Data Description |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Data Identifiers |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Time Co-ordinates(UT) |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Spatial Co-ordinates | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Parameters |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
No Problem Report Found in the Database
Data users should note that oxygen saturation values in the range of 100-120% were recorded in the near-surface water for the majority of casts on this cruise.
You must always use the following attribution statement to acknowledge the source of the information: "Contains data supplied by Natural Environment Research Council."
The SBE 43 is a dissolved oxygen sensor designed for marine applications. It incorporates a high-performance Clark polarographic membrane with a pump that continuously plumbs water through it, preventing algal growth and the development of anoxic conditions when the sensor is taking measurements.
Two configurations are available: SBE 43 produces a voltage output and can be incorporated with any Sea-Bird CTD that accepts input from a 0-5 volt auxiliary sensor, while the SBE 43F produces a frequency output and can be integrated with an SBE 52-MP (Moored Profiler CTD) or used for OEM applications. The specifications below are common to both.
Housing | Plastic or titanium |
Membrane | 0.5 mil- fast response, typical for profile applications 1 mil- slower response, typical for moored applications |
Depth rating | 600 m (plastic) or 7000 m (titanium) 10500 m titanium housing available on request |
Measurement range | 120% of surface saturation |
Initial accuracy | 2% of saturation |
Typical stability | 0.5% per 1000 h |
Further details can be found in the manufacturer's specification sheet.
The primary CTD system used on cruise JC086 was the Sea-Bird 911 plus. This was mounted on a stainless steel rosette frame, equipped with 24 10-litre Niskin bottles. The CTD was fitted with the following scientific sensors:
Sensor Unit | Model | Serial Number | Full Specification | Last calibration date (YYYY-MM-DD) | Comments |
---|---|---|---|---|---|
CTD underwater unit | SBE 9plus | 09P-0943 | SBE 9plus | - | - |
Temperature sensor | SBE 3P | 03P-2674 | SBE 03P | 2012-07-06 | Primary sensor |
Temperature sensor | SBE 3P | 03P-4782 | SBE 03P | 2012-07-06 | Secondary sensor - this sensor is the preferred data stream |
Conductivity sensor | SBE 4 | 04C-2231 | SBE 04C | 2012-07-06 | Primary sensor |
Conductivity sensor | SBE 4 | 04C-2450 | SBE 04C | 2012-05-08 | Secondary sensor - this sensor is the preferred data stream |
Pressure sensor | SBE 9plus digiquartz | 110557 | - | 2012-05-29 | - |
Dissolved oxygen | SBE 43 | 43-2055 | SBE 43 | 2012-06-27 | - |
Benthos altimeter | - | 6196.112522 | - | 2006-03-13 | - |
Turbidity meter | WET Labs ECO-BBRTD | 168 | - | 2012-09-24 | - |
Chlorophyll fluorometer | Chelsea Instruments AQUAtracka MKIII | 088195 | AQUAtracka MKIII | 2012-08-21 | - |
Transmissometer | Chelsea Instruments Alphatracka MKII | 09-7107-001 | Alphatracka MKII | 2012-06-11 | - |
The salinity samples from the CTD were analysed during the cruise using a Guildline Autosal model 8400B. Dissolved oxygen concentrations were determined using a Winkler titration technique.
The SBE 911 and SBE 917 series of conductivity-temperature-depth (CTD) units are used to collect hydrographic profiles, including temperature, conductivity and pressure as standard. Each profiler consists of an underwater unit and deck unit or SEARAM. Auxiliary sensors, such as fluorometers, dissolved oxygen sensors and transmissometers, and carousel water samplers are commonly added to the underwater unit.
The CTD underwater unit (SBE 9 or SBE 9 plus) comprises a protective cage (usually with a carousel water sampler), including a main pressure housing containing power supplies, acquisition electronics, telemetry circuitry, and a suite of modular sensors. The original SBE 9 incorporated Sea-Bird's standard modular SBE 3 temperature sensor and SBE 4 conductivity sensor, and a Paroscientific Digiquartz pressure sensor. The conductivity cell was connected to a pump-fed plastic tubing circuit that could include auxiliary sensors. Each SBE 9 unit was custom built to individual specification. The SBE 9 was replaced in 1997 by an off-the-shelf version, termed the SBE 9 plus, that incorporated the SBE 3 plus (or SBE 3P) temperature sensor, SBE 4C conductivity sensor and a Paroscientific Digiquartz pressure sensor. Sensors could be connected to a pump-fed plastic tubing circuit or stand-alone.
The conductivity, temperature, and pressure sensors supplied with Sea-Bird CTD systems have outputs in the form of variable frequencies, which are measured using high-speed parallel counters. The resulting count totals are converted to numeric representations of the original frequencies, which bear a direct relationship to temperature, conductivity or pressure. Sampling frequencies for these sensors are typically set at 24 Hz.
The temperature sensing element is a glass-coated thermistor bead, pressure-protected inside a stainless steel tube, while the conductivity sensing element is a cylindrical, flow-through, borosilicate glass cell with three internal platinum electrodes. Thermistor resistance or conductivity cell resistance, respectively, is the controlling element in an optimized Wien Bridge oscillator circuit, which produces a frequency output that can be converted to a temperature or conductivity reading. These sensors are available with depth ratings of 6800 m (aluminium housing) or 10500 m (titanium housing). The Paroscientific Digiquartz pressure sensor comprises a quartz crystal resonator that responds to pressure-induced stress, and temperature is measured for thermal compensation of the calculated pressure.
Optional sensors for dissolved oxygen, pH, light transmission, fluorescence and others do not require the very high levels of resolution needed in the primary CTD channels, nor do these sensors generally offer variable frequency outputs. Accordingly, signals from the auxiliary sensors are acquired using a conventional voltage-input multiplexed A/D converter (optional). Some Sea-Bird CTDs use a strain gauge pressure sensor (Senso-Metrics) in which case their pressure output data is in the same form as that from the auxiliary sensors as described above.
Each underwater unit is connected to a power supply and data logging system: the SBE 11 (or SBE 11 plus) deck unit allows real-time interfacing between the deck and the underwater unit via a conductive wire, while the submersible SBE 17 (or SBE 17 plus) SEARAM plugs directly into the underwater unit and data are downloaded on recovery of the CTD. The combination of SBE 9 and SBE 17 or SBE 11 are termed SBE 917 or SBE 911, respectively, while the combinations of SBE 9 plus and SBE 17 plus or SBE 11 plus are termed SBE 917 plus or SBE 911 plus.
Specifications for the SBE 9 plus underwater unit are listed below:
Parameter | Range | Initial accuracy | Resolution at 24 Hz | Response time |
---|---|---|---|---|
Temperature | -5 to 35°C | 0.001°C | 0.0002°C | 0.065 sec |
Conductivity | 0 to 7 S m-1 | 0.0003 S m-1 | 0.00004 S m-1 | 0.065 sec (pumped) |
Pressure | 0 to full scale (1400, 2000, 4200, 6800 or 10500 m) | 0.015% of full scale | 0.001% of full scale | 0.015 sec |
Further details can be found in the manufacturer's specification sheet.
The Chelsea Technologies Group Aquatracka MKIII is a logarithmic response fluorometer. Filters are available to enable the instrument to measure chlorophyll, rhodamine, fluorescein and turbidity.
It uses a pulsed (5.5 Hz) xenon light source discharging along two signal paths to eliminate variations in the flashlamp intensity. The reference path measures the intensity of the light source whilst the signal path measures the intensity of the light emitted from the specimen under test. The reference signal and the emitted light signals are then applied to a ratiometric circuit. In this circuit, the ratio of returned signal to reference signal is computed and scaled logarithmically to achieve a wide dynamic range. The logarithmic conversion accuracy is maintained at better than one percent of the reading over the full output range of the instrument.
Two variants of the instrument are available, both manufactured in titanium, capable of operating in depths from shallow water down to 2000 m and 6000 m respectively. The optical characteristics of the instrument in its different detection modes are visible below:
Excitation | Chlorophyll a | Rhodamine | Fluorescein | Turbidity |
---|---|---|---|---|
Wavelength (nm) | 430 | 500 | 485 | 440* |
Bandwidth (nm) | 105 | 70 | 22 | 80* |
Emission | Chlorophyll a | Rhodamine | Fluorescein | Turbidity |
Wavelength (nm) | 685 | 590 | 530 | 440* |
Bandwidth (nm) | 30 | 45 | 30 | 80* |
* The wavelengths for the turbidity filters are customer selectable but must be in the range 400 to 700 nm. The same wavelength is used in the excitation path and the emission path.
The instrument measures chlorophyll a, rhodamine and fluorescein with a concentration range of 0.01 µg l-1 to 100 µg l-1. The concentration range for turbidity is 0.01 to 100 FTU (other wavelengths are available on request).
The instrument accuracy is ± 0.02 µg l-1 (or ± 3% of the reading, whichever is greater) for chlorophyll a, rhodamine and fluorescein. The accuracy for turbidity, over a 0 - 10 FTU range, is ± 0.02 FTU (or ± 3% of the reading, whichever is greater).
Further details are available from the Aquatracka MKIII specification sheet.
The Chelsea Technologies Group ALPHAtracka (the Mark I) and its successor, the ALPHAtracka II (the Mark II), are both accurate (< 0.3 % fullscale) transmissometers that measure the beam attenuation coefficient at 660 nm. Green (565 nm), yellow (590 nm) and blue (470 nm) wavelength variants are available on special order.
The instrument consists of a Transmitter/Reference Assembly and a Detector Assembly aligned and spaced apart by an open support frame. The housing and frame are both manufactured in titanium and are pressure rated to 6000 m depth.
The Transmitter/Reference housing is sealed by an end cap. Inside the housing an LED light source emits a collimated beam through a sealed window. The Detector housing is also sealed by an end cap. A signal photodiode is placed behind a sealed window to receive the collimated beam from the Transmitter.
The primary difference between the ALPHAtracka and ALPHAtracka II is that the Alphatracka II is implemented with surface-mount technology; this has enabled a much smaller diameter pressure housing to be used while retaining exactly the same optical train as in the Mark I. Data from the Mark II version are thus fully compatible with that already obtained with the Mark I. The performance of the Mark II is further enhanced by two electronic developments from Chelsea Technologies Group - firstly, all items are locked in a signal nulling loop of near infinite gain and, secondly, the signal output linearity is inherently defined by digital circuitry only.
Among other advantages noted above, these features ensure that the optical intensity of the Mark II, indicated by the output voltage, is accurately represented by a straight line interpolation between a reading near full-scale under known conditions and a zero reading when blanked off.
For optimum measurements in a wide range of environmental conditions, the Mark I and Mark II are available in 5 cm, 10 cm and 25 cm path length versions. Output is default factory set to 2.5 volts but can be adjusted to 5 volts on request.
Further details about the Mark II instrument are available from the Chelsea Technologies Group ALPHAtrackaII specification sheet.
An optical scattering sensor that measures scattering at 117°. This angle was determined as a minimum convergence point for variations in the volume scattering function induced by suspended materials and water. The measured signal is less determined by the type and size of the materials in the water and is more directly correlated to their concentration.
Several versions are available, with minor differences in their specifications:
Wavelength | 471, 532, 660 nm |
Sensitivity (m-1 sr-1) | 1.2 x 10-5 at 470 nm 7.7 x 10-6 at 532 nm 3.8 x 10-6 at 660 nm |
Typical range | ~0.0024 to 5 m-1 |
Linearity | 99% R2 |
Sample rate | up to 8Hz |
Temperature range | 0 to 30°C |
Depth rating | 600 m (standard) 6000 m (deep) |
Further details can be found in the manufacturer's specification sheet.
The following information contains extracts from the JC086 cruise report.
A total of 81 CTD casts were performed during the cruise which sailed from and back to Govan on the west coast of Scotland, incorporating the Extended Ellett Line and Wyville Thomson Ridge area. All casts deployed during the cruise were housed in a stainless steel frame equipped with dual temperature and conductivity sensors. The CTD sensors were located within and near the bottom of the rosette frame which held 24 10-litre Niskin water sampling bottles.
Raw CTD data were transferred from the Sea-Bird deck unit to a LINUX machine via Sea-Bird software. The binary files are converted using Sea-Bird processing software. Physical units were calculated from the frequency data using the manufacturer's calibration routines and the data converted to ASCII format. The ASCII files were converted to MSTAR format and MEXEC programs run to process the data which included reducing the frequency of the data from 24Hz to 1Hz, calibrating the data, and averaging the downcast to a 2db pressure grid. A calibration was produced by merging the salinity sample data with the CTD data. Details of the MEXEC programs used and further details of the processing performed can be found in Griffiths et al. (2013).
Throughout the cruise the CTD was sampled for salinity measurements in order to calibrate the conductivity sensors. Salinity was measured using a Guildline Autosal 8400B (#60839) in a temperature controlled room with the bath temperature set at 21°C and the ambient temperature set at approximately 20°C. All CTD data used for calibration purposes is sourced from the bottle files created by the Sea-Bird software. The autosal was standardised at the start of every run and a standard seawater analysed at the end of every crate. Each crate contained 24 bottles.
The primary and secondary conductivity sensors were treated separately, where the bottle salinity data was used to calculate the bottle conductivity. This was then compared with the CTD conductivity for calibration purposes. Both sensors portrayed a change in calibration over time, with an apparent drift around CTD casts 16-19. There was, however, a 3 day break between cast 16 and cast 17 which is the likely cause of this change, so the stations were placed into 2 groups for conductivity calibration purposes (casts 1-16 and casts 17-81). The secondary sensor has been specified as the preferred data stream for this dataset, where the mean of all salinity residuals for this sensor was 0.0109, and the standard deviation 0.0671. Excluding outliers (defined as +/- 1 standard deviation from the mean), the mean of salinity residuals is 0.0004 and the standard deviation 0.0049.
Bottle oxygen values were used to calibrate the CTD oxygen sensor. Firstly, the relationship between the bottle oxygen and the CTD oxygen was examined. Bottle sample units were converted to umol/kg using the calibrated CTD salinity.
Oxygen was sampled by both the National Oceanography Centre (NOC) and the Scottish Association for Marine Science (SAMS) chemists, but was initially examined separately as part of inter-group comparison during the cruise. The 2 groups samples taken from different niskin bottles from the same casts, were often, but not always, fired at the same depths. The NOC group sampled more bottles than the SAMS group. Although there was a small offset between the NOC and SAMS oxygen samples, it was very difficult to determine which possessed higher accuracy, and so for the calibration of the CTD oxygen sensor all available oxygen bottle samples were used.
After calibrations had been applied the mean of all oxygen residuals was 0.2 +/- 7.8 umol/kg, and when excluding outliers the mean was 1.0 +/- 5.1 umol/kg.
It was decided that the secondary sensor was the preferred data stream for all parameters measured throughout the JC086 cruise.
Griffiths C. R. et al., (2013). RRS James Cook Cruise JC086, 06 May 2013 - 26 May 2013. Govan to Govan, Scotland - the Extended Ellett Line. Scottish Association for Marine Science. (Scottish Marine Institute, Oban).
Available - Cruise JC086 Internal Report
Data arrived at BODC in a total of 81 MSTAR files representing the CTD casts conducted during cruise JC086. The data contained in the files are the downcast data averaged to a 2db pressure grid including temperature, salinity and dissolved oxygen channels processed to WOCE standards alongside concurrent fluorometer, transmissometer and turbidity data.
The casts were reformatted to BODC's internal NetCDF format. The following table shows the mapping of variables within the MSTAR files to appropriate BODC parameter codes:
Originator's Variable | Units | Description | BODC Parameter Code | Units | Comments |
---|---|---|---|---|---|
press | dbar | Pressure exerted by the water column | PRESPR01 | dbar | Manufacturer's calibration applied. |
temp | °C | Temperature of the water column by CTD (secondary sensor) | TEMPST02 | °C | The secondary sensor is the preferred data stream. |
temp1 | °C | Temperature of the water column by CTD (primary sensor) | TEMPST01 | °C | - |
temp2 | °C | Temperature of the water column by CTD (secondary sensor) | - | - | Not transferred. temp and temp2 contain the same data values so only temp was transferred. |
cond | mS/cm | Electrical conductivity of the water column by CTD (secondary sensor) | CNDCST02 | S/m | /10. Calibrated by Originator with discrete salinity samples from CTD bottles. The secondary sensor is the preferred data stream. |
cond1 | mS/cm | Electrical conductivity of the water column by CTD (primary sensor) | CNDCST01 | S/m | - |
cond2 | mS/cm | Electrical conductivity of the water column by CTD (secondary sensor) | - | - | Not transferred. cond and cond2 contain the same data values so only cond was transferred. |
psal | - | Practical salinity of the water column by CTD (secondary sensor) | PSALST02 | - | Calculated by Originator using calibrated conductivity. The secondary sensor is the preferred data stream. |
psal1 | - | Practical salinity of the water column by CTD (primary sensor) | PSALST01 | - | Calculated by Originator using calibrated conductivity. |
psal2 | - | Practical salinity of the water column by CTD (seconday sensor) | - | - | Not transferred. psal and psal2 contain the same data values so only psal was transferred. |
oxygen | µmol/kg | Concentration of oxygen per unit volume of the water column | DOXYZZ01 | µmol/l | Calibrated by Originator using discrete water samples from CTD bottles. Unit conversion automatically applied during transfer. |
transmittance | % | Transmittance per 25 cm length of the water column by transmissometer | POPTDR01 | % | - |
fluor | ug/l | Concentration of chlorophyll-a per unit volume of the water column | CPHLPR01 | mg/m3 | No unit conversion required as ug/l is the same as mg/m3. |
turbidity | m-1/sr | Attenuance due to backscatter (660 nm wavelength at 117 degree incidence) by the water body | BB117R01 | m-1/sr | - |
depth | m | Depth below surface converted from pressure using UNESCO algorithm | DEPHPR01 | m | - |
altimeter | m | Height above bed from CTD | - | - | Not transferred. |
time | s | Time in seconds since the origin defined in the metadata field data_time_origin | - | - | Not transferred. |
potemp | °C | Potential temperature of the water column (secondary sensor) | - | - | Not transferred. |
potemp1 | °C | Potential temperature of the water column (primary sensor) | - | - | Not transferred. |
potemp2 | °C | Potential temperature of the water column (secondary sensor) | - | - | Not transferred. |
press_temp | °C | Temperature of the pressure sensor | - | - | Not transferred. |
The reformatted data were visualised using the in-house EDSERPLO software. Suspect data were marked by adding an appropriate quality control flag, and missing data marked by both setting the data to an appropriate value and setting the quality control flag.
Detailed metadata and documentation were compiled and linked to the data.
BODC screen both the series header qualifying information and the parameter values in the data cycles themselves.
Header information is inspected for:
Documents are written by BODC highlighting irregularities which cannot be resolved.
Data cycles are inspected using time or depth series plots of all parameters. Currents are additionally inspected using vector scatter plots and time series plots of North and East velocity components. These presentations undergo intrinsic and extrinsic screening to detect infeasible values within the data cycles themselves and inconsistencies as seen when comparing characteristics of adjacent data sets displaced with respect to depth, position or time. Values suspected of being of non-oceanographic origin may be tagged with the BODC flag denoting suspect value; the data values will not be altered.
The following types of irregularity, each relying on visual detection in the plot, are amongst those which may be flagged as suspect:
If a large percentage of the data is affected by irregularities then a Problem Report will be written rather than flagging the individual suspect values. Problem Reports are also used to highlight irregularities seen in the graphical data presentations.
Inconsistencies between the characteristics of the data set and those of its neighbours are sought and, where necessary, documented. This covers inconsistencies such as the following:
This intrinsic and extrinsic screening of the parameter values seeks to confirm the qualifying information and the source laboratory's comments on the series. In screening and collating information, every care is taken to ensure that errors of BODC making are not introduced.
No Project Information held for the Series
Cruise Name | JC086 |
Departure Date | 2013-05-06 |
Arrival Date | 2013-05-26 |
Principal Scientist(s) | Colin R Griffiths (Scottish Association for Marine Science) |
Ship | RRS James Cook |
Complete Cruise Metadata Report is available here
Station Name | Extended Ellett Line |
Category | Offshore route/traverse |
The Extended Ellett Line is a hydrographic transect consisting of 64 individual fixed stations which have been occupied, typically on an annual basis, since September 1996. The Line runs from the south of Iceland, across the Iceland Basin to the outcrop of Rockall, and across the Rockall Trough to the north west coast of Scotland (see map). CTD dips and associated water sampling for the analysis of nutrients are routinely performed during each station occupation.
The Extended Ellett Line augments the original Ellett Line time series - a shorter repeated transect which encompassed those stations between Rockall and Scotland. Work on the Ellett Line was typically carried out at least once a year between 1975 and 1996.
Map produced using the GEBCO Digital Atlas
The white triangles indicate the nominal positions of the Extended Ellett Line stations visited since September 1996. Measurements made along the Extended Ellett Line lie within a box bounded by co-ordinates 56° N, 21° W at the south west corner and 65° N, 6° W at the north east corner.
Listed below are nominal details of the standard hydrographic stations that form the Extended Ellett Line. The majority of these stations have been sampled since the outset, although several have been added more recently.
Station | Latitude | Longitude | Depth | Range |
---|---|---|---|---|
IB23S | 63.318 N | 20.210 W | 125 m | - |
IB22S | 63.217 N | 20.067 W | 660 m | 0.0 nm |
IB21S | 63.133 N | 19.917 W | 1030 m | 6.5 nm |
IB20S | 62.917 N | 19.550 W | 1415 m | 16.4 nm |
IB19S | 62.667 N | 19.667 W | 1500 m | 16.0 nm |
IB18S | 62.333 N | 19.833 W | 1800 m | 16.0 nm |
IB17 | 62.000 N | 20.000 W | 1700 m | 20.6 nm |
IB16A | 61.750 N | 20.000 W | 1797 m | - |
IB16 | 61.500 N | 20.000 W | 2000 m | 30.1 nm |
IB15 | 61.250 N | 20.000 W | 2375 m | 15.0 nm |
IB14 | 61.000 N | 20.000 W | 2400 m | 15.0 nm |
IB13A | 60.750 N | 20.000 W | 2500 m | - |
IB13 | 60.500 N | 20.000 W | 2500 m | 30.1 nm |
IB12A | 60.250 N | 20.000 W | 2600 m | - |
IB12 | 60.000 N | 20.000 W | 2700 m | 30.1 nm |
IB11A | 59.833 N | 19.500 W | 2700 m | - |
IB11 | 59.667 N | 19.117 W | 2680 m | 33.3 nm |
IB10 | 59.400 N | 18.417 W | 2420 m | 26.7 nm |
IB9 | 59.333 N | 18.233 W | 1910 m | 6.9 nm |
IB8 | 59.200 N | 17.883 W | 1540 m | 13.4 nm |
IB7 | 59.117 N | 17.667 W | 1000 m | 8.3 nm |
IB6 | 58.950 N | 17.183 W | 850 m | 18.0 nm |
IB5 | 58.883 N | 17.000 W | 1150 m | 7.0 nm |
IB4A | 58.667 N | 16.500 W | 1170 m | - |
IB4 | 58.500 N | 16.000 W | 1210 m | 38.8 nm |
IB3 | 58.250 N | 15.333 W | 680 m | 25.8 nm |
IB2 | 57.950 N | 14.583 W | 480 m | 29.9 nm |
IB1 | 57.667 N | 13.900 W | 160 m | 27.7 nm |
A | 57.583 N | 13.633 W | 130 m | 10.0 nm |
B | 57.567 N | 13.333 W | 210 m | 9.7 nm |
C | 57.550 N | 13.000 W | 330 m | 10.8 nm |
D | 57.542 N | 12.867 W | 1000 m | 4.3 nm |
E | 57.533 N | 12.633 W | 1658 m | 7.6 nm |
F | 57.508 N | 12.250 W | 1817 m | 12.5 nm |
G | 57.492 N | 11.850 W | 1812 m | 13.0 nm |
H | 57.483 N | 11.533 W | 2020 m | 10.3 nm |
I | 57.467 N | 11.317 W | 750 m | 7.0 nm |
J | 57.450 N | 11.083 W | 550 m | 7.6 nm |
K | 57.400 N | 10.867 W | 850 m | 7.6 nm |
L | 57.367 N | 10.667 W | 2076 m | 6.8 nm |
M | 57.300 N | 10.383 W | 2340 m | 10.1 nm |
N | 57.233 N | 10.050 W | 2100 m | 11.5 nm |
O | 57.150 N | 9.700 W | 1900 m | 12.4 nm |
P | 57.100 N | 9.417 W | 1050 m | 9.7 nm |
Q | 57.050 N | 9.217 W | 350 m | 7.2 nm |
Q1 | 57.075 N | 9.317 W | 800 m | - |
R | 57.000 N | 9.000 W | 135 m | 7.7 nm |
S | 56.950 N | 8.783 W | 125 m | 7.7 nm |
15G | 56.883 N | 8.500 W | 125 m | 10.1 nm |
T | 56.837 N | 8.333 W | 120 m | 6.1 nm |
14G | 56.808 N | 8.167 W | 115 m | 5.7 nm |
13G | 56.783 N | 8.000 W | 110 m | 5.7 nm |
12G | 56.758 N | 7.833 W | 80 m | 5.7 nm |
11G | 56.733 N | 7.667 W | 55 m | 5.7 nm |
10G | 56.733 N | 7.500 W | 220 m | 5.5 nm |
9G | 56.733 N | 7.333 W | 160 m | 5.5 nm |
8G | 56.733 N | 7.167 W | 175 m | 5.5 nm |
7G | 56.733 N | 7.000 W | 145 m | 5.5 nm |
6G | 56.733 N | 6.750 W | 35 m | 8.2 nm |
5G | 56.733 N | 6.600 W | 75 m | 4.9 nm |
4G | 56.733 N | 6.450 W | 115 m | 4.9 nm |
3G | 56.708 N | 6.367 W | 75 m | 3.1 nm |
2G | 56.683 N | 6.283 W | 40 m | 3.2 nm |
1G | 56.667 N | 6.133 W | 190 m | 5.0 nm |
BODC Cruise Identifier | Cruise Dates | Ship |
---|---|---|
D223A | 28 September-21 October 1996 | RRS Discovery |
D230 | 7 August-17 September 1997 | RRS Discovery |
D233 | 23 April-1 June 1998 | RRS Discovery |
D242 | 7 September-6 October 1999 | RRS Discovery |
D245 * | 27 January-20 February 2000 | RRS Discovery |
0700S * | 8-22 May 2000 | FRV Scotia |
D253 | 4 May-20 June 2001 | RRS Discovery |
0703S * | 15 April-5 May 2003 | FRV Scotia |
PO300_2 * | 19 July-6 August 2003 | RRS Poseidon |
PO314 | 11 July-23 July 2004 | RV Poseidon |
CD176 | 6 October-1 November 2005 | RRS Charles Darwin |
D312 | 11-31 October 2006 | RRS Discovery |
D321A | 24 July-23 August 2007 | RRS Discovery |
D321B | 24 August-9 September 2007 | RRS Discovery |
0508S * | 6-25 May 2008 | FRV Scotia |
D340A | 10-25 June 2009 | RRS Discovery |
D351 | 10-28 May 2010 | RRS Discovery |
D365 | 13 May-02 June 2011 | RRS Discovery |
D379 | 31 July-17 August 2012 | RRS Discovery |
JC086 | 6-26 May 2013 | RRS James Cook |
JR302 | 6 June-22 July 2014 | RRS James Clark Ross |
DY031 | 29 May- 17 June 2015 | RRS Discovery |
DY052 | 6-25 June 2016 | RRS Discovery |
* These cruises only surveyed the original hydrographic section between Scotland and Rockall.
Other Series linked to this Fixed Station for this cruise - 1220049 1220050 1220062 1220074 1220086 1220098 1220105 1220117 1220129 1220130 1220142 1220154 1220166 1220178 1220191 1220209 1220210 1220222 1220234 1220246 1220258 1220271 1220283 1220295 1220302 1220314 1220326 1220338 1220351 1220363 1220375 1220387 1220399 1220406 1220418 1220431 1220443 1220455 1220467 1220479 1220523 1220535 1220572 1220584 1220596 1220603 1220615 1220627 1220640 1220652 1220664 1220676 1220707 1220719 1220720 1220732 1220744 1220756
Other Cruises linked to this Fixed Station (with the number of series) - 0508S (29) 0700S (20) 0703S (20) CD176 (40) D223A (22) D230 (33) D233 (25) D242 (45) D245 (25) D253 (41) D312 (51) D321 (D321A) (12) D321B (59) D340A (58) D351 (59) D365 (63) D379 (98) JC086 (58) JR20140531 (JR302) (75) PO300_2 (31) PO314 (53)
Station Name | Ellett Line/Extended Ellett Line Station 6G |
Category | Offshore location |
Latitude | 56° 43.98' N |
Longitude | 6° 45.00' W |
Water depth below MSL | 35.0 m |
Station 6G is one of the fixed CTD stations, which together form The Extended Ellett Line. The line lies between Iceland and the Sound of Mull (Scotland) crossing the Iceland Basin and Rockall Trough via the outcrop of Rockall. As part of this initiative, CTD dips, together with associated discrete sampling of the water column, have typically been carried out annually at this station since September 1996.
Prior to September 1996, Station 6G was part of a shorter repeated survey section, consisting of 35 fixed stations, known as The Ellett Line (originally termed the Anton Dohrn Seamount Section). This line incorporated those stations across the Rockall Trough and Scottish shelf between Rockall and the Sound of Mull and was visited at regular intervals (usually at least once a year) between 1975 and January 1996. During this period Station 6G was also referred to as Station C4.
Other Cruises linked to this Fixed Station (with the number of series) - CD176 (1) CD44 (1) CD92B (2) CH1/85 (1) CH10/81 (1) CH10/84 (1) CH101B (1) CH103 (1) CH105 (1) CH11/77 (1) CH11/83 (1) CH110 (1) CH112 (1) CH114 (1) CH116 (1) CH11B/78 (1) CH11D/78 (1) CH120 (1) CH124 (1) CH13/79 (1) CH14 (1) CH14B/78 (1) CH15/80 (1) CH15/81 (1) CH16/79 (1) CH2/78 (1) CH2/81 (1) CH2/82 (1) CH2/84 (1) CH22 (1) CH25 (1) CH30 (1) CH4/77 (1) CH4/80 (1) CH4/85 (1) CH5A/76 (1) CH6/78 (1) CH63_2 (1) CH67A (1) CH6A/81 (1) CH6B/77 (1) CH7/79 (1) CH71A (1) CH74A_1 (1) CH75B (1) CH7A/82 (1) CH7B/83 (1) CH8/85 (1) CH81 (1) CH86B (1) CH89B (1) CH9 (1) CH9/78 (1) CH97 (1) CH9B/80 (1) D180 (1) D245 (1) D312 (1) D321B (1) D340A (1) D351 (1) D365 (1) D379 (1) DSK1/86 (1) DY031 (1) FR13/85 (1) FR18/87 (1) FR7B/86 (1) FR8/86 (1) JR20140531 (JR302) (1) LF1/89 (1) LF2/89 (1) PO300_2 (1) PO314 (1)
Station Name | Ellett Line |
Category | Offshore route/traverse |
The Ellett Line is a hydrographic transect consisting of 35 individual fixed stations which were occupied, usually at least once a year, between 1975 and 1996. The time series is named after the scientist David Ellett, who coordinated the survey work at Dunstaffnage Marine Laboratory (DML), near Oban. The transect ran between the north west coast of Scotland to the small outcrop of Rockall, via the Anton Dohrn Seamount - a prominent bathymetric feature in the Rockall Trough (see map). STD/CTD dips and associated water sampling for the analysis of nutrients were routinely performed during each station occupation.
In 1996 the transect was lengthened to incorporate new additional fixed stations crossing the Iceland Basin from Rockall to Iceland. This transect, which is still routinely occupied annually, is now known as the Extended Ellett Line and is a collaborative effort between scientists at Dunstaffnage Marine Laboratory and the Southampton site of the National Oceanography Centre (NOC).
Map produced using the GEBCO Digital Atlas
The white triangles indicate the nominal positions of the Ellett Line stations (1975- 1996). Measurements made along the Ellett Line lie within a box bounded by co-ordinates 56° 40.02' N, 13° 42.0' W at the south west corner and 57° 37.2' N, 6° 7.98' W at the north east corner.
Listed below are nominal details of the standard hydrographic stations that formed the Ellett Line between 1975 and January 1996.
Station | Latitude | Longitude | Depth | Range |
---|---|---|---|---|
A | 57.583 N | 13.633 W | 130 m | 10.0 nm |
B | 57.567 N | 13.333 W | 210 m | 9.7 nm |
C | 57.550 N | 13.000 W | 330 m | 10.8 nm |
D | 57.542 N | 12.867 W | 1000 m | 4.3 nm |
E | 57.533 N | 12.633 W | 1658 m | 7.6 nm |
F | 57.508 N | 12.250 W | 1817 m | 12.5 nm |
G | 57.492 N | 11.850 W | 1812 m | 13.0 nm |
H | 57.483 N | 11.533 W | 2020 m | 10.3 nm |
I | 57.467 N | 11.317 W | 750 m | 7.0 nm |
J | 57.450 N | 11.083 W | 550 m | 7.6 nm |
K | 57.400 N | 10.867 W | 850 m | 7.6 nm |
L | 57.367 N | 10.667 W | 2076 m | 6.8 nm |
M | 57.300 N | 10.383 W | 2340 m | 10.1 nm |
N | 57.233 N | 10.050 W | 2100 m | 11.5 nm |
O | 57.150 N | 9.700 W | 1900 m | 12.4 nm |
P | 57.100 N | 9.417 W | 1050 m | 9.7 nm |
Q | 57.050 N | 9.217 W | 350 m | 7.2 nm |
R | 57.000 N | 9.000 W | 135 m | 7.7 nm |
S | 56.950 N | 8.783 W | 125 m | 7.7 nm |
15G | 56.883 N | 8.500 W | 125 m | 10.1 nm |
T | 56.837 N | 8.333 W | 120 m | 6.1 nm |
14G | 56.808 N | 8.167 W | 115 m | 5.7 nm |
13G | 56.783 N | 8.000 W | 110 m | 5.7 nm |
12G | 56.758 N | 7.833 W | 80 m | 5.7 nm |
11G | 56.733 N | 7.667 W | 55 m | 5.7 nm |
10G | 56.733 N | 7.500 W | 220 m | 5.5 nm |
9G | 56.733 N | 7.333 W | 160 m | 5.5 nm |
8G | 56.733 N | 7.167 W | 175 m | 5.5 nm |
7G | 56.733 N | 7.000 W | 145 m | 5.5 nm |
6G | 56.733 N | 6.750 W | 35 m | 8.2 nm |
5G | 56.733 N | 6.600 W | 75 m | 4.9 nm |
4G | 56.733 N | 6.450 W | 115 m | 4.9 nm |
3G | 56.708 N | 6.367 W | 75 m | 3.1 nm |
2G | 56.683 N | 6.283 W | 40 m | 3.2 nm |
1G | 56.667 N | 6.133 W | 190 m | 5.0 nm |
BODC Cruise Identifier | Cruise Dates | Ship |
---|---|---|
CH3/75 | 4-13 March 1975 | RRS Challenger |
CH7A/75 | 1-6 May 1975 | RRS Challenger |
CH10A/75 | 4-10 July 1975 | RRS Challenger |
CH12A/75 | 26 August-2 September 1975 | RRS Challenger |
CH14A/75 | 7-12 November 1975 | RRS Challenger |
CH5A/76 | 29 March-5 April 1976 | RRS Challenger |
CH8/76 | 19 May-1 June 1976 | RRS Challenger |
CH12/76 | 4-15 August 1976 | RRS Challenger |
CH15/76 | 7-16 October 1976 | RRS Challenger |
CH17/76 | 7-20 December 1976 | RRS Challenger |
CH4/77 | 25 February-11 March 1977 | RRS Challenger |
CH6B/77 | 14-19 April 1977 | RRS Challenger |
CH10/77 | 29 June-10 July 1977 | RRS Challenger |
CH11/77 | 12-26 July 1977 | RRS Challenger |
CH13/77 | 20 August-3 September 1977 | RRS Challenger |
CH2/78 | 30 January-13 February 1978 | RRS Challenger |
CH6/78 | 11-21 April 1978 | RRS Challenger |
CH9/78 | 31 May-10 June 1978 | RRS Challenger |
CH11B/78 | 29 July-12 August 1978 | RRS Challenger |
CH11D/78 | 3-17 September 1978 | RRS Challenger |
CH14B/78 | 4-11 November 1978 | RRS Challenger |
CH7/79 | 10-23 May 1979 | RRS Challenger |
S5/79 | 19 June-2 July 1979 | RRS Shackleton |
CH13/79 | 11-16 September 1979 | RRS Challenger |
CH16/79 | 28 October-11 November 1979 | RRS Challenger |
CH4/80 | 26 February-7 March 1980 | RRS Challenger |
CH7/80 | 21 April-6 May 1980 | RRS Challenger |
CH2/81 | 26 January-4 February 1981 | RRS Challenger |
CH6A/81 CH6B/81 | 6-25 April 1981 | RRS Challenger |
CH10/81 | 4-14 July 1981 | RRS Challenger |
CH15/81 | 6-20 October 1981 | RRS Challenger |
CH7A/82 CH7B/82 | 26 April-16 May 1982 | RRS Challenger |
CH15/82 | 16-30 October 1982 | RRS Challenger |
CH7B/83 | 23 May-2 June 1983 | RRS Challenger |
CH11/83 | 10-24 August 1983 | RRS Challenger |
CH2/84 | 23 June-8 July 1984 | RRS Challenger |
CH10/84 | 16 November-6 December 1984 | RRS Challenger |
CH1/85 | 20 January-5 February 1985 | RRS Challenger |
CH4/85 | 2-16 May 1985 | RRS Challenger |
CH8/85 | 14-28 August 1985 | RRS Challenger |
CH9 | 8-22 January 1987 | RRS Challenger |
CH14 | 24 April-7 May 1987 | RRS Challenger |
CH22 | 23 November-5 December 1987 | RRS Challenger |
CH25 | 24 February-7 March 1988 | RRS Challenger |
CH30 | 6-23 June 1988 | RRS Challenger |
D180 | 20 January-4 February 1989 | RRS Discovery |
LF1/89 | 5-11 May 1989 | RV Lough Foyle |
LF2/89 | 4-10 August 1989 | RV Lough Foyle |
CD44 | 24 November-2 December 1989 | RRS Charles Darwin |
CH67A | 21-29 June 1990 | RRS Challenger |
CH71A | 29 August-5 September 1990 | RRS Challenger |
CH75B | 23 February-3 March 1991 | RRS Challenger |
CH81 | 1-8 July 1991 | RRS Challenger |
CH97 | 25 September-6 October 1992 | RRS Challenger |
CH101B | 13-20 March 1993 | RRS Challenger |
CH103 | 12-24 May 1993 | RRS Challenger |
CH105 | 3-16 September 1993 | RRS Challenger |
CH110 | 10-20 March 1994 | RRS Challenger |
CH112 | 28 April-13 May 1994 | RRS Challenger |
CH114 | 15-29 August 1994 | RRS Challenger |
CH116 | 17-29 November 1994 | RRS Challenger |
CD92B | 13 April-2 May 1995 | RRS Charles Darwin |
CH120 | 18 July-6 August 1995 | RRS Challenger |
CH124 | 8-27 January 1996 | RRS Challenger |
Other Series linked to this Fixed Station for this cruise - 1220302 1220314 1220326 1220338 1220351 1220363 1220375 1220387 1220399 1220406 1220418 1220431 1220443 1220455 1220467 1220479 1220523 1220535 1220572 1220584 1220596 1220603 1220615 1220627 1220640 1220652 1220664 1220676 1220707 1220719 1220720 1220732 1220744 1220756
Other Cruises linked to this Fixed Station (with the number of series) - 0508S (29) 0700S (20) 0703S (20) CD176 (32) CD44 (34) CD92B (47) CH1/85 (19) CH10/77 (3) CH10/81 (21) CH10/84 (22) CH101B (13) CH103 (37) CH105 (34) CH10A/75 (15) CH11/77 (28) CH11/83 (35) CH110 (19) CH112 (35) CH114 (31) CH116 (25) CH11B/78 (26) CH11D/78 (14) CH120 (28) CH124 (32) CH12A/75 (3) CH13/77 (19) CH13/79 (17) CH14 (29) CH14A/75 (21) CH14B/78 (17) CH15/80 (8) CH15/81 (16) CH16/79 (13) CH2/78 (32) CH2/81 (13) CH2/82 (4) CH2/84 (29) CH22 (14) CH25 (18) CH3/83 (1) CH30 (23) CH4/77 (19) CH4/80 (29) CH4/85 (30) CH5A/76 (18) CH6/78 (25) CH63_2 (5) CH67A (27) CH6A/81 (14) CH6B/77 (24) CH6B/81 (20) CH7/79 (18) CH7/80 (16) CH71A (32) CH74A_1 (13) CH75B (31) CH7A/75 (24) CH7A/82 (24) CH7B/82 (13) CH7B/83 (29) CH8/76 (27) CH8/85 (30) CH81 (30) CH86B (8) CH89B (9) CH9 (25) CH9/78 (22) CH97 (30) CH9B/80 (10) D180 (30) D223A (22) D230 (11) D233 (10) D242 (23) D245 (25) D253 (22) D312 (34) D321B (35) D340A (34) D351 (34) D365 (55) D379 (36) DSK1/86 (10) FR13/85 (12) FR13/87 (2) FR14B/87 (2) FR18/87 (11) FR7B/86 (6) FR8/86 (13) JC086 (34) JR20140531 (JR302) (37) LF1/89 (29) LF2/89 (30) PO300_2 (31) PO314 (30) S5/79 (8)
The following single character qualifying flags may be associated with one or more individual parameters with a data cycle:
Flag | Description |
---|---|
Blank | Unqualified |
< | Below detection limit |
> | In excess of quoted value |
A | Taxonomic flag for affinis (aff.) |
B | Beginning of CTD Down/Up Cast |
C | Taxonomic flag for confer (cf.) |
D | Thermometric depth |
E | End of CTD Down/Up Cast |
G | Non-taxonomic biological characteristic uncertainty |
H | Extrapolated value |
I | Taxonomic flag for single species (sp.) |
K | Improbable value - unknown quality control source |
L | Improbable value - originator's quality control |
M | Improbable value - BODC quality control |
N | Null value |
O | Improbable value - user quality control |
P | Trace/calm |
Q | Indeterminate |
R | Replacement value |
S | Estimated value |
T | Interpolated value |
U | Uncalibrated |
W | Control value |
X | Excessive difference |
The following single character qualifying flags may be associated with one or more individual parameters with a data cycle:
Flag | Description |
---|---|
0 | no quality control |
1 | good value |
2 | probably good value |
3 | probably bad value |
4 | bad value |
5 | changed value |
6 | value below detection |
7 | value in excess |
8 | interpolated value |
9 | missing value |
A | value phenomenon uncertain |