements, 0.017 fmol/kg or 1.98% for SF_6, and 0.67% or 0.096 nmol/kg for N_2O. Analytical Difficulties/Acknowledgements ---------------------------------------- During A20, two immersion coolers failed – the first lost coolant through a leak during transport to the start of A20; the second had its low-stage compressor fail during the transit after the completion of the measurement program of A20. Without an immersion cooler for the trapping process, we would have only been able to measure CFC-12 for A22. Thanks to the efforts of Dana Greeley, Eric Wisegarver, the shipping department at NOAA-PMEL and the tracer measurement lab at NOAA-PMEL, a spare working immersion cooler was located, tested, and shipped to St. Thomas in advance of the departure for A22. We were only able to make high-precision measurements during this cruise due to the efforts, above and beyond, of the people listed above. These individuals deserve the credit for the quality of the reported data. [Prinn00] Prinn, R. G., Weiss, R.F., Fraser, P.J., Simmonds, P.G., Cunnold, D.M., Alyea, F.N., O’Doherty, S., Salameh, P., Miller, B.R., Huang, J., Wang, R.H.J., Hartley, D.E., Harth, C., Steele, L.P., Sturrock, G., Midgley, P.M., McCulloch, A., 2000. A history of chemically and radiatively important gases in air deduced from ALE/GAGE/AGAGE. Journal of Geophysical Research, 105, 17,751-17,792 Dissolved Organic Carbon and Total Dissolved Nitrogen ===================================================== PI * 3. Carlson (UCSB) Technician * Chance English (UCSB) Analysts * Keri Opalk * Elisa Halewood Support NSF Project Goals ------------- The goal of the DOM project is to evaluate dissolved organic carbon (DOC) and total dissolved nitrogen (TDN) concentrations along the A22 meridional transect occupied between April and May 2021. Sampling -------- DOC profiles were taken at every other station from every depth sampled by the CTD (45 stations) DOC samples were passed through an inline filter holding a combusted GF/F filter attached directly to the Niskin for samples in the top 500 m of each cast. This was done to eliminate particles larger than 0.6 µm from the sample. Samples from deeper depths were not filtered. Previous work has demonstrated that there is no resolvable difference between filtered and unfiltered samples in waters below the upper 500 m at the µmol kg-1 resolution. All samples were rinsed 3 times with about 5 mL of seawater and collected into combusted 40 mL glass EPA vials. Samples were fixed with 75 uL of 4N Hydrochloric acid and stored at room temperature on board. Samples were shipped back to UCSB for analysis via high temperature combustion on Shimadzu TOC-V or TOC L analyzers. Sample Vials were prepared for this cruise by soaking in 10% Hydrochloric acid, followed by a 3 times rinse with DI water. The vials were then combusted at 450ºC for 4 hours to remove any organic matter. Vial caps were cleaned by soaking in DI water overnight, followed by a 3 times rinse with DI water and left out to dry. Sampling goals for this cruise were to continue high resolution, long term monitoring of DOC distribution throughout the water column, in order to help better understand biogeochemical cycling in global oceans. Standard Operating Procedure for DOC analyses – Carlson Lab UCSB ---------------------------------------------------------------- DOC samples will be analyzed via high temperature combustion using a Shimadzu TOC-V or Shimadzu TOC-L at an in shore based laboratory at the University of California, Santa Barbara. The operating conditions of the Shimadzu TOC-V have been slightly modified from the manufacturer’s model system. The condensation coil has been removed and the headspace of an internal water trap was reduced to minimize the system’s dead space. The combustion tube contains 0.5 cm Pt pillows placed on top of Pt alumina beads to improve peak shape and to reduce alteration of combustion matrix throughout the run. CO_2 free carrier gas is produced with a Whatman® gas generator [Carlson2010]. Samples are drawn into a 5 ml injection syringe and acidified with 2M HCL (1.5%) and sparged for 1.5 minutes with CO_2 free gas. Three to five replicate 100 µl of sample are injected into a combustion tube heated to 680º. The resulting gas stream is passed though several water and halide traps, including an added magnesium perchlorate trap. The CO_2 in the carrier gas is analyzed with a non-dispersive infrared detector and the resulting peak area is integrated with Shimadzu chromatographic software. Injections continue until the at least three injections meet the specified range of a SD of 0.1 area counts, CV :math:>>`<>`<0.8µm). During A22 samples were filtered sequentially through a 0.8 and 0.2 µm polycarbonate filter which were then stored in 2ml sterile cryovials at -20ºC until further analysis. Samples from A22 were stored on board until being shipped back to an in-shore laboratory at the University of California, Santa Barbara. The method uses the spectrophotometric absorption of the INT-f at 485 nm to determine the rate at which the insoluble crystals are formed inside the cell membranes. Absorbance of each sample will be determined by incubating the filters in 1 mL of 1-propanol, followed by sonication and centrifugation. The concentration of the INT-f in solution is calculated from its absorbance by applying a standard curve previously determined using twelve different concentrations of stock INT-f dissolved in pure 1-propanol. Stations sampled ^^^^^^^^^^^^^^^^ +------------------+------------------+------------------+------------------+------------------+------------------+ | 2 | 10 | 14 | 18 | 20 | 22 | +------------------+------------------+------------------+------------------+------------------+------------------+ | 32 | 34 | 38 | 41 | 42 | 44 | +------------------+------------------+------------------+------------------+------------------+------------------+ | 48 | 50 | 52 | 54 | 58 | 62 | +------------------+------------------+------------------+------------------+------------------+------------------+ | 64 | 68 | 70 | 72 | 73 | 74 | +------------------+------------------+------------------+------------------+------------------+------------------+ | 76 | 78 | 80 | 84 | 86 | 88 | +------------------+------------------+------------------+------------------+------------------+------------------+ [DelGiorgio2005] Del Giorgio, P. A., & Williams, P. J. leB (Eds.). (2005). Respiration in aquatic ecosystems. Oxford University Press. [García-Martín2019] García-Martín, E. E., Aranguren-Gassis, M., Karl, D. M., Martínez-García, S., Robinson, C., Serret, P., & Teira, E. (2019). Validation of the in vivo Iodo-Nitro-Tetrazolium (INT) Salt Reduction Method as a Proxy for Plankton Respiration. Frontiers in Marine Science, 6, 220. https://doi.org/10.3389/fmars.2019.00220 [Martínez-García2009] Martínez-García, S., Fernández, E., Aranguren- Gassis, M., & Teira, E. (2009). In vivo electron transport system activity: A method to estimate respiration in natural marine microbial planktonic communities: Estimating in vivo ETS activity rates. Limnology and Oceanography: Methods, 7(6), 459–469. https://doi.org/10.4319/lom.2009.7.459 [Packard1996] Packard, T. T., Berdalet, E., Blasco, D., Roy, S. O., St-Amand, L., Lagacé, B., Lee, K., & Gagnó, J.-P. (1996). Oxygen consumption in the marine bacterium Pseudomonas nautica predicted from ETS activity and bisubstrate enzyme kinetics. Journal of Plankton Research, 18(10), 1819–1835. https://doi.org/10.1093/plankt/18.10.1819 [Robinson2019] Robinson, C. (2019). Microbial Respiration, the Engine of Ocean Deoxygenation. Frontiers in Marine Science, 5, 533. https://doi.org/10.3389/fmars.2018.00533 Oxygen Stable Isotope Record (\delta^18O) ========================================= PI * Kaustubh Thirumalai Cruise Participant * Maya Prabhakar Intent ------ The creation of a seawater \delta^18O record for studying recent and modern planktic foraminiferal \delta^18O in the N. Atlantic to reconstruct past climate and create modern calibrations. Sampling -------- At least two 5mL samples of water were collected at every station. Every station was sampled at 5m (surface, mixed layer) and at the chlorophyll maximum, which varies at each station. Opportunistic third and fourth samples were taken when Stephanie O’Daly’s underwater vision profiler photographs showed foraminifera at those depths at nearby stations. Samples were taken at the end of sampling by running vials under a weak stream from the bottle spigot until air bubbles were absent. The sample was then capped and inverted to check for air bubbles. Some samples were lost early in the cruise due to inexperience sampling from the bottles, resulting in air bubbles, causing the additional step of an inversion to be added. Samples were then parafilmed to prevent atmosphere and sample interaction. If, upon inspection, samples were deemed improperly parafilmed, additional parafilm was used to ensure a seal. Samples were labeled and stored in a temperature-controlled room. Depth, longitude, latitude, bottle number, date, sampler, and notes were recorded during sampling. Processing ---------- Samples will be processed on a Picarro isotopic water analyzer at the St. Petersburg Coastal and Marine Science Center. Methods and data will be published within the next three years. Acknowledgements ---------------- I would like to acknowledge the help of another student, Holly Olivarez, in sampling when I was unable. Student Statements ================== U.S. GO-SHIP thanks all of the students who participated on the cruise for their important contribution to collection of this essential global ocean data set, used as the benchmark for accuracy of all other deep ocean observing systems. The training opportunity for students and leadership is an important part of US GO-SHIP’s mission. We are committed to do so in a fair, cooperative and professional environment, ensuring an inclusive, safe and productive climate at sea. We thank the students for their honest reflections on their experiences that are included in this section. We have reached out to those who expressed concerns and are taking issues raised seriously, by working to address and prevent these issues from occurring in the future. We also thank them for their feedback in the anonymous post- cruise survey, which we are using to continue to improve our program. This will include ongoing education for all members of our community to create a more inclusive environment. Lillian Henderson ----------------- As primarily a marine organic geochemist, the research I do on a daily basis involves intensive lab work and wet chemistry in order to isolate individual compounds for stable carbon and nitrogen isotope analysis. Because of the time required to prepare each sample, I typically work with relatively small datasets/sample sizes. In contrast, the CFC work I was able to do on the GO-SHIP A22 hydrographic cruise involves very little sample preparation, allowing for much larger collections of data. These larger datasets provide better understanding of the global ocean circulation patterns. Being a part of this cruise provided me an opportunity to learn a new sampling method and analytical technique that I would not have been exposed to otherwise. I learned about the analytical system used to measure CFC/SF6/N2O concentrations and how these data are used. I had a great time getting to know everyone, and I hope to work on another GO-SHIP cruise in the future! Holly Olivarez -------------- *Environmental Studies Program and the Institute of Arctic and Alpine Research (INSTAAR)* As a graduate student who statistically models the variability of air- sea CO_2 flux using in situ surface ocean p|CO2| observations, I am very grateful for the experience and perspective I gained from being part of the A22 hydrographic research cruise. From the science to the people on the ship, being here has helped me grow as a human and as a scientist. Even though I have worked in an observational environment before, it was not related to oceanography. The ocean knows no borders and sharing passion and curiosity for this critical system on Earth with fellow scientists and ship crewmates was priceless. I learned of the many ways one small, overlooked detail (either due to inexperience or fatigue) can disrupt or invalidate a rosette full of freshly collected seawater, or how moving a cast time to accommodate dinner for samplers impacts the ship crew, too. I learned about folks who care so deeply about “good” data that they devote their career to the science of taking accurate and precise measurements. I also learned that those who have been at sea for much of their career, either as a scientist or as a ship crewmate, can teach me more than I’ve learned in any classroom or textbook. I suppose the real challenge then becomes finding the intersection between those who teach in a classroom, who lay the groundwork for future real-world application, and those who teach us in the moment as we are doing the actual science. My PhD research is based on the simulated Earth system but grounded in real world observations. Without observations, scientists’ simulations of the Earth system would be purely theoretical. This experience has given me the perspective and recognition of real-world observations as the foundation of what I do. This is something I will not forget as I forge ahead in my career. Thank you to all involved in the GO-SHIP project and thank you for the opportunity to be a part of it. Maya Prabhakar -------------- As a paleoclimate student with a background in geology, moving my fieldwork from land to sea has been a sizable shift. The Thompson, and GO-SHIP, is a great introduction to ocean research. I attended as a CTD watch-stander to better understand how CTD data is collected since I use it often in my research. I have thoroughly met my goal. We, the attending students, have prepped casts for deployment and for sampling, giving us a good understanding of the mechanical workings of the rosette. Monitoring casts has allowed us to see the change in station oceanography in real time and provided good conversations. The limitations of the subsequent data and uncertainties are better categorized in my head when thinking about the datasets I use from GO- SHIP and similar projects. Our graduate curriculum is light in physical oceanography, so being able to ask questions consistently for a month provided a useful learning experience. I am primarily interested in noting the data from the Gulf Stream because I focus on the Arctic and the Fram Strait, which are heavily influenced by the Gulf Stream. This cruise has brought about several questions related to my field of study which I plan to explore when I am. I have been consistently fortunate to work for, and with, numerous women and racial minorities during school. This is a strong contrast to the ship. I am still fortunate to be working under two amazing women acting as chief scientists during this leg and I have loved being able to ask questions and discuss science with them and the other women on board, but I have run into multiple occasions during this leg where I have been patronized consistently by a handful of people, often on topics I have training and experience in. It has reminded me to be grateful as a racial minority and a woman to work in the labs I do and collaborate with the people I currently work with. It is an unfortunate epidemic in the whole of science, but I note it as a distinct failure of the GO-SHIP cruise. Being able to actively learn and bring a background of geology to the cruise has been a lot of fun and a welcome change from the zoom learning of a covid-19 world. I have gained numerous skills and insights that will help me navigate future fieldwork and create new discussions in my lab. I look forward to publishing the geochemical data from this cruise. Victoria Schoenwald ------------------- The A22 leg of this year’s GO-SHIP cruise was my first glance into what observational oceanography is all about. I participated as a CTD Watch Stander on the night shift for 30 days which involved long hours of watching the CTD rise and fall into the water while monitoring screens taking real time data from temperature to voltage spikes from the UVP. Being a part of a modelling lab as a graduate student at the UM RSMAS, I would not have had the opportunity to go to sea if not for programs like GO-SHIP. I am grateful that all of the scientists on board were happy to allow new students to become part of their research. When I first decided to pursue a career in oceanography, I was excited about discovering the way the ocean, atmosphere, and land interreact with one another. I later realized that my interests aligned well with global climate modelling and field work would not be part of my Ph.D. experience. From the start I knew that I would want to get back into field work some way or another so when I discovered there were openings to come on the A22 leg I was very excited. Back in Miami I was researching sea level rise and coastal flooding using global data sets and climate models. Being on the CTD team therefore allowed me to see where some of my data is coming from and how the ocean off of the East Coast of the U.S. has been changing over the years. Besides the knowledge I learned from the science team one of the most rewarding parts of the cruise was getting to know the crew. I enjoyed hearing their stories about travelling, life at sea and gained perspective on careers that I previously knew nothing about. Getting to know more people who love the ocean as much as I do has made this month an unforgettable one. This experience has reminded me why I chose to research the ocean in the first place, and I hope to have the chance to participate in more research cruises in the future. Ali Siddiqui ------------ To whoever reads this in 10 years Hi there! I was a CTD watchstander and the LADCP operator for the A22 2021 GO- SHIP cruise. If you’re a student reading this, wondering what a watchstander or an LADCP operator experiences in a GO-SHIP cruise, I might not be able to do justice in this short statement. If you’re a PI reading this, and wondering if your students should take part in a GO-SHIP cruise, this statement would only offer a fleeting peak into the experiences of potential students. If you’re just someone browsing through student statements, I hope this one offers you something of value about the lives of GO-SHIP participants. I guess the only person who really needs to read this is Mike Kovatch who’s wonderful job gives him the pleasure to make cruise reports which contain the tired musings of departing students. So, let me be terse. As someone whose research involves modeling the ocean using computers, it’s very easy for me to forget what the real ocean looks like. The ocean exists in the virtual world with smooth data and exact floating points accurate to the precision of the computer. What the CTD watchstanding taught me was how the ocean really looks like. In person. Or in water ? It taught me the importance of taking accurate, reliable and long-term measurements of the ocean using the CTD. It is very easy to sit in a lab and complain about missing data in the ocean. What this cruise has taught me is the value of recording data during each CTD cast and the amount of hard work and labor that goes into procuring a single vertical profile in the deep ocean. Undoubtedly, I’m going to be a better oceanographer after this cruise, or atleast a more informed one. As for the LADCP, even though I had read up about the theory of the Acoustic Doppler and its functionality, it was an extremely enlightening experience to operate the instrument on my own. Admittedly, I was very nervous in the beginning but things got better as we performed regular deployments. Processing and understanding the ADCP data was another trick of the trade that I got to learn as we made our way from the Caribbean to the familiar shores of Woods Hole. Hopefully, I will have more opportunities in the future to operate the LADCP. There are a few of lessons that I will take away from my experience. I hope when someone reads this, they would find them helpful too. The first is about the importance of the ship crew. Without them, no science would ever be done. On the R/V Thompson, the crew was the star of the show in my eyes. They would help us with deployments, carry out maintenance on the ship, feed us, navigate us, and most importantly give us a glimpse into the lives of people who spend half their lives on the sea. If any person in a position of leadership is reading this, I want to acknowledge how important the crew of the R/V TGT was to us and commend them on a brilliant job they did to help us do our science. Another lesson was about the importance of staying patient on the ship. Taking measurements in the sea can get monotonic after a while, and people tend to slack off and become impatient with the process. I realized how important it was to carefully go through each and every step in our deployments, right from preparing and keeping track of log sheets to preparing the rosette for each cast, all the way up to firing bottles at the right depth and eventual recovery and sampling. Even though we get trained in all these exercises, it is interesting to see how much one can learn about an activity each time you repeat it. This brings me to the final lesson worth typing in this statement, which is that of mental well being at sea. The ship is a small space to be in for a month with a bunch of people who you’ve never met. It is very easy to get cranky around mid-way through the cruise. However, it really helps if you have something to occupy yourself with on your time off. Reading books, playing chess or catan and even darts, personal writing, admiring the ocean and the stars on the hammock at the bow, were some of the things that helped me keep myself cheerful. Obviously, this was on top of making friends with some really amazing people on the ship. If that doesn’t give much glimpse into the mind of a watchstander, then maybe the knowledge that most of us were even dreaming of the CTD and muttering, “Roger that, we are ready to deploy”, should tell you all about the experience. With hope, Ali Siddiqui